1 Core 3 Core Steel Wire Armoured Cable 6-35kV MV Medium Voltage Power Cable
| Application: | Underground | Armour: | Steel Wire |
| Insulation: | XLPE | Item No: | NYR2Y NAYR2Y |
| Sheath: | PVC | Conductor: | Copper Or Alumium |
| High Light: | Armoured Medium Voltage Power Cable,MV Steel Wire Armoured Cable,1 Core Steel Wire Armoured Cable |
||
Medium Voltage 6-35kV Armoured Electrical Cable 1 Core 3 Core
Application
Medium voltage Armoured power cable for static application in ground, within and outside facilities, outdoor, in cable canals,in water, in conditions where cables are not exposed to heavier mechanical stress and tensile strain..
Construction
- Conductor:Circular, solid, compacted or sector shaped stranded Copper or aluminum
- Insulation:XLPE PE or PVC
- Filler: Non-hygroscopic material
- Inner sheath: PVC
- Armouring: Steel Tape Armoured
- Outer Sheath PVC, XLPE, PVC
Technical data:
- Test Voltage: 3.5kV 5min No Breakdown
- The ambient temperature for installation: ≥0℃.
- Maximum conductor temperature in normal operation:≤90℃.
- Max operating temperature of con. When cable short-circuited(5s maximum duration): 250℃.
- Permissible minimum bending radius:
- Single unarmoured cable: 20 x OD
- Multi-core unarmoured cable: 15 x OD
- Single armoured cable: 5 x OD
- Multi-core armoured cable: 12 x OD
- Note : OD=Overall Diameter of Cable
Product Type
|
General type |
VDE type |
Description |
Application |
|
CU/XLPE/PVC (AL/XLPE/PVC) |
N2XSY N2XSEY (NA2XSY NA2XSEY) |
Cu conductor(Al conductor)XLPE insulated PVC sheathed power cable |
Laying indoors, in tunnel, fixed on the bracket, pipe and buried in the soil, the cable cannot bear external mechanical forces. |
|
CU/XLPE/PE (AL/XLPE/PE) |
N2XS2Y N2XSE2Y (NA2XS2Y NA2XSE2Y) |
Cu conductor(Al conductor)XLPE insulated PE sheathed power cable |
|
|
CU/XLPE/STA/PVC (AL/XLPE/STA/PVC) |
N2XSBY N2XSEBY (NA2XSBY NA2XSEBY) |
Cu conductor(Al conductor)XLPE insulated double of steel-tape armored PVC sheathed power cable |
For laying indoors, in tunnel, cable trench, or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force. |
|
CU/XLPE/STA/PE (AL/XLPE/STA/PE) |
N2XSB2Y N2XSEB2Y (NA2XSB2Y NA2XSEB2Y) |
Cu conductor(Al conductor)XLPE insulated double of steel-tape armored PE sheathed power cable |
|
|
CU/XLPE/ATA/PVC (AL/XLPE/ATA/PVC) |
N2XSBY N2XSEBY (NA2XSBY NA2XSEBY) |
Cu conductor(Al conductor)XLPE insulated double of aluminium-tape armored PVC sheathed power cable |
|
|
CU/XLPE/SWA/PVC (AL/XLPE/SWA/PVC) |
N2XSRY N2XSERY (NA2XSRY NA2XSERY) |
Cu conductor(Al conductor)XLPE insulated steel-wire armored PVC sheathed power cable |
For laying indoors, in tunnel, cable trench, well or direct in ground, able to bear external mechanical forces and certain pulling force |
|
CU/XLPE/SWA/PE (AL/XLPE/SWA/PE) |
N2XSR2Y N2XSER2Y (NA2XSR2Y NA2XSER2Y) |
Cu conductor(Al conductor)XLPE insulated steel-wire armored PE sheathed power cable |
|
|
CU/XLPE/AWA/PVC (AL/XLPE/AWA/PVC) |
N2XSRY N2XSERY (NA2XSRY NA2XSERY) |
Cu conductor(Al conductor)XLPE insulated aluminium-wire armored PE sheathed power cable |
Range of Products
|
No.of cores |
6/6(7.2) 6/10(12.0) |
8.7/10(12) 8.7/15(17.5) |
12/20(24.0) |
18/30(36.0) |
21/35(40.5) |
26/35(40.5) |
|
1 |
25-630 |
25-630 |
25-630 |
25-630 |
50-630 |
50-630 |
|
25-630 |
25-630 |
25-630 |
25-630 |
50-630 |
50-630 |
|
|
25-630 |
25-630 |
25-630 |
25-630 |
50-630 |
50-630 |
|
|
25-630 |
25-630 |
25-630 |
25-630 |
50-630 |
50-630 |
|
|
25-630 |
25-630 |
25-630 |
25-630 |
50-630 |
50-630 |
|
|
25-630 |
25-630 |
25-630 |
25-630 |
50-630 |
50-630 |
|
|
3 |
16-630 |
16-630 |
16-630 |
16-630 |
50-400 |
50-400 |
|
16-630 |
16-630 |
16-630 |
16-630 |
50-400 |
50-400 |
|
|
16-630 |
16-630 |
16-630 |
16-630 |
50-400 |
50-400 |
|
|
16-630 |
16-630 |
16-630 |
16-630 |
50-400 |
50-400 |
|
|
16-630 |
16-630 |
16-630 |
16-630 |
50-400 |
50-400 |
|
|
16-630 |
16-630 |
16-630 |
16-630 |
50-400 |
50-400 |