Fire Resistant Cable

Quality 0.6/1kV Copper PVC Insulated PVC Sheathed Fire Resistant Cable – Flexible Power Cable (VV-FR / NH-VVR) factory

0.6/1kV Copper PVC Insulated PVC Sheathed Fire Resistant Cable – Flexible Power Cable (VV-FR / NH-VVR)

0.6/1kV Copper PVC Insulated PVC Sheathed Fire Resistant Cable – Flexible Power Cable (VV-FR / NH-VVR) Product Overview The VV-FR / NH-VVR cable is a flexible, fire-resistant power cable rated at 0.6/1kV. It features copper conductor, PVC insulation, and PVC sheath with enhanced fire-resistant performance. Designed for critical power circuits where circuit integrity during fire is essential. Complies with IEC 60331 / BS 6387 (CWZ) fire resistance standards Key Specifications
Quality 0.6/1kV 3+1 Core Fire Resistant Cable | IEC 60331 FR XLPE Insulated Power Cable for Emergency Systems factory

0.6/1kV 3+1 Core Fire Resistant Cable | IEC 60331 FR XLPE Insulated Power Cable for Emergency Systems

0.6/1kV 3+1 Core Fire Resistant Cable | IEC 60331 FR XLPE Insulated Power Cable for Emergency Systems 1. Product Overview The 0.6/1kV 3+1 core fire resistant cable is designed to maintain circuit integrity during fire conditions, ensuring continuous power supply to critical systems such as fire alarms, emergency lighting, and evacuation equipment. Manufactured with high-quality copper conductors and fire-resistant insulation, this cable complies with IEC standards and is
Quality 0.6/1kV Fire Resistant Cable CU/LSZH/LSZH EN 60332-3-24 factory

0.6/1kV Fire Resistant Cable CU/LSZH/LSZH EN 60332-3-24

0.6/1kV Fire Resistant Cable CU/LSZH/LSZH EN 60332-3-24 Application A low-voltage fire-resistant power cable with LSZH insulation and sheath. The cable is widely used in places where fire safety is critical, such as commercial buildings, hospitals, airports,metro stations, shopping malls, schools and tec. Construction 1.Conductor : Class 1 or 2 copper conductor 2.Insulation:LSZH (Low Smoke Zero Halogen)3.Inner Sheath:LSZH (Low Smoke Zero Halogen)4. Outer Sheath:LSZH (Low
Quality Armoured Fire Resistant Cable 3+1 Core Cu/XLPE/PVC/SWA/PVC for Underground Application factory

Armoured Fire Resistant Cable 3+1 Core Cu/XLPE/PVC/SWA/PVC for Underground Application

Armoured Fire Resistant Cable 3+1 Core Cu/XLPE/PVC/SWA/PVC for Underground Application Description Electrical power cable with copper conductors, XLPE insulation, PVC bedding, galvanized steel wires armour (SWA) and PVC outer sheath Application Multi-core PVC cable with steel wire armour (SWA). Power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting. Cable Construction 1.Conductor : Compact
Quality Low Voltage Fire Resistant Cable 0.6/1kV with Copper Conductor and XLPE Insulation for Fire Safety Applications factory

Low Voltage Fire Resistant Cable 0.6/1kV with Copper Conductor and XLPE Insulation for Fire Safety Applications

Low Voltage Fire Rated Cable 0.6/1kV CU/XLPE/PE YJY N2X2Y This fire-resistant cable is designed for low-voltage power distribution systems where fire safety is critical, rated for 0.6/1kV applications. Applications Suitable for installation in cable ducts, underground applications, and exposed installations in various industrial and commercial environments. Construction Details Conductor: Class 1/Class 2 stranded copper conductor Refractory layer: Single-sided gold mica tape
Quality 450/750 Fire Resistant Control Cable CU/PVC/STW/PVC NYY NYBY  2-61 Cores factory

450/750 Fire Resistant Control Cable CU/PVC/STW/PVC NYY NYBY 2-61 Cores

450/750 Fire Resistant Control Cable CU/PVC/STW/PVC NYY NYBY 2-61 Cores APPLICATION This product is suitable for use in control, monitoring circuits, and protection circuits in circuits with a rated voltage of 450/750V and below CONSTRUCTION Conductor C ircular solid copper conductor (A) or circular stranded copper conductor (B) Insulation Polyvinyl chloride (PVC) Filler Polypropylene (PP) m esh f illing r ope Armouring (optional) Galvanized steel tape Outer sheath Polyvinyl
Quality Low Voltage Fire Resistant Cable 0.6/1kV with Copper Conductor and XLPE Insulation for Fire Safety Applications factory

