logo
Casa ProdutosCable ABC em conjunto aéreo

Cabo de energia ABC autossustentado ACSRC IEC228 IEC208 IEC502 Para linha de distribuição aérea

Certificado
China Zhongdong Cable Co., Ltd. Certificações
China Zhongdong Cable Co., Ltd. Certificações
Estou Chat Online Agora

Cabo de energia ABC autossustentado ACSRC IEC228 IEC208 IEC502 Para linha de distribuição aérea

ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228  IEC208  IEC502 For Overhead Distribution Line
ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228  IEC208  IEC502 For Overhead Distribution Line ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228  IEC208  IEC502 For Overhead Distribution Line ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228  IEC208  IEC502 For Overhead Distribution Line ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228  IEC208  IEC502 For Overhead Distribution Line

Imagem Grande :  Cabo de energia ABC autossustentado ACSRC IEC228 IEC208 IEC502 Para linha de distribuição aérea

Detalhes do produto:
Lugar de origem: Hebei , China
Marca: Zhongdong
Certificação: CCC,ISO,TUV,CE
Número do modelo: abc
Condições de Pagamento e Envio:
Quantidade de ordem mínima: Negociável
Preço: Negociável
Detalhes da embalagem: Cilindro de aço do cilindro de madeira
Tempo de entrega: 7-30 dias com base em diferentes qty
Termos de pagamento: , L/c, t/t
Habilidade da fonte: 100km/semana

Cabo de energia ABC autossustentado ACSRC IEC228 IEC208 IEC502 Para linha de distribuição aérea

descrição
Aplicação: linha de distribuição aérea Núcleos nos: 1,2,3,4 Mais multicore
Tensão nominal: 15/35kV Grau de instalação: -20 ℃ -90 ℃
Mensageiros neutros: AAC, AAAC ou ACSR Isolamento: PE/PVC
Destacar:

cabo de energia ABC autossustentado

,

cabos agrupados aéreos padrões IEC

,

cabo de energia para linha de distribuição aérea

Cabo de energia ABC auto-sustentado ACSRC IEC228  IEC208  IEC502 para linha de distribuição aérea



APLICAÇÃO

  • 1 fase:to fornecer serviço aéreo de 120 volts para serviço temporário em canteiros de obras, iluminação externa ou pública. Para serviço a 1000 volts ou menos a uma temperatura do condutor de 75℃ no máximo.
  • 2 fases: to fornecer energia da concessionárialinhas para o consumidors cabeçalho de intempéries. Para serviço a 1000 volts ou menos (fase a fase) a uma temperatura do condutor de 75℃  máximo para isolamento de polietileno ou 90℃  máximo para isolamento reticulado.
  • 3 fases: geralmente de um transformador montado em poste, para o usuáriocabeça de serviço onde a conexão com o cabo de entrada de serviço é feita. Para ser usado em tensões de 1000 volts ou menos fase a fase e em temperaturas do condutor que não excedam 75℃  para condutores isolados com polietileno ou 90℃ para condutores isolados com polietileno reticulado (XLPE).


CONSTRUÇÃO 

Todos os condutores de alumínio, isolamento de polietileno ou polietileno reticulado, AAC de fio concêntrico, ACSR ou mensageiro neutro de liga 6201.

Cabo de energia ABC autossustentado ACSRC IEC228 IEC208 IEC502 Para linha de distribuição aérea 0Cabo de energia ABC autossustentado ACSRC IEC228 IEC208 IEC502 Para linha de distribuição aérea 1Cabo de energia ABC autossustentado ACSRC IEC228 IEC208 IEC502 Para linha de distribuição aérea 2


MÉTODO DE APLICAÇÃO

  • ‌Uso principal‌: Distribuição de energia aérea rural e urbana, redes de fornecimento de energia temporárias.
  • Adaptabilidade‌: Funciona de forma confiável em ambientes costeiros, industriais ou de alta umidade devido aos materiais resistentes à corrosão.

