کابل مقاوم در برابر آتش
0.6/1kV کابل مقاوم در آتش مس PVC عایق بندی شده PVC پوشانده شده ️ کابل برق انعطاف پذیر (VV-FR / NH-VVR)
0.6/1kV Copper PVC Insulated PVC Sheathed Fire Resistant Cable – Flexible Power Cable (VV-FR / NH-VVR) Product Overview The VV-FR / NH-VVR cable is a flexible, fire-resistant power cable rated at 0.6/1kV. It features copper conductor, PVC insulation, and PVC sheath with enhanced fire-resistant performance. Designed for critical power circuits where circuit integrity during fire is essential. Complies with IEC 60331 / BS 6387 (CWZ) fire resistance standards Key Specifications
0.6/1kV 3+1 کابل ضد آتش هسته ای IEC 60331 FR XLPE کابل برق عایق برای سیستم های اضطراری
0.6/1kV 3+1 Core Fire Resistant Cable | IEC 60331 FR XLPE Insulated Power Cable for Emergency Systems 1. Product Overview The 0.6/1kV 3+1 core fire resistant cable is designed to maintain circuit integrity during fire conditions, ensuring continuous power supply to critical systems such as fire alarms, emergency lighting, and evacuation equipment. Manufactured with high-quality copper conductors and fire-resistant insulation, this cable complies with IEC standards and is
کابل مقاوم در برابر آتش 0.6/1 کیلو ولت مس/LSZH/LSZH مطابق با EN 60332-3-24
0.6/1kV Fire Resistant Cable CU/LSZH/LSZH EN 60332-3-24 Application A low-voltage fire-resistant power cable with LSZH insulation and sheath. The cable is widely used in places where fire safety is critical, such as commercial buildings, hospitals, airports,metro stations, shopping malls, schools and tec. Construction 1.Conductor : Class 1 or 2 copper conductor 2.Insulation:LSZH (Low Smoke Zero Halogen)3.Inner Sheath:LSZH (Low Smoke Zero Halogen)4. Outer Sheath:LSZH (Low
کابل ضد آتش زرهی 3+1 هسته Cu/XLPE/PVC/SWA/PVC برای کاربرد زیرزمینی
Armoured Fire Resistant Cable 3+1 Core Cu/XLPE/PVC/SWA/PVC for Underground Application Description Electrical power cable with copper conductors, XLPE insulation, PVC bedding, galvanized steel wires armour (SWA) and PVC outer sheath Application Multi-core PVC cable with steel wire armour (SWA). Power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting. Cable Construction 1.Conductor : Compact
کابل مقاوم در برابر حریق ولتاژ پایین 0.6/1 کیلو ولت با هادی مسی و عایق XLPE برای کاربردهای ایمنی در برابر حریق
Low Voltage Fire Rated Cable 0.6/1kV CU/XLPE/PE YJY N2X2Y This fire-resistant cable is designed for low-voltage power distribution systems where fire safety is critical, rated for 0.6/1kV applications. Applications Suitable for installation in cable ducts, underground applications, and exposed installations in various industrial and commercial environments. Construction Details Conductor: Class 1/Class 2 stranded copper conductor Refractory layer: Single-sided gold mica tape
450/750 Fire Resistant Control Cable CU/PVC/STW/PVC NYY NYBY 2-61 Cores
450/750 Fire Resistant Control Cable CU/PVC/STW/PVC NYY NYBY 2-61 Cores APPLICATION This product is suitable for use in control, monitoring circuits, and protection circuits in circuits with a rated voltage of 450/750V and below CONSTRUCTION Conductor C ircular solid copper conductor (A) or circular stranded copper conductor (B) Insulation Polyvinyl chloride (PVC) Filler Polypropylene (PP) m esh f illing r ope Armouring (optional) Galvanized steel tape Outer sheath Polyvinyl
کابل مقاوم در برابر حریق ولتاژ پایین 0.6/1 کیلو ولت با هادی مسی و عایق XLPE برای کاربردهای ایمنی در برابر حریق
Low Voltage Fire Rated Cable 0.6/1kV CU/XLPE/PE YJY N2X2Y This fire-resistant cable is designed for low-voltage power distribution systems where fire safety is critical, rated for 0.6/1kV applications. Applications Suitable for installation in cable ducts, underground applications, and exposed installations in various industrial and commercial environments. Construction Details Conductor: Class 1/Class 2 stranded copper conductor Refractory layer: Single-sided gold mica tape
EAC Certified Fire Resistant Cable N2XH LSZH Environmental Protection Cable
EAC Certified Fire Resistant Cable N2XH LSZH Environmental Protection Cable APPLICATION & CHARACTERISTICS Petrochemical processing units (reactor jackets, distillation columns) Steel mill conveyor systems (blast furnace zones, rolling mills) Aerospace engine compartment wiring CONSTRUCTION Conductor: Typically composed of high-purity copper or aluminum, annealed for flexibility and low resistance. Insulation: Cross-linked polyethylene (XLPE) insulation provides excellent
کابل ضد شعله بدون هالوجن NXXH N2XH-J N2XH-O
Halogen-Free Flame-Resistant Cable NXXH N2XH-J N2XH-O APPLICATION & CHARACTERISTICS 1. N2XH Cable Series Core Applications : Petrochemical processing units (reactor jackets, distillation columns) Steel mill conveyor systems (blast furnace zones, rolling mills) Aerospace engine compartment wiring Technical Characteristics : Continuous service temperature: -40°C to +250°C Halogen-free flame retardant (IEC 60332-3C compliant) Oil/fuel resistance (per ASTM D471) Cross-linked
کابل قدرت مقاوم در برابر آتش 0.6/1 کیلو ولت CU/ XLPE/ PVC 07V-Z IEC 60332-3C IEC 60331
