ACSRC Cable d'alimentation ABC aérien auto-portant IEC228 IEC208 IEC502 Pour la ligne de distribution aérienne

ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228  IEC208  IEC502 For Overhead Distribution Line
ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228  IEC208  IEC502 For Overhead Distribution Line ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228  IEC208  IEC502 For Overhead Distribution Line ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228  IEC208  IEC502 For Overhead Distribution Line ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228  IEC208  IEC502 For Overhead Distribution Line

Image Grand :  ACSRC Cable d'alimentation ABC aérien auto-portant IEC228 IEC208 IEC502 Pour la ligne de distribution aérienne

Détails sur le produit:
Lieu d'origine: Hebei , Chine
Nom de marque: Zhongdong
Certification: CCC,ISO,TUV,CE
Numéro de modèle: abc
Conditions de paiement et expédition:
Quantité de commande min: Négociable
Prix: Négociable
Détails d'emballage: Tambour métallique en bois de tambour
Délai de livraison: 7-30 jours basés sur différentes Qté
Conditions de paiement: , L / c, t / t
Capacité d'approvisionnement: 100 km / semaine

ACSRC Cable d'alimentation ABC aérien auto-portant IEC228 IEC208 IEC502 Pour la ligne de distribution aérienne

description de
Application: ligne de distribution aérienne Cœurs n °: 1,2,3,4 plus multiccore
Tension nominale: 15/35KV Diplôme d'installation: -20 ℃ -90 ℃
Messagers neutres: AAC, AAAC ou ACSR Isolation: PE / PVC
Mettre en évidence:

câble d'alimentation ABC autoportant

,

normes CEI pour les câbles aériens groupés

,

câble d'alimentation de ligne de distribution aérienne

Câble ABC aérien autosupporté ACSRC IEC228  IEC208  IEC502 pour ligne de distribution aérienne



APPLICATION

  • 1 phase : to alimenter en 120 volts aériens pour un service temporaire sur les chantiers de construction, l'éclairage extérieur ou public. Pour un service à 1000 volts ou moins à une température de conducteur de 75℃ maximum.
  • 2 phases : to alimenter en énergie à partir des lignes de l'entreprise de services publicss vers le consommateurs tête de raccordement. Pour un service à 1000 volts ou moins (phase à phase) à une température de conducteur de 75℃  maximum pour une isolation en polyéthylène ou 90℃  maximum pour une isolation réticulée.
  • 3 phases: généralement à partir d'un transformateur monté sur poteau, vers la tête de service de l'utilisateuroù le raccordement au câble d'entrée de service est effectué. À utiliser à des tensions de 1000 volts ou moins phase à phase et à des températures de conducteur ne dépassant pas 75℃  pour les conducteurs isolés en polyéthylène ou 90℃ pour les conducteurs isolés en polyéthylène réticulé (XLPE).


CONSTRUCTION 

Conducteur entièrement en aluminium, isolation en polyéthylène ou en polyéthylène réticulé, toron concentrique AAC, ACSR ou neutre en alliage 6201.

ACSRC Cable d'alimentation ABC aérien auto-portant IEC228 IEC208 IEC502 Pour la ligne de distribution aérienne 0ACSRC Cable d'alimentation ABC aérien auto-portant IEC228 IEC208 IEC502 Pour la ligne de distribution aérienne 1ACSRC Cable d'alimentation ABC aérien auto-portant IEC228 IEC208 IEC502 Pour la ligne de distribution aérienne 2


MÉTHODE D'APPLICATION

  • ‌Utilisation principale‌: Distribution d'énergie aérienne rurale et urbaine, réseaux d'alimentation temporaires.
  • Adaptabilité‌: Fonctionne de manière fiable dans les environnements côtiers, industriels ou à forte humidité grâce à des matériaux résistants à la corrosion.

SPÉCIFICATION

Description

Conducteur de phase

Nu
Conducteur (ACSR)

Diamètre et poids approximatifs

de  Torons&Diamètre
(mm)

Épaisseur

de  Torons&Diamètre
(mm)