Low Voltage Fire Resistant Cable 0.6/1kV with Copper Conductor and XLPE Insulation for Fire Safety Applications

Low Voltage Fire Rated Cable 0.6/1kV CU/XLPE/PE YJY N2X2Y This fire-resistant cable is designed for low-voltage power distribution systems where fire safety is critical, rated for 0.6/1kV applications. Applications Suitable for installation in cable ducts, underground applications, and exposed installations in various industrial and commercial environments. Construction Details Conductor: Class 1/Class 2 stranded copper conductor Refractory layer: Single-sided gold mica tape
Quality EAC Certified Fire Resistant Cable N2XH LSZH Environmental Protection Cable factory

EAC Certified Fire Resistant Cable N2XH LSZH Environmental Protection Cable

EAC Certified Fire Resistant Cable N2XH LSZH Environmental Protection Cable APPLICATION & CHARACTERISTICS Petrochemical processing units (reactor jackets, distillation columns) Steel mill conveyor systems (blast furnace zones, rolling mills) Aerospace engine compartment wiring CONSTRUCTION Conductor: Typically composed of high-purity copper or aluminum, annealed for flexibility and low resistance. Insulation: Cross-linked polyethylene (XLPE) insulation provides excellent
Quality Halogen-Free Flame-Resistant Cable NXXH N2XH-J N2XH-O factory

Halogen-Free Flame-Resistant Cable NXXH N2XH-J N2XH-O

Halogen-Free Flame-Resistant Cable NXXH N2XH-J N2XH-O APPLICATION & CHARACTERISTICS 1. N2XH Cable Series Core Applications : Petrochemical processing units (reactor jackets, distillation columns) Steel mill conveyor systems (blast furnace zones, rolling mills) Aerospace engine compartment wiring Technical Characteristics : Continuous service temperature: -40°C to +250°C Halogen-free flame retardant (IEC 60332-3C compliant) Oil/fuel resistance (per ASTM D471) Cross-linked
Quality 0.6/1kV Fire Resistant Power Cable CU/ XLPE/ PVC 07V-Z IEC 60332-3C  IEC 60331 factory

0.6/1kV Fire Resistant Power Cable CU/ XLPE/ PVC 07V-Z IEC 60332-3C IEC 60331

0.6/1kV Fire Resistant Power Cable CU/ XLPE/ PVC 07V-Z IEC 60332-3C IEC 60331 APPLICATION This product is suitable for use in line filling circuits rated voltage not exceeding 0.6/1kV for power transmission and distribution ‌ CONSTRUCTION Conductor: Class 1/ Class 2 stranded Copper conductor Refractory layer: Single sided gold mica tape Insulation: XLPE Filler ( options ): Polypropylene mesh tear rope or flame-retardant filling Outer sheath: Polyvinyl chloride (PVC) CHARA C
Quality Steel Tape Armoured STA Fire Retardant Cable PVC Sheathed Control Cable factory

Steel Tape Armoured STA Fire Retardant Cable PVC Sheathed Control Cable

Steel Tape Armoured STA Fire Resistant Flame Retardant PVC Sheathed Control Cable Application ‌Industrial Plants ‌ Power Distribution Systems ‌ ‌High-Risk Buildings ‌Transportation Infrastructure ‌ ‌Hazardous Environments ‌ ‌Emergency Systems ‌ Construction Conductor: Solid or Stranded Copper Conductor Insualtion: XLPE Inner Sheath: PVC Armor: Steel Tape Sheath: Flame Retardant PVC Description Rated voltage 450/750V or less,The control cable can be made as flame retardant
Quality CE Certification Fire Resistant Cable 450V 750V Fire Rated Flexible Cable factory

CE Certification Fire Resistant Cable 450V 750V Fire Rated Flexible Cable

CE Certification Fire Resistant Cable Flexible Cable/Rated voltage 450/750V Application For system connection wire of control, signal, protection or measuring with rated voltage up to and including 450/750KV. Construction Conductor: Plain annealed copper (class 2, normal stranded or compact stranded) Fire barrier: Mica tape Insulation: XLPE Filler, binder and inner covering: PP, PET, LSZH Outer sheath: LSZH Technical parameters Single Core Cross section of conductor(mm²)
Quality Medium Voltage Fire Safety Cables With PVC Sheathed Stranded Conductors factory

