logo

Bare Conductor

Quality Stranded Aluminium Bare Conductor AAC ACSR AAAC Conductor For Overhead Transmission factory

Stranded Aluminium Bare Conductor AAC ACSR AAAC Conductor For Overhead Transmission

Stranded Bare Conductor Cable AAC ACSR AAAC Aluminum Cable Application These conductors are mainly used in urban areas for electricity transfer. Apart from that, these conductors are also extensively used in coastal area because of their corrosion resistance properties. Construction Code name Item Application AAC All-aluminium Conductor Mainly for overhead power transmission and primary and secondary distribution AAAC All Aluminimum Alloy Conductor ACSR Aluminium Conductor
Quality Bare All Aluminium Alloy Conductor Stranded AAAC AAC ACSR Overhead Line Conductor factory

Bare All Aluminium Alloy Conductor Stranded AAAC AAC ACSR Overhead Line Conductor

Overhead Bare Conductor All Aluminium Alloy Stranded AAAC,AAC,ACSR Cable AAC - All Aluminum Conductor Application This all aluminum conductor is a kind of aluminum product made through stranding aluminum wires. It is used for the electricity distribution lines with short span length and small load-carrying capability of the pole. The AAC provides reliable performance for overhead power transmission and distribution lines. This standard covers hard drawn circular aluminum
Quality ACSR Bare Aluminum Conductor Steel Reinforced 150mm Overhead BS215 Standard factory

ACSR Bare Aluminum Conductor Steel Reinforced 150mm Overhead BS215 Standard

ACSR Bare Conductor Steel Reinforced 150mm Overhead BS215 Standard Application ACSR (Aluminum Conductor Steel Reinforced) is a composite overhead cable combining aluminum strands for conductivity and a steel core for strength. Its key applications include: Overhead Power Transmission & Distribution High-Voltage Lines: Ideal for transmission towers (33kV to 500kV) due to high tensile strength. Long Spans: Used in river crossings, mountainous areas, and windy regions (resists
Quality 1350 AAC All Aluminum Conductor 95mm 120mm 150mm 185mm 240mm 300mm factory

1350 AAC All Aluminum Conductor 95mm 120mm 150mm 185mm 240mm 300mm

AAC Bare Conductor All Aluminum Conductor 95mm 120mm 150mm 185mm 240mm 300mm Application AAC (All Aluminum Conductor) is a bare overhead cable made of pure aluminum (1350 alloy) without insulation. Overhead Power Transmission & Distribution Utility Lines: Used in low-to-medium voltage overhead distribution (up to 33kV). Rural Electrification: Cost-effective for long-span installations (e.g., poles in remote areas). Service Drops: Connects utility poles to buildings (limited
Quality AAAC All Aluminium Alloy Bare Conductor IEC Standard Good Conductivity factory

AAAC All Aluminium Alloy Bare Conductor IEC Standard Good Conductivity

AAAC All Aluminium Alloy Bare Conductor IEC Standard Product Description AAAC is an overhead bare conductor cable made from high-strength aluminum alloy, widely used in power transmission & distribution networks. Feature Lightweight – Easier installation with longer spans & less sag High Strength-to-Weight Ratio – Better mechanical performance than AAC (All Aluminium Conductor) Excellent Corrosion Resistance – Ideal for coastal/humid environments Good Conductivity – Efficient
Quality Overhead Bare Conductor ACSR Steel Reinforced Aluminum AAC AAAC Conductor factory

Overhead Bare Conductor ACSR Steel Reinforced Aluminum AAC AAAC Conductor

Overhead Bare Conductor ACSR Steel Reinforced Aluminum AAC AAAC Conductor Application Bare conductors are extensively used for overhead distribution and transmission lines adjacent to ocean coastlines where there can be a problem of corrosion in the steel of an ACSR construction. The inductive effect of the ACSR's steel core is eliminated, hence increasing the operating efficiency of the line. Brief Description This conductor is made from aluminium-magnesium silicon alloy of
Quality Thermal Resistant 750 MCM AAAC Aluminum Alloy Conductor for Overhead Power Lines factory

Thermal Resistant 750 MCM AAAC Aluminum Alloy Conductor for Overhead Power Lines

Thermal Resistant 750 MCM AAAC Aluminum Alloy Conductor Overhead Power Lines Application Used for overhead power lines, ground wires, steel stay wires Applicable standards: Aluminum alloy conductor (AAAC) are produced according to ASTM B-399, BS EN-50182, AS/NZS 1531, DIN 48201, CSA 61089, IEC 61089, GB/T 1179, BS 3242, NFC 34-125 or the standards agreed by both of the customers and us. Advantages AAAC products have many advantages for use, like low resistance, large carrying
Quality Custom AAC Aluminum Bare Conductor 16mm2-800mm2 For Overhead Electric Cables factory

