Cable de energía ABC autoportante ACSRC IEC228 IEC208 IEC502 para línea de distribución aérea

Certificación
China. Zhongdong Cable Co., Ltd. certificaciones
China. Zhongdong Cable Co., Ltd. certificaciones
Estoy en línea para chatear ahora

Cable de energía ABC autoportante ACSRC IEC228 IEC208 IEC502 para línea de distribución aérea

ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228  IEC208  IEC502 For Overhead Distribution Line
ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228  IEC208  IEC502 For Overhead Distribution Line ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228  IEC208  IEC502 For Overhead Distribution Line ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228  IEC208  IEC502 For Overhead Distribution Line ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228  IEC208  IEC502 For Overhead Distribution Line

Ampliación de imagen :  Cable de energía ABC autoportante ACSRC IEC228 IEC208 IEC502 para línea de distribución aérea

Datos del producto:
Lugar de origen: Hebei, China
Nombre de la marca: Zhongdong
Certificación: CCC,ISO,TUV,CE
Número de modelo: abecedario
Pago y Envío Términos:
Cantidad de orden mínima: Negociable
Precio: Negociable
Detalles de empaquetado: Tambor de acero del tambor de madera
Tiempo de entrega: 7-30 días basados en una cantidad diferente
Condiciones de pago: , L/C, T/T
Capacidad de la fuente: 100 km/semana

Cable de energía ABC autoportante ACSRC IEC228 IEC208 IEC502 para línea de distribución aérea

descripción
Aplicación: línea de distribución superior Núcleos nos: 1,2,3,4 más multicore
Voltaje nominal: 15/35kV Título de instalación: -20 ℃ -90 ℃
Mensajeros neutrales: AAC, AAAC o ACSR Aislamiento: PE/PVC
Resaltar:

cable de energía ABC autoportante

,

cable de haz aéreo normas IEC

,

cable de energía para línea de distribución aérea

Cable ABC ACSRC autoportante para líneas aéreas IEC228  IEC208  IEC502 para líneas de distribución aéreas



APLICACIÓN

  • 1 fase:to suministrar servicio aéreo de 120 voltios para servicio temporal en obras de construcción, iluminación exterior o de calles. Para servicio a 1000 voltios o menos a una temperatura del conductor de 75℃ como máximo.
  • 2 fases: to suministrar energía de la compañía de servicios públicoss líneas al consumidors cabezal de intemperie. Para servicio a 1000 voltios o menos (fase a fase) a una temperatura del conductor de 75℃  máximo para aislamiento de polietileno o 90℃  máximo para aislamiento reticulado.
  • 3 fases: generalmente de un transformador montado en poste, al usuarios cabezal de servicio donde se realiza la conexión al cable de entrada de servicio. Para ser utilizado a voltajes de 1000 voltios o menos fase a fase y a temperaturas del conductor que no excedan los 75℃  para conductores aislados con polietileno o 90℃ para conductores aislados con polietileno reticulado (XLPE).


CONSTRUCCIÓN 

Conductor totalmente de aluminio, aislamiento de polietileno o polietileno reticulado, AAC de hilos concéntricos, ACSR o mensajero neutro de aleación 6201.

Cable de energía ABC autoportante ACSRC IEC228 IEC208 IEC502 para línea de distribución aérea 0Cable de energía ABC autoportante ACSRC IEC228 IEC208 IEC502 para línea de distribución aérea 1Cable de energía ABC autoportante ACSRC IEC228 IEC208 IEC502 para línea de distribución aérea 2


MÉTODO DE APLICACIÓN

  • ‌Uso principal‌: Distribución de energía aérea rural y urbana, redes de suministro de energía temporal.
  • Adaptabilidad‌: Funciona de manera confiable en entornos costeros, industriales o de alta humedad debido a los materiales resistentes a la corrosión.

