logo

XLPE isolou o cabo distribuidor de corrente

Qualidade 3 Core XLPE Insulated Power Cable 0.6/1kV IEC 60502 90°C Rated for Industrial Underground Distribution Fábrica

3 Core XLPE Insulated Power Cable 0.6/1kV IEC 60502 90°C Rated for Industrial Underground Distribution

Fabricado de acordo com IEC 60502, este cabo de alimentação isolado em XLPE de 3 núcleos com construção CU/XLPE/PVC oferece distribuição confiável de 0,6/1kV a 90°C contínuo. Ideal para redes de energia industriais, instalação de dutos subterrâneos e sistemas de distribuição predial.
Qualidade Fire-Resistant XLPE Insulated Single Core Power Cable 0.6/1kV IEC 60331 for Emergency Safety Circuits Fábrica

Fire-Resistant XLPE Insulated Single Core Power Cable 0.6/1kV IEC 60331 for Emergency Safety Circuits

Projetado de acordo com a norma IEC 60331, este cabo de alimentação XLPE de núcleo único resistente ao fogo apresenta tecnologia de barreira de fita de mica para sistemas de emergência que exigem integridade do circuito durante incêndio. Ideal para bombas de incêndio, iluminação de evacuação e circuitos de segurança em hospitais, túneis e edifícios altos.
Qualidade 240mm2 Single Core XLPE Cabos de Energia Isolados 0.6/1kV IEC 60502-1 Fábrica

240mm2 Single Core XLPE Cabos de Energia Isolados 0.6/1kV IEC 60502-1

240mm² Single Core XLPE Insulated Power Cable | 0.6/1kV | IEC 60502-1 Product Overview The 240mm² Single Core XLPE Insulated Power Cable is a low-voltage (0.6/1kV) energy cable designed for fixed installation in power distribution networks, industrial facilities, commercial buildings, and infrastructure projects. Fully compliant with IEC 60502-1, this cable delivers superior electrical performance, thermal stability, and mechanical durability. Key Applications: Power supply
Qualidade 8.7/15kV XLPE Cabos de energia de cobre isolados com PVC SWA CWS para instalação subterrânea Fábrica

8.7/15kV XLPE Cabos de energia de cobre isolados com PVC SWA CWS para instalação subterrânea

8.7/15kV XLPE Insulated Copper Power Cable with CWS SWA PVC for Underground Installation Product Overview The 8.7/15kV copper conductor power cable is designed for medium voltage power distribution systems. It adopts XLPE insulation combined with copper wire screen (CWS), steel wire armour (SWA), and a PVC outer sheath to provide stable electrical performance and mechanical protection. This cable structure is suitable for fixed installations where reliability and durability
Qualidade Cable de alimentação de alumínio XLPE com cobertura de PVC de tela de cobre NA2XSY NA2XSEY Fábrica

Cable de alimentação de alumínio XLPE com cobertura de PVC de tela de cobre NA2XSY NA2XSEY

Aluminium Conductor XLPE Power Cable with Copper Screen PVC Sheath NA2XSY NA2XSEY Application NA2XSY NA2XSEY aluminium conductor XLPE cables are mainly used for medium voltage power transmission and distribution, especially outdoor, underground, or industrial environments where electrical safety, screening, and long service life are critical. Construction Conductor: Aluminium (good conductivity, lighter than copper) Insulation: XLPE (cross-linked polyethylene) — high
Qualidade 8.7/ 15kV XLPE Cabos de alimentação isolados Norma IEC60502-2 para sistemas de transmissão de energia Fábrica

8.7/ 15kV XLPE Cabos de alimentação isolados Norma IEC60502-2 para sistemas de transmissão de energia

8.7/ 15kV XLPE Insulated Power Cable IEC60502-2 Standard for Power Transmission System Application of 8.7/15kV XLPE Insulated Power Cable 8.7/15 kV XLPE insulated power cable manufactured in accordance with IEC 60502-2 is designed for medium-voltage power transmission and distribution systems. It is widely used to transmit electrical power from substations to industrial facilities, commercial buildings, and local distribution networks. Construction Conductor: Class 2 stranded
Qualidade Condutor de Alumínio XLPE SWA LSZH IEC 60502-1 0.6/1kV Cabo NA2XRH Fábrica

