logo
Rumah ProdukKabel terbungkus udara ABC

ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228 IEC208 IEC502 Untuk Jalur Distribusi Udara

Sertifikasi
Cina Zhongdong Cable Co., Ltd. Sertifikasi
Cina Zhongdong Cable Co., Ltd. Sertifikasi
I 'm Online Chat Now

ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228 IEC208 IEC502 Untuk Jalur Distribusi Udara

ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228  IEC208  IEC502 For Overhead Distribution Line
ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228  IEC208  IEC502 For Overhead Distribution Line ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228  IEC208  IEC502 For Overhead Distribution Line ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228  IEC208  IEC502 For Overhead Distribution Line ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228  IEC208  IEC502 For Overhead Distribution Line

Gambar besar :  ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228 IEC208 IEC502 Untuk Jalur Distribusi Udara

Detail produk:
Tempat asal: Hebei, Cina
Nama merek: Zhongdong
Sertifikasi: CCC,ISO,TUV,CE
Nomor model: ABC
Syarat-syarat pembayaran & pengiriman:
Kuantitas min Order: Bisa dinegosiasikan
Harga: dapat dinegosiasikan
Kemasan rincian: Drum Kayu / Drum Baja
Waktu pengiriman: 7-30 hari berdasarkan qty yang berbeda
Syarat-syarat pembayaran: , L/c, t/t
Menyediakan kemampuan: 100 km/minggu

ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228 IEC208 IEC502 Untuk Jalur Distribusi Udara

Deskripsi
Aplikasi: Jalur distribusi overhead Core No.: 1,2,3,4 lebih multicore
Tegangan Dinilai: 15/35KV Gelar Instalasi: -20 ℃ -90 ℃
Utusan netral: AAC, AAAC atau ACSR Isolasi: PE/PVC
Menyoroti:

kabel listrik ABC yang mendukung diri

,

standar IEC kabel udara yang dikemas

,

Kabel listrik saluran distribusi udara

Kabel Daya ABC Self-Supporting ACSRC IEC228  IEC208  IEC502 Untuk Saluran Distribusi Udara



APLIKASI

  • 1 fase:to memasok layanan udara 120 volt untuk layanan sementara di lokasi konstruksi, penerangan luar ruangan atau jalan. Untuk layanan pada 1000 volt atau lebih rendah pada suhu konduktor maksimum 75℃.
  • 2 fase: to memasok daya dari utilitass saluran ke konsumens weatherhead. Untuk layanan pada 1000 volt atau kurang (fase ke fase) pada suhu konduktor 75℃  maksimum untuk Isolasi polietilena atau 90℃  maksimum untuk isolasi silang.
  • 3 fase: biasanya dari transformator yang dipasang di tiang, ke penggunas service head tempat koneksi ke kabel masuk layanan dibuat. Untuk digunakan pada tegangan 1000 volt atau kurang fase ke fase dan pada suhu konduktor tidak melebihi 75℃  untuk konduktor berinsulasi polietilena atau 90℃ untuk konduktor berinsulasi polietilena (XLPE) yang dihubungkan silang.


KONSTRUKSI 

Semua konduktor aluminium, isolasi polietilena atau polietilena yang dihubungkan silang, AAC untai konsentris, ACSR, atau pengantar netral paduan 6201.

ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228 IEC208 IEC502 Untuk Jalur Distribusi Udara 0ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228 IEC208 IEC502 Untuk Jalur Distribusi Udara 1ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228 IEC208 IEC502 Untuk Jalur Distribusi Udara 2


METODE APLIKASI

  • Penggunaan Utama‌: Distribusi daya udara pedesaan dan perkotaan, jaringan pasokan daya sementara.
  • Adaptasi‌: Bekerja andal di lingkungan pesisir, industri, atau kelembaban tinggi karena bahan tahan korosi.

SPESIFIKASI

Deskripsi

Konduktor fase

Telanjang
Konduktor (ACSR)

Perkiraan Keseluruhan
Diameter&Berat

TIDAK dari Berdiri&
Diameter

XLPE
Ketebalan

TIDAK dari Untaian&
Diameter

Diameter
(mm)

Berat
(kg/km)