0.6/1kV Fire Resistant Power Cable CU/ XLPE/ PVC 07V-Z IEC 60332-3C IEC 60331 APPLICATION This product is suitable for use in line filling circuits rated voltage not exceeding 0.6/1kV for power transmission and distribution CONSTRUCTION Conductor: Class 1/ Class 2 stranded Copper conductor Refractory layer: Single sided gold mica tape Insulation: XLPE Filler ( options ): Polypropylene mesh tear rope or flame-retardant filling Outer sheath: Polyvinyl chloride (PVC) CHARA C
کابل ضد آتش با نوار فولادی STA کابلی کنترل با پوشش PVC
Steel Tape Armoured STA Fire Resistant Flame Retardant PVC Sheathed Control Cable Application Industrial Plants Power Distribution Systems High-Risk Buildings Transportation Infrastructure Hazardous Environments Emergency Systems Construction Conductor: Solid or Stranded Copper Conductor Insualtion: XLPE Inner Sheath: PVC Armor: Steel Tape Sheath: Flame Retardant PVC Description Rated voltage 450/750V or less,The control cable can be made as flame retardant
گواهینامه CE کابل ضد آتش 450 ولت 750 ولت کابل انعطاف پذیر با درجه حرارت آتش
CE Certification Fire Resistant Cable Flexible Cable/Rated voltage 450/750V Application For system connection wire of control, signal, protection or measuring with rated voltage up to and including 450/750KV. Construction Conductor: Plain annealed copper (class 2, normal stranded or compact stranded) Fire barrier: Mica tape Insulation: XLPE Filler, binder and inner covering: PP, PET, LSZH Outer sheath: LSZH Technical parameters Single Core Cross section of conductor(mm²)
کابل های ایمنی آتش سوزی با ولتاژ متوسط با هادی های رشته ای پوشیده از PVC
Medium Voltage Fire Resistant Cable with PVC Sheathed Stranded Conductors Application Fire resistant cables can be used in several critical buildings where safety against fire is mandatory to reduce the risk of death as: Hospitals & Old people’shomes. Schools & Recreational buildings. Museums & Historical places. Undergrounds & Tunnels. Railways & Airports. Shopping Centers & Malls. Theatres & Cinemas. Hotels & Offices. High-rise buildings Construction Stranded co
کم دود صفر هالوجن LSZH کابل مقاوم در برابر آتش فیبرگلاس تراش سیم سفارشی طول
Low Smoke Zero Halogen Fire Resistant Cable Fiberglass Braid Wire Application Fire-resistant cables are designed to maintain circuit integrity and continue operating during fire emergencies, ensuring critical systems remain functional. These cables are essential in environments where fire safety and uninterrupted power supply are priorities Construction Conductor: Plain annealed copper (class 2, normal stranded or compact stranded) Fire barrier: Mica tape Insulation: XLPE
XLPE عایق 4 هسته کابل مقاوم به گرما شعله بازدارنده کابل برق OEM
XLPE Insulation Fire Resistant Cable Flame Retardant sheath Power cable 4 Core Application Fire resistant cables can be used in several critical buildings where safety against fire is mandatory to reduce the risk of death as: Hospitals & Old people’shomes. Schools & Recreational buildings. Museums & Historical places. Undergrounds & Tunnels. Railways & Airports. Shopping Centers & Malls. Theatres & Cinemas. Hotels & Offices. High-rise buildings Construction C ondu
هادی مس STA کابل محافظت از آتش زره ای XLPE عایق بندی شده PVC پوشه شده
Copper Conductor STA Armoured Fire Resistant Cable XLPE Insulated PVC Sheathed Cable Application Our cables have been widely used in the energy field (power stations, nuclear power posts, urban and rural power grids, coal mines, petrochemicals, etc.), transportation field (civil aviation, nuclear power plant) network, coal mine, petrochemicals, etc.), transportation field (civil aviation airports, railroads and urban rail transportation, ships and transportation field (civil
سیم فولادی کابلی مقاوم در آتش 0.6 1.0kV دو هسته ای کابلی ضد گرما
Steel Wire Armoured Fire Resistant Cable 0.6/1.0kV Two Core Application Fire resistant cables can be used in several critical buildings where safety against fire is mandatory to reduce the risk of death as: Hospitals & Old people’shomes. Schools & Recreational buildings. Museums & Historical places. Undergrounds & Tunnels. Railways & Airports. Shopping Centers & Malls. Theatres & Cinemas. Hotels & Offices. High-rise buildings Construction Conductor: Plain Annealed
1 هسته 0.6kv 1kv کابل ضد آتش کانکتور مس XLPE سیم ضد آتش عایق
Single Core 0.6/1kv Fire Resistant Cable Copper Conductor XLPE Insulated APPLICATION Standard fire resistant cables for use primarily in fire detection, fire alarm, voice alarm, and emergency lighting circuits. These cables are designed to continue to operate for a period of time in a fire situation. ‘Standard’ fire resistance is recommended for general use. Construction Conductor: Plain annealed copper (class 2, normal stranded or compact stranded) Fire barrier: Mica tape
0.6 KV 1KV کابل ضد آتش بدون هالوجن کابل برق در فضای باز
0.6/1KV Fireproof Insulation Fire Resistant Cable Indoor / Outdoor Electrical Cable Application It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable. Advantages - halogen-free, no