Custom AAC Aluminum Bare Conductor 16mm2-800mm2 For Overhead Electric Cables

AAC Aluminum Bare conductor Overhead Electric Cables Applications Stranded 1350 aluminum conductors: Class AA: for bare conductors usually used in overhead lines. Class A: for conductors to be covered with weather-resistant materials and for bare conductors where greater flexibility is required. Construction Aluminum alloy 1350-H19 wires, concentrically stranded Type 1. AAC : All Aluminum Conductor 2.ACSR :Aluminum Conductor Steel Reinforced 3. AAAC :All Alloy Aluminum
Quality High Strength ACSR Aluminum Bare Conductor Steel Wire Core For Overhead Line factory

High Strength ACSR Aluminum Bare Conductor Steel Wire Core For Overhead Line

ACSR Aluminum Bare Conductor Steel Wire Core For Overhead Line Product Description ACSR (Aluminum Conductor Steel Reinforced) is a type of overhead power transmission conductor widely used in electrical grids. It combines the advantages of aluminum and steel, offering high strength, excellent conductivity, and corrosion resistance. Structural Outer Aluminum Layers: Multiple aluminum strands are twisted around the exterior, responsible for conducting electricity. Aluminum
Quality Solid Stranded 70Sq.Mm Bare Copper Conductor For Overhead Power Line factory

Solid Stranded 70Sq.Mm Bare Copper Conductor For Overhead Power Line

70Sq.mm Cu. Bare Copper Conductor for Overhead Power Line Application Solid and stranded bare copper conductors are suitable for overhead transmission and distribution applications. Stranded conductors of greater flexibility are suitable for uninsulated hook up, jumpers and grounds in electrical construction. Construction Bare stranded soft-drawn copper conductor is a concentric-lay-stranded conductor consisting of hard-drawn copper wires available in both single layer and
Quality High Voltage Bare Copper Overhead Conductor Solid Flexible 10~185mm2 factory

High Voltage Bare Copper Overhead Conductor Solid Flexible 10~185mm2

Solid Flexible Copper Bare Conductor Electric Grounding Cable Bare Copper Wire Application This high voltage bare copper conductor is used in overhead power transmission lines. It can also be used as bus line in power stations or other applications where high current carrying capacity is required. Descripction Conductor: stranded hard drawn copper No. of strands: 3, 7, 19, 37 Conductor shape: round Lay direction of outer layer: right Conductor specification Specification
Quality Corrosion Resistant Solid Flexible Bare Copper Conductor Wire For Grounding Cable factory

Corrosion Resistant Solid Flexible Bare Copper Conductor Wire For Grounding Cable

Solid Flexible Copper Bare Conductor Electric Grounding Cable Bare Copper Wire Application Bare Copper is used for the realization of earth sockets in the building but also for the realization of the equipotential bonding in industrial applications. Grounding is mandatory for industrial, domestic installations and the distribution of electricalenergy. Description ‌High Electrical Conductivity ‌: Copper ranks second only to silver in conductivity, ensuring efficient power
Quality Flexible Stranded Copper Bare Conductor Tinned Bare Copper Conductive Round Wire for Underground factory

Flexible Stranded Copper Bare Conductor Tinned Bare Copper Conductive Round Wire for Underground

Flexible Stranded Copper Bare Conductor Cable Tinned Bare Copper Conductive Round Wire for Underground Use Application Power Lines ‌: For cities, towns, and solar/wind farms. ‌Buildings ‌: In homes, offices, and tall buildings ‌Factories/Mines ‌: Powers machines and survives harsh environments. ‌Transportation ‌: For trains, airports, and EV charging stations. ‌Coastal Areas ‌: Good near oceans because saltwater doesn’t damage them. ‌Emergency Use ‌: Quick to set up for
Quality 10-500sq Mm Aluminum Bare Overhead Conductors For Electrical Power Transmission factory

10-500sq Mm Aluminum Bare Overhead Conductors For Electrical Power Transmission

10-500sq mm Aluminum Bare Conductors Aluminum Cable Overhead Application Bare conductors are widely used for electrical power transmission over long distances, since they are ideal for long overhead lines spans. They are also used as a messenger for supporting overhead electrical cables Description Code name Item Application AAC All-aluminium Conductor Mainly for overhead power transmission and primary and secondary distribution AAAC All Aluminimum Alloy Conductor ACSR
Quality Overhead AAAC Bare Conductor Twisted Wire 100mm2 for Power Transmission factory