AL

Baja

1×10mm²+10mm²

7 /1.35

1.0

6/1.35

1/1.35

10.30

858

1×16mm²+16mm²

7/1.70

1.2

6/1.70

1/1.70

12.84

133.7

1×25mm²+25mm²

7/2.22

1.2

62.22

12.22

15.04

215.8

1×35mm²+35mm²

7/2.59

1.4

62.59

12.59

17.8B

294.0

1×50mm²+50mm²

7/3.10

1.4

63.10

13.10

19.68

410.2

1×70mm²+50mm²

19/2.22

1.4

6/3.10

1/3.10

21.38

574.3

1×95mm²+50mm²

19/2.59

1.4

6/3.10

13.10

22.98

704.5

2×10mm²+10mm²

7/1.35

1.0

6/1.35

1/1.35

12.30

120.7

2×16mm²+16mm²

7 /1.70

1.2

6/1.70

1/1.70

15.24

133.7

2×25mm²+25mm²

7/2.22

12

6/2.22

172.22

17.44

310.2

2×35mm²+35mm²

7/ 2.59

1.4

6/2.59

172.59

20.28

422.5

2×50mm²+50mm²

7/3.10

1.4

6/3.10

1/3.10

22.48

594.2

2×70mm²+50mm²

19/2.22

1.4

6/3.10

1/3.10

25.88

964.5

2×95mm²+50mm²

19/2.59

1.4

6/3.10

1/3.10

2908

1224.9

3×10mm²+10mm²

7/1.35

1.0

6/1.35

1/1.35

14.76

187.6

3×16mm²+16mm²

7/1.70

1.2

6/1.70

1/1.70

18.28

290.4

3×25mm²+25mm²

7/2.22

1.2

62.22

12.22

20.92

458.6

3×35mm²+35mm²

7/2.59

1.4

62.59

12.59

24.33

625.0

3×50mm²+50mm²

7/3.10

1.4

63.10

1/3.10

26.97

862.3

3×70mm²+50mm²

19/2.22

1.4

6/3.10

1/3.10

31.05

1354.7

3×95mm²+50mm²

19/2.59

1.4

6/3.10

1/3.10

34.89

1745.3


TANAMAN KAMI


ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228 IEC208 IEC502 Untuk Jalur Distribusi Udara 3

PROYEK

ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228 IEC208 IEC502 Untuk Jalur Distribusi Udara 4


MENGAPA KAMI?


ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228 IEC208 IEC502 Untuk Jalur Distribusi Udara 5


FAQ

T: Apa bentuk lengkap ACSR dalam Kabel ABC Self-Supporting ACSR?
J: ACSR adalah singkatan dari ‌Konduktor Aluminium Baja Diperkuat‌, yang menunjukkan kabel dengan konduktor aluminium dan inti baja untuk kekuatan mekanik

T: Berapakah peringkat tegangan maksimum untuk Kabel ABC Self-Supporting ACSR?
J: Biasanya diberi nilai untuk ‌33 kV hingga 230 kV‌, tergantung pada standar isolasi dan desain

T: Bagaimana inti baja meningkatkan kinerja kabel ACSR?
J: Inti baja menyediakan ‌kekuatan tarik tinggi‌, memungkinkan rentang yang lebih panjang di antara penyangga dan ketahanan terhadap beban angin/es

T: Bahan apa saja yang digunakan dalam isolasi Kabel ABC Self-Supporting?
J: Isolator umum termasuk ‌polietilena yang dihubungkan silang (XLPE)‌ atau ‌PVC‌, dengan ABC mengacu pada isolasi All-Black untuk ketahanan UV

T: Bisakah Kabel ABC Self-Supporting ACSR digunakan di daerah pesisir?
J: Ya, tetapi ‌inti baja galvanis‌ dan lapisan tahan korosi direkomendasikan untuk lingkungan air asin

T: Apa saja aplikasi umum dari kabel ini?
J: Digunakan dalam ‌transmisi daya udara‌, elektrifikasi pedesaan, dan jaringan industri karena daya tahan dan efektivitas biaya mereka

T: Bagaimana Anda menghitung lendutan kabel ACSR selama pemasangan?
J: Sag bergantung pada ‌panjang rentang, tegangan, dan suhu‌, dengan rumus yang disediakan dalam standar IEEE atau IEC

T: Perawatan apa yang diperlukan untuk Kabel ABC Self-Supporting ACSR?
J: Reguler ‌inspeksi visual‌ untuk korosi, kerusakan burung, dan kontaminasi isolator sangat penting

T: Bisakah kabel ini dikubur di bawah tanah?
J: Biasanya tidak dirancang untuk penguburan; gunakan ‌kabel bawah tanah‌ seperti XLPE untuk aplikasi tersebut









Rincian kontak
Zhongdong Cable Co., Ltd.

Kontak Person: Mr. Bai

Tel: +8619829885532

Mengirimkan permintaan Anda secara langsung kepada kami (0 / 3000)