Medium Voltage Fire Safety Cables With PVC Sheathed Stranded Conductors

Medium Voltage Fire Resistant Cable with PVC Sheathed Stranded Conductors Application Fire resistant cables can be used in several critical buildings where safety against fire is mandatory to reduce the risk of death as: Hospitals & Old people’shomes. Schools & Recreational buildings. Museums & Historical places. Undergrounds & Tunnels. Railways & Airports. Shopping Centers & Malls. Theatres & Cinemas. Hotels & Offices. High-rise buildings Construction Stranded co
Quality Low Smoke Zero Halogen LSZH Fire Resistant Cable Fiberglass Braid Wire Custom Length factory

Low Smoke Zero Halogen LSZH Fire Resistant Cable Fiberglass Braid Wire Custom Length

Low Smoke Zero Halogen Fire Resistant Cable Fiberglass Braid Wire Application Fire-resistant cables are designed to maintain circuit integrity and continue operating during fire emergencies, ensuring critical systems remain functional. These cables are essential in environments where fire safety and uninterrupted power supply are priorities Construction Conductor: Plain annealed copper (class 2, normal stranded or compact stranded) Fire barrier: Mica tape Insulation: XLPE
Quality XLPE Insulation 4 core heat resistant cable Flame Retardant Power Cable OEM factory

XLPE Insulation 4 core heat resistant cable Flame Retardant Power Cable OEM

XLPE Insulation Fire Resistant Cable Flame Retardant sheath Power cable 4 Core Application Fire resistant cables can be used in several critical buildings where safety against fire is mandatory to reduce the risk of death as: Hospitals & Old people’shomes. Schools & Recreational buildings. Museums & Historical places. Undergrounds & Tunnels. Railways & Airports. Shopping Centers & Malls. Theatres & Cinemas. Hotels & Offices. High-rise buildings Construction C ondu
Quality Copper Conductor STA Armoured Fire Protection Cable XLPE Insulated PVC Sheathed factory

Copper Conductor STA Armoured Fire Protection Cable XLPE Insulated PVC Sheathed

Copper Conductor STA Armoured Fire Resistant Cable XLPE Insulated PVC Sheathed Cable Application Our cables have been widely used in the energy field (power stations, nuclear power posts, urban and rural power grids, coal mines, petrochemicals, etc.), transportation field (civil aviation, nuclear power plant) network, coal mine, petrochemicals, etc.), transportation field (civil aviation airports, railroads and urban rail transportation, ships and transportation field (civil
Quality Steel Wire Armoured Fire Resistant Cable 0.6 1.0kV Two Core Heat Proof Electrical Cable factory

Steel Wire Armoured Fire Resistant Cable 0.6 1.0kV Two Core Heat Proof Electrical Cable

Steel Wire Armoured Fire Resistant Cable 0.6/1.0kV Two Core Application Fire resistant cables can be used in several critical buildings where safety against fire is mandatory to reduce the risk of death as: Hospitals & Old people’shomes. Schools & Recreational buildings. Museums & Historical places. Undergrounds & Tunnels. Railways & Airports. Shopping Centers & Malls. Theatres & Cinemas. Hotels & Offices. High-rise buildings Construction Conductor: Plain Annealed
Quality 1 Core 0.6kv 1kv Fire Proof Cable Copper Conductor XLPE Insulated Fire Resistant Wire factory

1 Core 0.6kv 1kv Fire Proof Cable Copper Conductor XLPE Insulated Fire Resistant Wire

Single Core 0.6/1kv Fire Resistant Cable Copper Conductor XLPE Insulated APPLICATION Standard fire resistant cables for use primarily in fire detection, fire alarm, voice alarm, and emergency lighting circuits. These cables are designed to continue to operate for a period of time in a fire situation. ‘Standard’ fire resistance is recommended for general use. Construction Conductor: Plain annealed copper (class 2, normal stranded or compact stranded) Fire barrier: Mica tape
Quality 0.6 KV 1KV Halogen Free Fire Resistant Cable Indoor Outdoor Electrical Cable factory

0.6 KV 1KV Halogen Free Fire Resistant Cable Indoor Outdoor Electrical Cable

0.6/1KV Fireproof Insulation Fire Resistant Cable Indoor / Outdoor Electrical Cable Application It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable. Advantages - halogen-free, no