Overhead AAAC Bare Conductor Twisted Wire 100mm2 for Power Transmission

Overhead AAAC Bare Conductor Cable Twisted Wire 100mm2 for Power Transmission Application The twisted wire is realized by rotating the twisted single wire around the twisted wire axis at equal angular speed and moving the twisted wire forward at uniform speed. It is suitable for the occasions where the working frequency is high and the skin effect and proximity effect loss of single strand wire are too large. The use of stranded wire can reduce the operating temperature,
Quality Lightweight‌ All Aluminum Alloy Conductor AAC AAAC ACSR Conductor For Power Station factory

Lightweight‌ All Aluminum Alloy Conductor AAC AAAC ACSR Conductor For Power Station

All Aluminium Alloy Stranded Bare Conductors AAAC, AAC, ACSR for Power Station AAC - All Aluminum Conductor Application This all aluminum conductor is a kind of aluminum product made through stranding aluminum wires. It is used for the electricity distribution lines with short span length and small load-carrying capability of the pole. The AAC provides reliable performance for overhead power transmission and distribution lines. This standard covers hard drawn circular
Quality OEM Aluminium Alloy Bare Conductor AAAC 25mm2 50mm2 95mm2 120mm2 factory

OEM Aluminium Alloy Bare Conductor AAAC 25mm2 50mm2 95mm2 120mm2

Aluminium Alloy Conductor Bare Conductor AAAC 25mm2 50mm2 95mm2 120mm2 AAC - All Aluminum Conductor Application Overhead Transmission Lines Distribution Networks Renewable Energy Projects Railway Electrification Industrial Power Supply Construction AAC is a concentric-lay-stranded conductor consisting of aluminum alloy 1350-H19 wires available in both single-layer and multi-layer constructions. AAAC - All Aluminum Alloy Conductor Application Used as bare overhead conductor
Quality High Strength Stranded Bare Copper Conductor for 110KV Overhead Line Transmission and Distribution factory

High Strength Stranded Bare Copper Conductor for 110KV Overhead Line Transmission and Distribution

High Strength Bare Copper Conductor for Overhead Line Transmission and Distribution High Strength Bare Copper Conductor is widely used in overhead power lines, substation grounding systems, and railway electrification due to its excellent conductivity and mechanical strength. Construction Bare copper, solid or stranded. Available in tempers hard, medium-hard, or soft. Stranded conductors are concentrically stranded in hard and medium-hard tempers and are Combination Unilay
Quality High Power 132KV ACSR Dog Conductor Bare Conductor Eco Friendly for Overhead Transmission factory

High Power 132KV ACSR Dog Conductor Bare Conductor Eco Friendly for Overhead Transmission

High Power 132KV Bare Conductor ACSR Dog Conductor Eco-friendly overhead transmission line conductor designed for efficient power distribution at 132KV voltage rating. Applications Transmission Networks: Primary use in high-voltage (132KV) overhead transmission lines for long-distance electricity transmission with minimal energy loss Eco-Friendly Design: Composed of recyclable aluminum conductors reinforced with steel, supporting sustainable infrastructure goals Durability &
Quality GSW Bare Conductor Aluminum Alloy Conductor Steel Reinforced for Overhead Distribution IEC61089 factory

GSW Bare Conductor Aluminum Alloy Conductor Steel Reinforced for Overhead Distribution IEC61089

GSW Bare Conductor Aluminum Alloy Conductor Steel Reinforced for Overhead Distribution APPLICATION Steel Wire Galvanized is s uitable for overhead line stay wires, binding and jointing wires. C ONSTRUCTION Core Material ‌ ‌ Zinc Coating CHARA C TERISTIC ‌Corrosion Resistance‌ High Tensile Strength Surface Properties‌ ‌Flexibility‌ ‌Electrical Conductivity SPECIFICATION Stranding & Wire Diameler Overall Diameter Sectional Area Approximate Weight Breaking Load DC Resistance
Quality ACSR Wolf Bare Conductor for Overhead Transmission Lines factory

ACSR Wolf Bare Conductor for Overhead Transmission Lines

ACSR Wolf Bare Conductor for Overhead Transmission Lines APPLICATION ACSR Wolf Bare Conductor‌ is primarily used in ‌overhead power transmission lines‌ for efficient electricity distribution. Its design combines aluminum layers for conductivity and a galvanized steel core for mechanical strength, making it suitable for long-distance transmission across various terrains, including rivers and valleys‌. The conductor operates under high temperatures (up to 95°C) and complies
Prev 1 2 Next