Condutor de Alumínio XLPE SWA LSZH IEC 60502-1 0.6/1kV Cabo NA2XRH

Aluminium Conductor XLPE SWA LSZH IEC 60502-1 0.6/1kV Cable NA2XRH APPLICATION For installation on or under the plaster Fixed installation indoor, in air or concrete. For buildings or industrial plants with a high density of people or valuable assets. No direct burial or installation in water. Outdoor laying only when protected from direct sunlight and other external impacts CONSUCTRUCTION Conductor: Class 2 stranded aluminium conductorInsulation: XLPE (Cross-Linked
Qualidade USE- 2 cabos de energia eléctrica Fábrica

USE- 2 cabos de energia eléctrica

Philippine Standards Medium Voltage XLPE Insulated Power Cable for Industrial Use USE-2 Cable APPLICATION Suitable for power supply lines with flame retardant requirements, such as urban underground power grids, power station outgoing lines, and internal power lines of industrial and mining enterprises. CONSUCTRUCTION Conductor:Class 2 stranded plain copper conductor Conductor screen:Semi-conducting material Insulation:XLPE Insulation Screen:Semi-conducting material Metallic
Qualidade Tailândia XLPE Cabo de alimentação isolado CU/xlpe/ PVC blindado de núcleo único 500 mm Fábrica

Tailândia XLPE Cabo de alimentação isolado CU/xlpe/ PVC blindado de núcleo único 500 mm

Thailand XLPE Insulated Power Cable Cu/xlpe/ PVC Armoured Single Core 500mm APPLICATION Power cables for power networks, underground, outdoors and in cable ducting. CONSUCTRUCTION Conductor:Class 2 stranded plain copper conductor to BS EN 60228:2005 Conductor screen:Semi-conducting material Insulation:XLPE (Cross-Linked Polyethylene) Type GP8 to BS7655 Insulation Screen:Semi-conducting material Metallic Screen:Individual and overall copper tape screen to BS6622 Filler:PETP
Qualidade 26/35kV Xlpe Isolado Swa Blindado Médio Voltagem Pura 3x240mm2 Cabo de Energia Subterrânea de cobre Fábrica

26/35kV Xlpe Isolado Swa Blindado Médio Voltagem Pura 3x240mm2 Cabo de Energia Subterrânea de cobre

26/35kV Xlpe Insulated Swa Armoured Medium Voltage Pure 3x240mm2 Copper Underground Power Cable APPLICATION Suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in wateras well as for installation on cable trays for industries, switchboards and power stations. CONSUCTRUCTION Conductor material: Copper Conductor flexibility: Stranded class 5 Insulation: XLPE(Cross-linked Polyethylene Inner sheath: PVC Armour type:
Qualidade IEC 60502-2 XLPE Cabos de alimentação de alumínio blindado 3X300mm 3X150mm com retardador de chama Fábrica

IEC 60502-2 XLPE Cabos de alimentação de alumínio blindado 3X300mm 3X150mm com retardador de chama

IEC 60502-2 XLPE Insulated Aluminium Armoured 3X300mm 3X150mm Flame Retardant Power Cable Applications The cables arewidely used in places such as wind farms and solar power stations to meet the power transmission needs of these places ‌ Main Technical Properties 1. DC resistance of conductor at 20°C : not exceed ing 0.1 Ω/km; 2. 4h Power Frequency Voltage Test (4U₀) : No breakdown occurred; 3. 50Hz AC Withstand Voltage Test: 65 kV for 30 min ; No breakdown occurred; 4.
Qualidade Cabo Elétrico Isolado XLPE 3.6-35kV MV NA2XSY NA2XSY para Transmissão Elétrica Fábrica

Cabo Elétrico Isolado XLPE 3.6-35kV MV NA2XSY NA2XSY para Transmissão Elétrica

MV 3.6-35kV XLPE Insulated Electrical Wire NA2XSY NA2XSY for Electrical Transmission NA2XSY NA2XSY for Electrical Transmission Application The NA2XSY XLPE insulated electrical wire is a medium-voltage power cable designed for reliable power transmission and distribution in various demanding environments.Suitable for power transmission and distribution lines with a rated power frequency voltage of ‌3.6/6kV to 26/35kV‌.Typical Applications‌:Industrial Power Distribution‌: Used
Qualidade Cabos de alimentação isolados XLPE resistentes ao fogo CU/XLPE/STA/PE para aplicações de segurança contra incêndio Fábrica

