CU/PVC/PVC Unarmoured Control Cable 0.6/1kV Copper Conductor PVC Insulated Sheathed Multi-core IEC 60502-1
| Type: | Unshielded Control Cable | Voltage Rating: | 0.6/1kV |
| Number of Cores: | 2-61 Cores | Conductor: | Copper, Class 1 / Class 2 / Class 5 (IEC 60228) |
| Insulation: | PVC | Outer Sheath: | PVC ST2 |
| Max Operating Temperature: | 70 Deg C | Standards: | IEC 60502-1 / IEC 60228 |
| Installation: | Indoor, Cable Trays, Conduits, Control Cabinets | Cross Reference: | VV / KVV Equivalent |
| High Light: | 0.6/1kV Rated Control Cable,Copper PVC PVC Construction,IEC 60502-1 Compliant Cable |
||
CU/PVC/PVC Control Cable 0.6/1kV
The CU/PVC/PVC 0.6/1kV control cable manufactured by Zhongdong Cable is designed for fixed control, monitoring, and auxiliary electrical applications in industrial, commercial, and infrastructure projects.
The cable consists of copper conductors, PVC insulation, and PVC outer sheath, providing reliable electrical performance, good flexibility, and economical installation. The simple and durable structure makes it suitable for general control circuits where electromagnetic shielding and additional mechanical protection are not required.
CU/PVC/PVC control cable is widely used in automation systems, electrical panels, machinery control circuits, and low-voltage control applications requiring stable and cost-effective cable solutions.
Quick Specs
- Type: Unshielded Control Cable
- Voltage Rating: 0.6/1kV
- Cores: Multi-core available (2-61 cores)
- Conductor: Copper, Class 1 / Class 2 / Class 5 (IEC 60228)
- Insulation: PVC (Polyvinyl Chloride)
- Outer Sheath: PVC ST2
- Configuration: Multi-core control cable
- Installation: Indoor, cable trays, conduits, control cabinets, and fixed installations
- Standards: IEC 60502-1 / IEC 60228
- Cross Reference: VV / KVV Equivalent (depending on application)
Construction
- Conductor: Plain annealed copper conductor, solid or stranded according to conductor size requirements.
- Insulation: PVC insulation provides electrical insulation and reliable operation at rated voltage.
- Assembly: Insulated cores are laid up together with suitable fillers (for multi-core cables) to form a compact cable structure.
- Outer Sheath: PVC sheath provides mechanical protection and resistance against moisture, abrasion, and outdoor conditions.
Applications
The CU/PVC/PVC 0.6/1kV control cable is designed for general control and low-voltage auxiliary circuits where shielding and armouring are not required. Typical applications include:
- Industrial control panels
- Electrical cabinets and switchboards
- Automation equipment wiring
- Machinery control systems
- Building control installations
- Motor control circuits
- HVAC and building management systems
- Factory production lines
- Auxiliary power and control connections
- Indoor fixed electrical installations
Standards
IEC 60502-1, IEC 60228
Technical Data (IEC 60502-1)
| No. of Cores x Section (No. x mm2) | Conductor Type | Insulation Thickness (mm) | Sheath Thickness (mm) | Overall Diameter (mm) | Approx. Weight (kg/km) | Max. D.C. Resistance at 20 deg C (ohm/km) |
| 2x0.5 | 2 | 0.6 | 1.8 | 8.1 | 74 | 36 |
| 2x1 | 2 | 0.6 | 1.8 | 8.9 | 98 | 18.1 |
| 2x1.5 | 2 | 0.8 | 1.8 | 10.3 | 131 | 12.1 |
| 2x2.5 | 2 | 0.8 | 1.8 | 11.1 | 157 | 7.41 |
| 2x6 | 2 | 1 | 1.8 | 14.1 | 265 | 3.08 |
| 4x0.5 | 2 | 0.6 | 1.8 | 9 | 97 | 36 |
| 4x1 | 2 | 0.6 | 1.8 | 9.9 | 138 | 18.1 |
| 4x1.5 | 2 | 0.8 | 1.8 | 11.6 | 191 | 12.1 |
| 4x2.5 | 2 | 0.8 | 1.8 | 12.6 | 240 | 7.41 |
