Kabel Kontrol Tahan Api CU/PVC/PVC 0.6/1kV Konduktor Tembaga Isolasi PVC Selubung Multi-inti IEC 60502-1
| Type: | Kabel Kontrol Tanpa Pelindung | Voltage Rating: | 0.6/1KV |
| Number of Cores: | 2-61 Inti | Conductor: | Tembaga, Kelas 1 / Kelas 2 / Kelas 5 (IEC 60228) |
| Insulation: | PVC | Outer Sheath: | Bahan PVC ST2 |
| Max Operating Temperature: | 70 derajat C | Standards: | IEC 60502-1 / IEC 60228 |
| Installation: | Dalam ruangan, baki kabel, saluran, lemari kontrol | Cross Reference: | Setara dengan VV/KVV |
| High Light: | Kabel Kontrol Terperingkat 0.6/1kV,Konstruksi Tembaga PVC PVC,Kabel Sesuai IEC 60502-1 |
||
CU/PVC/PVC Control Cable 0,6/1kV
CU/PVC/PVC 0.6/1kV kontrol kabel yang diproduksi oleh Zhongdong Kabel dirancang untuk kontrol tetap, pemantauan dan aplikasi listrik bantu di industri, komersial,dan proyek infrastruktur.
Kabel ini terdiri dari konduktor tembaga, isolasi PVC, dan lapisan luar PVC, memberikan kinerja listrik yang andal, fleksibilitas yang baik, dan instalasi yang ekonomis.Struktur sederhana dan tahan lama membuatnya cocok untuk sirkuit kontrol umum di mana perisai elektromagnetik dan perlindungan mekanis tambahan tidak diperlukan.
Kabel kontrol CU/PVC/PVC banyak digunakan dalam sistem otomatisasi, panel listrik, sirkuit kontrol mesin, dan aplikasi kontrol tegangan rendah yang membutuhkan solusi kabel yang stabil dan hemat biaya.
Spesifikasi Cepat
- Jenis:Kabel kontrol yang tidak dilindungi
- Nomor tegangan:0.6/1kV
- Inti:Multi-core tersedia (2-61 core)
- Konduktor:Tembaga, Kelas 1 / Kelas 2 / Kelas 5 (IEC 60228)
- Isolasi:PVC (Polyvinyl Chloride)
- Lapisan luar:PVC ST2
- Konfigurasi:Kabel kontrol multi-inti
- Pemasangan:Dalam ruangan, baki kabel, saluran, lemari kontrol, dan instalasi tetap
- Standar:IEC 60502-1 / IEC 60228
- Referensi silang:VV / KVV setara (tergantung pada aplikasi)
Konstruksi
- Konduktor:Konduktor tembaga yang dipanaskan biasa, padat atau bercabang sesuai dengan persyaratan ukuran konduktor.
- Isolasi:Isolasi PVC memberikan isolasi listrik dan operasi yang dapat diandalkan pada tegangan nominal.
- Pengumpulan:Inti terisolasi diletakkan bersama dengan pengisi yang cocok (untuk kabel multi-inti) untuk membentuk struktur kabel yang kompak.
- Lapisan luar:Lapisan PVC memberikan perlindungan mekanis dan ketahanan terhadap kelembaban, abrasi, dan kondisi luar ruangan.
Aplikasi
Kabel kontrol CU/PVC/PVC 0,6/1kV dirancang untuk kontrol umum dan sirkuit bantu tegangan rendah di mana perisai dan perisai tidak diperlukan.
- Panel kontrol industri
- Kabinet dan switchboard listrik
- Kabel peralatan otomatisasi
- Sistem kontrol mesin
- Instalasi kontrol bangunan
- Sirkuit kontrol motor
- Sistem HVAC dan manajemen bangunan
- Garis produksi pabrik
- Koneksi daya dan kontrol bantu
- Instalasi listrik tetap dalam ruangan
Standar
IEC 60502-1, IEC 60228
Data teknis (IEC 60502-1)
| Jumlah inti x Bagian (No. x mm2) | Jenis Konduktor | Ketebalan isolasi (mm) | Ketebalan sarung (mm) | Diameter keseluruhan (mm) | Berat (kg/km) | Max. DC resistance pada 20°C (ohm/km) |
| 2x0.5 | 2 | 0.6 | 1.8 | 8.1 | 74 | 36 |
| 2x1 | 2 | 0.6 | 1.8 | 8.9 | 98 | 18.1 |
| 2x1.5 | 2 | 0.8 | 1.8 | 10.3 | 131 | 12.1 |
| 2x2.5 | 2 | 0.8 | 1.8 | 11.1 | 157 | 7.41 |
| 2x6 | 2 | 1 | 1.8 | 14.1 | 265 | 3.08 |
| 4x0.5 | 2 | 0.6 | 1.8 | 9 | 97 | 36 |
| 4x1 | 2 | 0.6 | 1.8 | 9.9 | 138 | 18.1 |
| 4x1.5 | 2 | 0.8 | 1.8 | 11.6 | 191 | 12.1 |
| 4x2.5 | 2 | 0.8 | 1.8 | 12.6 | 240 | 7.41 |
| 4x6 | 2 | 1 | 1.8 | 16.2 | 445 | 3.08 |