Cabos de alimentação isolados XLPE resistentes ao fogo CU/XLPE/STA/PE para aplicações de segurança contra incêndio

Fire Resistant XLPE Insulated Power Cable CU/XLPE/STA/PE for Fire Safety Applications This fire-resistant cable is designed for low-voltage power distribution systems where fire safety is critical, rated for 0.6/1kV applications. Applications This specialized power cable is designed for critical fire safety applications where reliable performance under extreme conditions is paramount. Its core application lies in ‌emergency power supply systems‌. Construction Details
Qualidade 35kV XLPE Insulated Steel Wire Armoured Cable CU/XLPE/CTS/STA/PVC Flame-retardant Power Cable Fábrica

35kV XLPE Insulated Steel Wire Armoured Cable CU/XLPE/CTS/STA/PVC Flame-retardant Power Cable

35kV XLPE Insulated Steel Wire Armoured Cable CU/XLPE/CTS/STA/PVC Flame-retardant Power Cable APPLICATION Power Transmission & Distribution‌: Widely used in urban grids, industrial plants, and substations for medium-voltage power transmission (up to 35kV)‌ Harsh Environments‌: Suitable for underground laying, cable trenches, or areas requiring mechanical protection due to its steel wire armour (STA)‌ Flame-Retardant Requirements‌: Deployed in high-risk zones (e.g., mines,
Qualidade EAC Certificado XLPE Isolado 8,7kV 15kV 25mm2-800mm2 Cabo de alimentação retardador de chama Fábrica

EAC Certificado XLPE Isolado 8,7kV 15kV 25mm2-800mm2 Cabo de alimentação retardador de chama

EAC Certificated XLPE Insulated 8.7kV 15kV 25mm2-800mm2 Flame-retardant Power Cable APPLICATION Suitable for power supply lines with flame retardant requirements, such as urban underground power grids, power station outgoing lines, and internal power lines of industrial and mining enterprises. CONSTRUCTION C onductor: Tightly press circular conductor Conductor shield: S emi conductive shielding material (below 500mm ² ) Semi conductive tape+semi conductive shielding material
Qualidade MV Medium Voltage XLPE Insulated Power Cable Three Core Copper Tape Shield EN60502 Fábrica

MV Medium Voltage XLPE Insulated Power Cable Three Core Copper Tape Shield EN60502

MV Medium Voltage XLPE Insulated Power Cable Three Core Copper Tape Shield EN60502 APPLICATION ‌Urban & Industrial Power Networks‌:Used in ‌substations, factories, and commercial buildings‌ for reliable power transmission. Suitable for ‌underground cabling‌ in densely populated areas due to its ‌copper tape shielding‌, which reduces electromagnetic interference (EMI)‌ ‌Renewable Energy Projects‌:Deployed in ‌wind farms and solar power plants‌ for medium-voltage connections
Qualidade Cabo de energia isolado com XLPE Multi Core, Condutor de Cobre, Cabo à prova de fogo com isolamento XLPE EN 60332 Fábrica

Cabo de energia isolado com XLPE Multi Core, Condutor de Cobre, Cabo à prova de fogo com isolamento XLPE EN 60332

Multi Core XLPE Insulated Power Cable Cu Conductor Fire Proof Cable with XLPE Insulation EN 60332 APPLICATION ‌Industrial Facilities ‌ Widely used in petrochemical plants, steel mills, and power stations due to its high-temperature resistance (up to 90°C continuous operation) and flame-retardant properties (compliance with IEC 60332-3-22 for group flame spread limits)‌ High-Rise Buildings & Underground Installations ‌ Essential for fire safety in vertical shafts, cable
Qualidade 3 núcleos XLPE Condutor de alumínio isolado STA Cabo de alimentação blindado NA2XBY Fábrica

3 núcleos XLPE Condutor de alumínio isolado STA Cabo de alimentação blindado NA2XBY

3 Core XLPE Insulated Aluminium Conductor STA Armoured Power Cable NA2XBY APPLICATION Primarily used in power supply stations, industrial facilities, and switchboards Suitable for indoor installation in cable ducts and outdoor environments Can be installed underground and in water applications Commonly employed in power distribution systems for industries Used in cable tray installations for various industrial applications CONSTRUCTION ‌Conductor: Class 2 stranded aluminum
Qualidade Condutor de liga de alumínio XLPE Cabo de alimentação isolado 3 núcleos NA2XS2Y / NA2XS(F) 2Y / NA2X(FL) 2Y Fábrica