ESPECIFICAÇÃO

Descrição

Condutor de fase

Nu
Condutor (ACSR)

Aprox. Geral
Diâmetro e Peso

NÃO de Fios&
Diâmetro

XLPE
Espessura

NÃO de Fios&
Diâmetro

Diâmetro
(mm)

Peso
(kg/km)

AL

Aço

1×10mm²+10mm²

7 /1.35

1.0

6/1.35

1/1.35

10.30

858

1×16mm²+16mm²

7/1.70

1.2

6/1.70

1/1.70

12.84

133.7

1×25mm²+25mm²

7/2.22

1.2

62.22

12.22

15.04

215.8

1×35mm²+35mm²

7/2.59

1.4

62.59

12.59

17.8B

294.0

1×50mm²+50mm²

7/3.10

1.4

63.10

13.10

19.68

410.2

1×70mm²+50mm²

19/2.22

1.4

6/3.10

1/3.10

21.38

574.3

1×95mm²+50mm²

19/2.59

1.4

6/3.10

13.10

22.98

704.5

2×10mm²+10mm²

7/1.35

1.0

6/1.35

1/1.35

12.30

120.7

2×16mm²+16mm²

7/1.70

1.2

6/1.70

1/1.70

15.24

133.7

2×25mm²+25mm²

7/2.22

12

6/2.22

172.22

17.44

310.2

2×35mm²+35mm²

7/ 2.59

1.4

6/2.59

172.59

20.28

422.5

2×50mm²+50mm²

7/3.10

1.4

6/3.10

1/3.10

22.48

594.2

2×70mm²+50mm²

19/2.22

1.4

6/3.10

1/3.10

25.88

964.5

2×95mm²+50mm²

19/2.59

1.4

6/3.10

1/3.10

2908

1224.9

3×10mm²+10mm²

7/1.35

1.0

6/1.35

1/1.35

14.76

187.6

3×16mm²+16mm²

7/1.70

1.2

6/1.70

1/1.70

18.28

290.4

3×25mm²+25mm²

7/2.22

1.2

62.22

12.22

20.92

458.6

3×35mm²+35mm²

7/2.59

1.4

62.59

12.59

24.33

625.0

3×50mm²+50mm²

7/3.10

1.4

63.10

1/3.10

26.97

862.3

3×70mm²+50mm²

19/2.22

1.4

6/3.10

1/3.10

31.05

1354.7

3×95mm²+50mm²

19/2.59

1.4

6/3.10

1/3.10

34.89

1745.3


NOSSAS PLANTAS


Cabo de energia ABC autossustentado ACSRC IEC228 IEC208 IEC502 Para linha de distribuição aérea 3

PROJETOS

Cabo de energia ABC autossustentado ACSRC IEC228 IEC208 IEC502 Para linha de distribuição aérea 4


POR QUE NÓS?


Cabo de energia ABC autossustentado ACSRC IEC228 IEC208 IEC502 Para linha de distribuição aérea 5


PERGUNTAS FREQUENTES

P: Qual é a forma completa de ACSR no Cabo ABC auto-sustentado ACSR?
A: ACSR significa ‌Condutor de Alumínio Reforçado com Aço‌, indicando um cabo com condutores de alumínio e um núcleo de aço para resistência mecânica

P: Qual é a classificação de tensão máxima para o Cabo ABC auto-sustentado ACSR?
A: Normalmente classificado para ‌33 kV a 230 kV‌, dependendo dos padrões de isolamento e design

P: Como o núcleo de aço melhora o desempenho dos cabos ACSR?
A: O núcleo de aço fornece ‌alta resistência à tração‌, permitindo vãos mais longos entre os suportes e resistência a cargas de vento/gelo

P: Quais materiais são usados no isolamento dos Cabos ABC auto-sustentados?
A: Os isoladores comuns incluem ‌polietileno reticulado (XLPE)‌ ou ‌PVC‌, com ABC referindo-se ao isolamento All-Black para resistência aos raios UV

P: Os Cabos ABC auto-sustentados ACSR podem ser usados em áreas costeiras?
A: Sim, mas ‌núcleos de aço galvanizado‌ e revestimentos resistentes à corrosão são recomendados para ambientes de água salgada

P: Quais são as aplicações típicas desses cabos?
A: Usado em ‌transmissão de energia aérea‌, eletrificação rural e redes industriais devido à sua durabilidade e custo-efetividade

P: Como você calcula a flecha dos cabos ACSR durante a instalação?
A: A flecha depende de ‌comprimento do vão, tensão e temperatura‌, com fórmulas fornecidas nas normas IEEE ou IEC

P: Que manutenção é necessária para os Cabos ABC auto-sustentados ACSR?
A: Regular ‌inspeções visuais‌ para corrosão, danos de pássaros e contaminação do isolador são essenciais

P: Esses cabos podem ser enterrados no subsolo?
A: Normalmente não projetados para enterramento; use ‌cabos subterrâneos‌ como XLPE para tais aplicações









Contacto
Zhongdong Cable Co., Ltd.

Pessoa de Contato: Mr. Bai

Telefone: +8619829885532

Envie sua pergunta diretamente para nós (0 / 3000)