| 7x0.5 | 2 | 0.6 | 1.8 | 10.2 | 131 | 36 |
| 7x1 | 2 | 0.6 | 1.8 | 11.4 | 182 | 18.1 |
| 7x1.5 | 2 | 0.8 | 1.8 | 13.5 | 259 | 12.1 |
| 7x2.5 | 2 | 0.8 | 1.8 | 14.7 | 341 | 7.41 |
| 7x6 | 2 | 1 | 1.8 | 19.2 | 657 | 3.08 |
| 10x0.5 | 2 | 0.6 | 1.8 | 12.3 | 179 | 36 |
| 10x1 | 2 | 0.6 | 1.8 | 13.9 | 252 | 18.1 |
| 10x1.5 | 2 | 0.8 | 1.8 | 16.7 | 360 | 12.1 |
| 10x2.5 | 2 | 0.8 | 1.8 | 18.3 | 478 | 7.41 |
| 10x6 | 2 | 1 | 1.8 | 24.3 | 932 | 3.08 |
| 12x0.5 | 2 | 0.6 | 1.8 | 12.6 | 195 | 36 |
| 12x1 | 2 | 0.6 | 1.8 | 14.3 | 280 | 18.1 |
| 12x1.5 | 2 | 0.8 | 1.8 | 17.2 | 406 | 12.1 |
| 12x2.5 | 2 | 0.8 | 1.8 | 18.9 | 543 | 7.41 |
| 12x6 | 2 | 1 | 1.8 | 25.1 | 1072 | 3.08 |
| 19x0.5 | 2 | 0.6 | 1.8 | 14.4 | 271 | 36 |
| 19x1 | 2 | 0.6 | 1.8 | 16.4 | 400 | 18.1 |
| 19x1.5 | 2 | 0.8 | 1.8 | 19.9 | 592 | 12.1 |
| 19x2.5 | 2 | 0.8 | 1.8 | 22 | 802 | 7.41 |
| 19x6 | 2 | 1 | 1.9 | 29.9 | 1643 | 3.08 |
| 24x0.5 | 2 | 0.6 | 1.8 | 16.5 | 338 | 36 |
| 24x1 | 2 | 0.6 | 1.8 | 18.8 | 500 | 18.1 |
| 24x1.5 | 2 | 0.8 | 1.8 | 23 | 739 | 12.1 |
| 24x2.5 | 2 | 0.8 | 1.8 | 25.6 | 1006 | 7.41 |
| 24x6 | 2 | 1 | 2 | 35.1 | 2084 | 3.08 |
| 37x0.5 | 2 | 0.6 | 1.8 | 18.6 | 464 | 36 |
| 37x1 | 2 | 0.6 | 1.8 | 21.3 | 707 | 18.1 |
| 37x1.5 | 2 | 0.8 | 1.8 | 26.2 | 1064 | 12.1 |
| 37x2.5 | 2 | 0.8 | 1.9 | 29.7 | 1485 | 7.41 |
| 37x6 | 2 | 1 | 2.2 | 40.6 | 3108 | 3.08 |
| 61x0.5 | 2 | 0.6 | 1.8 | 22.8 | 711 | 36 |
| 61x1 | 2 | 0.6 | 1.8 | 26.3 | 1102 | 18.1 |
| 61x1.5 | 2 | 0.8 | 2 | 33.3 | 1714 | 12.1 |
| 61x2.5 | 2 | 0.8 | 2.1 | 37.3 | 2386 | 7.41 |
| 61x6 | 2 | 1 | 2.6 | 51.6 | 5065 | 3.08 |
Data teknis representatif yang ditunjukkan di atas. Tabel data lengkap yang mencakup semua jumlah inti (2-61 inti) dan perpisahan (0,5-10 mm2) tersedia atas permintaan.
FAQ
Q1: Apa itu kabel kontrol CU/PVC/PVC?
A: Kabel kontrol CU/PVC/PVC adalah kabel kontrol tegangan rendah yang terdiri dari konduktor tembaga, isolasi PVC, dan lapisan luar PVC.dan sirkuit listrik bantu.
T2: Apa perbedaan antara kabel kontrol CU/PVC/PVC dan CU/PVC/CTS/PVC?
A: CU/PVC/PVC adalah kabel tanpa pelindung untuk aplikasi kontrol standar, sementara CU/PVC/CTS/PVC mencakup layar pita tembaga untuk meningkatkan perlindungan terhadap interferensi elektromagnetik.
T3: Di mana kabel kontrol CU/PVC/PVC biasanya digunakan?
A: Hal ini umumnya digunakan dalam kabinet kontrol, peralatan industri, sistem otomatisasi, bangunan instalasi listrik, dan sirkuit kontrol tegangan rendah umum.
T4: Apakah kabel kontrol CU/PVC/PVC cocok untuk instalasi dalam ruangan?
A: Ya. Ini banyak digunakan untuk instalasi tetap dalam ruangan seperti panel kontrol, lemari listrik, dan sistem kabel peralatan.
T5: Dapatkah kabel ini digunakan untuk sirkuit listrik bantu?
A: Ya. Tergantung pada ukuran konduktor dan persyaratan proyek, kabel CU/PVC/PVC dapat digunakan untuk pasokan listrik tambahan dan aplikasi kontrol.
T6: Pilihan konduktor apa yang tersedia untuk kabel ini?
A: Kabel dapat dilengkapi dengan konduktor tembaga padat (Kelas 1), konduktor tembaga berantai (Kelas 2), atau konduktor tembaga fleksibel (Kelas 5) menurut IEC 60228.
T7: Apa suhu operasi maksimum kabel CU/PVC/PVC?
A: Isolasi PVC memungkinkan operasi konduktor terus menerus hingga 70 derajat C dalam kondisi operasi normal.
Q8: Bisakah kabel kontrol CU/PVC/PVC disesuaikan untuk aplikasi khusus?
A: Ya. tahan api, asap rendah nol halogen (LSZH), dan konstruksi kabel khusus lainnya dapat disediakan sesuai dengan kebutuhan proyek.