ESPECIFICACIÓN

Descripción

Conductor de fase

Desnudo
Conductor (ACSR)

Aprox. General
Diámetro y peso

NO de Hilos&
Diámetro

XLPE
Grosor

NO de Hilos&
Diámetro

Diámetro
(mm)

Peso
(kg/km)

AL

Acero

1×10mm²+10mm²

7 /1.35

1.0

6/1.35

1/1.35

10.30

858

1×16mm²+16mm²

7/1.70

1.2

6/1.70

1/1.70

12.84

133.7

1×25mm²+25mm²

7/2.22

1.2

62.22

12.22

15.04

215.8

1×35mm²+35mm²

7/2.59

1.4

62.59

12.59

17.8B

294.0

1×50mm²+50mm²

7/3.10

1.4

63.10

13.10

19.68

410.2

1×70mm²+50mm²

19/2.22

1.4

6/3.10

1/3.10

21.38

574.3

1×95mm²+50mm²

19/2.59

1.4

6/3.10

13.10

22.98

704.5

2×10mm²+10mm²

7/1.35

1.0

6/1.35

1/1.35

12.30

120.7

2×16mm²+16mm²

7 /1.70

1.2

6/1.70

1/1.70

15.24

133.7

2×25mm²+25mm²

7/2.22

12

6/2.22

172.22

17.44

310.2

2×35mm²+35mm²

7/ 2.59

1.4

6/2.59

172.59

20.28

422.5

2×50mm²+50mm²

7/3.10

1.4

6/3.10

1/3.10

22.48

594.2

2×70mm²+50mm²

19/2.22

1.4

6/3.10

1/3.10

25.88

964.5

2×95mm²+50mm²

19/2.59

1.4

6/3.10

1/3.10

2908

1224.9

3×10mm²+10mm²

7/1.35

1.0

6/1.35

1/1.35

14.76

187.6

3×16mm²+16mm²

7/1.70

1.2

6/1.70

1/1.70

18.28

290.4

3×25mm²+25mm²

7/2.22

1.2

62.22

12.22

20.92

458.6

3×35mm²+35mm²

7/2.59

1.4

62.59

12.59

24.33

625.0

3×50mm²+50mm²

7/3.10

1.4

63.10

1/3.10

26.97

862.3

3×70mm²+50mm²

19/2.22

1.4

6/3.10

1/3.10

31.05

1354.7

3×95mm²+50mm²

19/2.59

1.4

6/3.10

1/3.10

34.89

1745.3


NUESTRAS PLANTAS


Cable de energía ABC autoportante ACSRC IEC228 IEC208 IEC502 para línea de distribución aérea 3

PROYECTOS

Cable de energía ABC autoportante ACSRC IEC228 IEC208 IEC502 para línea de distribución aérea 4


¿POR QUÉ NOSOTROS?


Cable de energía ABC autoportante ACSRC IEC228 IEC208 IEC502 para línea de distribución aérea 5


PREGUNTAS FRECUENTES

P: ¿Cuál es la forma completa de ACSR en el cable ABC autoportante ACSR?
R: ACSR significa ‌Conductor de aluminio con refuerzo de acero‌, lo que indica un cable con conductores de aluminio y un núcleo de acero para resistencia mecánica

P: ¿Cuál es la clasificación de voltaje máxima para el cable ABC autoportante ACSR?
R: Típicamente clasificado para ‌33 kV a 230 kV‌, dependiendo del aislamiento y los estándares de diseño

P: ¿Cómo mejora el núcleo de acero el rendimiento de los cables ACSR?
R: El núcleo de acero proporciona ‌alta resistencia a la tracción‌, lo que permite tramos más largos entre soportes y resistencia a las cargas de viento/hielo

P: ¿Qué materiales se utilizan en el aislamiento de los cables ABC autoportantes?
R: Los aislantes comunes incluyen ‌polietileno reticulado (XLPE)‌ o ‌PVC‌, con ABC refiriéndose al aislamiento totalmente negro para la resistencia a los rayos UV

P: ¿Se pueden utilizar cables ABC autoportantes ACSR en zonas costeras?
R: Sí, pero ‌se recomiendan núcleos de acero galvanizado‌ y recubrimientos resistentes a la corrosión para entornos de agua salada

P: ¿Cuáles son las aplicaciones típicas de estos cables?
R: Se utilizan en ‌transmisión de energía aérea‌, electrificación rural y redes industriales debido a su durabilidad y rentabilidad

P: ¿Cómo se calcula la comba de los cables ACSR durante la instalación?
R: La comba depende de ‌la longitud del tramo, la tensión y la temperatura‌, con fórmulas proporcionadas en los estándares IEEE o IEC

P: ¿Qué mantenimiento se requiere para los cables ABC autoportantes ACSR?
R: Regular ‌inspecciones visuales‌ para detectar corrosión, daños por aves y contaminación del aislante son esenciales

P: ¿Se pueden enterrar estos cables bajo tierra?
R: Normalmente no están diseñados para enterramiento; utilice ‌cables subterráneos‌ como XLPE para tales aplicaciones