| 4x6 | 2 | 1 | 1.8 | 16.2 | 445 | 3.08 |
| 7x0.5 | 2 | 0.6 | 1.8 | 10.2 | 131 | 36 |
| 7x1 | 2 | 0.6 | 1.8 | 11.4 | 182 | 18.1 |
| 7x1.5 | 2 | 0.8 | 1.8 | 13.5 | 259 | 12.1 |
| 7x2.5 | 2 | 0.8 | 1.8 | 14.7 | 341 | 7.41 |
| 7x6 | 2 | 1 | 1.8 | 19.2 | 657 | 3.08 |
| 10x0.5 | 2 | 0.6 | 1.8 | 12.3 | 179 | 36 |
| 10x1 | 2 | 0.6 | 1.8 | 13.9 | 252 | 18.1 |
| 10x1.5 | 2 | 0.8 | 1.8 | 16.7 | 360 | 12.1 |
| 10x2.5 | 2 | 0.8 | 1.8 | 18.3 | 478 | 7.41 |
| 10x6 | 2 | 1 | 1.8 | 24.3 | 932 | 3.08 |
| 12x0.5 | 2 | 0.6 | 1.8 | 12.6 | 195 | 36 |
| 12x1 | 2 | 0.6 | 1.8 | 14.3 | 280 | 18.1 |
| 12x1.5 | 2 | 0.8 | 1.8 | 17.2 | 406 | 12.1 |
| 12x2.5 | 2 | 0.8 | 1.8 | 18.9 | 543 | 7.41 |
| 12x6 | 2 | 1 | 1.8 | 25.1 | 1072 | 3.08 |
| 19x0.5 | 2 | 0.6 | 1.8 | 14.4 | 271 | 36 |
| 19x1 | 2 | 0.6 | 1.8 | 16.4 | 400 | 18.1 |
| 19x1.5 | 2 | 0.8 | 1.8 | 19.9 | 592 | 12.1 |
| 19x2.5 | 2 | 0.8 | 1.8 | 22 | 802 | 7.41 |
| 19x6 | 2 | 1 | 1.9 | 29.9 | 1643 | 3.08 |
| 24x0.5 | 2 | 0.6 | 1.8 | 16.5 | 338 | 36 |
| 24x1 | 2 | 0.6 | 1.8 | 18.8 | 500 | 18.1 |
| 24x1.5 | 2 | 0.8 | 1.8 | 23 | 739 | 12.1 |
| 24x2.5 | 2 | 0.8 | 1.8 | 25.6 | 1006 | 7.41 |
| 24x6 | 2 | 1 | 2 | 35.1 | 2084 | 3.08 |
| 37x0.5 | 2 | 0.6 | 1.8 | 18.6 | 464 | 36 |
| 37x1 | 2 | 0.6 | 1.8 | 21.3 | 707 | 18.1 |
| 37x1.5 | 2 | 0.8 | 1.8 | 26.2 | 1064 | 12.1 |
| 37x2.5 | 2 | 0.8 | 1.9 | 29.7 | 1485 | 7.41 |
| 37x6 | 2 | 1 | 2.2 | 40.6 | 3108 | 3.08 |
| 61x0.5 | 2 | 0.6 | 1.8 | 22.8 | 711 | 36 |
| 61x1 | 2 | 0.6 | 1.8 | 26.3 | 1102 | 18.1 |
| 61x1.5 | 2 | 0.8 | 2 | 33.3 | 1714 | 12.1 |
| 61x2.5 | 2 | 0.8 | 2.1 | 37.3 | 2386 | 7.41 |
| 61x6 | 2 | 1 | 2.6 | 51.6 | 5065 | 3.08 |
Representative technical data shown above. Complete data table covering all core counts (2-61 cores) and cross sections (0.5-10 mm2) is available upon request.
FAQ
Q1: What is CU/PVC/PVC control cable?
A: CU/PVC/PVC control cable is a low-voltage control cable consisting of copper conductors, PVC insulation, and PVC outer sheath. It is designed for general control, monitoring, and auxiliary electrical circuits.
Q2: What is the difference between CU/PVC/PVC and CU/PVC/CTS/PVC control cable?
A: CU/PVC/PVC is an unshielded cable for standard control applications, while CU/PVC/CTS/PVC includes a copper tape screen to improve protection against electromagnetic interference.
Q3: Where is CU/PVC/PVC control cable commonly used?
A: It is commonly used in control cabinets, industrial equipment, automation systems, building electrical installations, and general low-voltage control circuits.
Q4: Is CU/PVC/PVC control cable suitable for indoor installation?
A: Yes. It is widely used for indoor fixed installations such as control panels, electrical cabinets, and equipment wiring systems.
Q5: Can this cable be used for auxiliary power circuits?
A: Yes. Depending on the conductor size and project requirements, CU/PVC/PVC cable can be used for auxiliary power supply and control applications.
Q6: What conductor options are available for this cable?
A: The cable can be supplied with solid copper conductors (Class 1), stranded copper conductors (Class 2), or flexible copper conductors (Class 5) according to IEC 60228.
Q7: What is the maximum operating temperature of CU/PVC/PVC cable?
A: The PVC insulation allows continuous conductor operation up to 70 deg C under normal operating conditions.
Q8: Can CU/PVC/PVC control cable be customized for special applications?
A: Yes. Flame-retardant, low smoke zero halogen (LSZH), and other customized cable constructions can be supplied according to project requirements.