(mm)
Poids

(kg/km)
AL

Acier

1×10mm²+10mm²

7 /1.35

1.0

6/1.35

1/1.35

14.76

858

1×16mm²+16mm²

7/1.70

1.2

62.22

1/1.70

18.28

133.7

2×25mm²+25mm²

7/2.22

1.2

62.22

12.22

20.92

215.8

1×35mm²+35mm²

7/2.59

1.4

6/3.10

12.59

24.33

294.0

1×50mm²+50mm²

7/3.10

1.4

6/3.10

1/3.10

22.98

410.2

1×70mm²+50mm²

19/2.22

1.4

6/3.10

1/3.10

34.89

574.3

1×95mm²+50mm²

19/2.59

1.4

6/3.10

1/3.10

22.98

704.5

2×10mm²+10mm²

7/1.35

1.0

6/1.35

1/1.35

14.76

120.7

2×16mm²+16mm²

7/1.70

1.2

62.22

1/1.70

18.28

133.7

2×25mm²+25mm²

7/2.22

1.2

6/2.22

172.22

17.44

310.2

2×35mm²+35mm²

7/ 2.59

1.4

6/3.10

172.59

20.28

422.5

2×50mm²+50mm²

7/3.10

1.4

6/3.10

1/3.10

34.89

594.2

2×70mm²+50mm²

19/2.22

1.4

6/3.10

1/3.10

34.89

964.5

2×95mm²+50mm²

19/2.59

1.4

6/3.10

1/3.10

34.89

1224.9

3×10mm²+10mm²

7/1.35

1.0

6/1.35

1/1.35

14.76

187.6

3×16mm²+16mm²

7/1.70

1.2

62.22

1/1.70

18.28

290.4

3×25mm²+25mm²

7/2.22

1.2

62.22

12.22

20.92

458.6

3×35mm²+35mm²

7/2.59

1.4

6/3.10

12.59

24.33

625.0

3×50mm²+50mm²

7/3.10

1.4

6/3.10

1/3.10

34.89

862.3

3×70mm²+50mm²

19/2.22

1.4

6/3.10

1/3.10

34.89

1354.7

3×95mm²+50mm²

19/2.59

1.4

6/3.10

1/3.10

34.89

1745.3

NOS PLANTES


PROJETS


ACSRC Cable d'alimentation ABC aérien auto-portant IEC228 IEC208 IEC502 Pour la ligne de distribution aérienne 3

POURQUOI NOUS ?

ACSRC Cable d'alimentation ABC aérien auto-portant IEC228 IEC208 IEC502 Pour la ligne de distribution aérienne 4


FAQ


ACSRC Cable d'alimentation ABC aérien auto-portant IEC228 IEC208 IEC502 Pour la ligne de distribution aérienne 5


R : Généralement pas conçus pour l'enfouissement ; utilisez ‌R : Généralement pas conçus pour l'enfouissement ; utilisez ‌
Conducteur en aluminium renforcé d'acier‌, indiquant un câble avec des conducteurs en aluminium et une âme en acier pour la résistance mécanique

R : Généralement pas conçus pour l'enfouissement ; utilisez ‌R : Généralement pas conçus pour l'enfouissement ; utilisez ‌
33 kV à 230 kV‌, selon les normes d'isolation et de conception

R : Généralement pas conçus pour l'enfouissement ; utilisez ‌R : Généralement pas conçus pour l'enfouissement ; utilisez ‌
une résistance à la traction élevée‌, permettant des portées plus longues entre les supports et une résistance aux charges de vent/glace

R : Généralement pas conçus pour l'enfouissement ; utilisez ‌R : Généralement pas conçus pour l'enfouissement ; utilisez ‌
le polyéthylène réticulé (XLPE)‌ ou ‌PVC‌, avec ABC faisant référence à une isolation entièrement noire pour la résistance aux UV

R : Généralement pas conçus pour l'enfouissement ; utilisez ‌R : Généralement pas conçus pour l'enfouissement ; utilisez ‌
les âmes en acier galvanisé‌ et les revêtements résistants à la corrosion sont recommandés pour les environnements salins

R : Généralement pas conçus pour l'enfouissement ; utilisez ‌R : Généralement pas conçus pour l'enfouissement ; utilisez ‌
la transmission d'énergie aérienne‌, l'électrification rurale et les réseaux industriels en raison de leur durabilité et de leur rentabilité

R : Généralement pas conçus pour l'enfouissement ; utilisez ‌R : Généralement pas conçus pour l'enfouissement ; utilisez ‌
la longueur de la portée, de la tension et de la température‌, avec des formules fournies dans les normes IEEE ou CEI

R : Généralement pas conçus pour l'enfouissement ; utilisez ‌R : Généralement pas conçus pour l'enfouissement ; utilisez ‌
inspections visuelles régulières‌ pour la corrosion, les dommages causés par les oiseaux et la contamination des isolateurs sont essentielles

R : Généralement pas conçus pour l'enfouissement ; utilisez ‌R : Généralement pas conçus pour l'enfouissement ; utilisez ‌
des câbles souterrains‌ comme le XLPE pour de telles applications