Condutor de liga de alumínio XLPE Cabo de alimentação isolado 3 núcleos NA2XS2Y / NA2XS(F) 2Y / NA2X(FL) 2Y

Aluminium Alloy Conductor XLPE Insulated Power Cable 3 Core NA2XS2Y / NA2XS(F)2Y / NA2X(FL)2Y APPLICATION ‌Industrial & Commercial Power Supply ‌: Widely used in factory power distribution, substations, and large-scale commercial buildings. Direct Burial ‌: The steel tape armor (ST) provides excellent mechanical protection against impacts and crushing forces, making it suitable for direct burial in rocky or hard soil. Bridge & Tunnel Applications ‌: Preferred in bridges and
Qualidade Cabo de energia isolado com XLPE resistente ao fogo 1,5-800mm2 1-5 Condutores CU/XLPE/PVC Fábrica

Cabo de energia isolado com XLPE resistente ao fogo 1,5-800mm2 1-5 Condutores CU/XLPE/PVC

Fire Resistant XLPE Insulated Power Cable 1.5-800mm2 1-5 Core CU/XLPE/PVC APPLICATION The cable is a ‌fire-resistant , ‌XLPE-insulated , and ‌PVC-sheathed power cable rated for voltages up to ‌0.6/1 kV ‌. It is widely used in: ‌Power Distribution Systems ‌ – Suitable for fixed installations in buildings, industrial plants, and infrastructure projects, delivering reliable power transmission in low-voltage networks. Fire Safety Critical Areas ‌ – The ‌"N" (fire-resistant) ‌
Qualidade Cabos de alimentação de média tensão isolados XLPE com condutor de liga de alumínio Fábrica

Cabos de alimentação de média tensão isolados XLPE com condutor de liga de alumínio

Aluminium Alloy Conductor XLPE Insulated Power Cable Copper Wire Shield XLPE/PVC/STA Medium Voltage Application Used for tall building, Hospital, Theatre, Power station, Metro Tunnel or Petrochemical Industry or other special place required for low smoke , zero halogen clean and safe cable. Construction Conductor Conductor Shield Insulation Metal Shield Layer Filler Binder Tape Armouring Outer sheath Laying Method Pipe laying, trench laying, tunnel laying, vertical shaft and
Qualidade 35kV MV XLPE cabo elétrico Copper Wire Shield 3 Core comprimento personalizado Fábrica

35kV MV XLPE cabo elétrico Copper Wire Shield 3 Core comprimento personalizado

35kV MV XLPE Insulated Power Cable Copper Wire Shield XLPE/PVC/STA AA-8000 Series Application Used for tall building, Hospital, Theatre, Power station, Metro Tunnel or Petrochemical Industry or other special place required for low smoke , zero halogen clean and safe cable. Construction 1. Conductor Round compacted conductors 2. Conductor Shield Semi conductive shielding material (below 500mm 2 Semi conductive tape+semi conductive shielding material (500 mm2 and above) 3.
Qualidade N2X2y XLPE cabo de energia, LV XLPE cabo isolado UV resistente Fábrica

N2X2y XLPE cabo de energia, LV XLPE cabo isolado UV resistente

N2X2y XLPE Insulated Power Cable 0.6/1 Kv Cu/XLPE/HDPE Application Power distribution cables in power stations, industrial installations and switchgears, as well as in local mains. For fi xed installation underground, in interior premises, cable ducts, in the open air and in water – as permitted by the local building regulations – under severe mechanical stress during installation and operation. Construction Copper conductor, round stranded (RM), resp. sector-shaped stranded
Qualidade Cable de alimentação industrial padrão IEC XLPE isolado Cu condutor PVC revestido Fábrica

Cable de alimentação industrial padrão IEC XLPE isolado Cu condutor PVC revestido

IEC Standard Industrial Power Cable XLPE Insulated Cu-conductor PVC Sheathed Application XLPE (cross-linked polyethylene) insulated power cables are widely used in electrical distribution and transmission systems due to their excellent performance characteristics. Here’s an overview of their features, benefits, and applications. Construction Conductor: Plain Annealed copper conductor or Al-Alloy Mica tape:Each individual conductor is wrapped mica tape which can withstand the
Anterior 1 2 A seguir.