Flame Retardant Control Cable 450/750V 4 Core Copper Tape Screen Steel Tape Armoured for Industrial Automation
| Voltage: | 450/750V | Conductor: | Copper |
| Screen: | Copper Braid | Armour: | STA |
| Insulation: | XLPE | Outer Sheath: | PVC |
Flame Retardant Control Cable 450/750V 4 Core Copper Tape Screen Steel Tape Armoured for Industrial Automation
Product Overview
Zhongdong Cable manufactures flame retardant control cables for industrial control systems, electrical equipment, and automation applications. This 450/750V 4 core control cable features copper conductors, flame retardant cable materials, a copper tape screening layer, and steel tape armour for applications requiring electrical control signal transmission, screening, and mechanical protection.
Designed for industrial environments where cable reliability and fire safety are important considerations, this cable combines a screened construction with armoured protection. It can be specified for control circuits, equipment connections, and industrial installations according to the project’s electrical, mechanical, and fire performance requirements.
As an experienced cable manufacturer, Zhongdong Cable supplies customized control cable solutions for cable distributors, electrical contractors, OEMs, system integrators, and EPC project procurement teams.
Key Features and Benefits
-
450/750V Rated Voltage: Suitable for control circuit applications designed for this voltage rating.
-
4 Core Construction: Supports multi-core control wiring and electrical equipment connections.
-
Copper Conductors: Provide good electrical conductivity for control circuit transmission.
-
Copper Tape Screen: Helps reduce the influence of external electromagnetic interference when properly designed and grounded.
-
Steel Tape Armour: Provides additional mechanical protection against external damage during suitable installation conditions.
-
Flame Retardant Design: Uses specified flame retardant cable materials to help limit flame propagation under the applicable test conditions.
-
Customized Manufacturing: Available with specified conductor sizes, insulation and sheath materials, screening construction, armour details, and cable marking.
Technical Specifications
|
Item |
Specification |
|---|---|
|
Product Name |
Flame Retardant Control Cable |
|
Rated Voltage |
450/750V |
|
Number of Cores |
4 Cores |
|
Conductor Material |
Copper |
|
Conductor Cross-Section |
According to project requirements |
|
Insulation Material |
To be specified |
|
Screening |
Copper Tape Screen |
|
Armour Type |
Steel Tape Armour |
|
Flame Retardant Performance |
According to the specified test standard and required class |
|
Outer Sheath Material |
To be specified |
|
Applicable Standard |
According to project requirements |
|
Operating Temperature |
According to the selected cable design |
|
Installation |
Fixed installation, subject to cable design and installation requirements |
Note: The final conductor size, conductor class, insulation and sheath materials, screen arrangement, armour structure, flame retardant classification, and applicable standard should be specified in the approved technical datasheet.
Cable Construction
1. Copper Conductor
The cable uses copper conductors to provide reliable electrical conductivity for control circuits. Conductor cross-sectional area and construction can be selected according to the required current, voltage drop, installation conditions, and project specification.
2. Insulation
The insulation separates individual conductors electrically and provides the required dielectric performance. The insulation material and thickness are selected according to the rated voltage and applicable product standard.
3. Core Identification
The four cores can be identified by numbered cores or agreed colour coding, depending on the project specification and applicable standard. This helps simplify installation, circuit identification, and maintenance.
4. Copper Tape Screen
The copper tape screen provides a conductive screening layer around the cable cores or core assembly, depending on the selected construction. It helps control electromagnetic interference when used with an appropriate grounding arrangement.
The screen design should be selected according to the application, grounding method, and required electrical performance.
5. Inner Sheath or Bedding
An inner sheath or bedding layer may be incorporated beneath the steel tape armour where required by the selected cable construction. Its material and thickness depend on the applicable standard and mechanical design.
6. Steel Tape Armour
Steel tape armour provides additional mechanical protection for suitable fixed-installation applications. It can help protect the cable against external mechanical damage during installation and service.
The suitability of steel tape armour depends on the installation environment. Where tensile loading, repeated movement, or special corrosion resistance is required, the armour and cable design should be reviewed accordingly.
7. Flame Retardant Outer Sheath
The outer sheath protects the cable assembly against external environmental influences. Flame retardant materials can be selected to meet the specified flame propagation requirements.
Flame retardant performance is test-specific. The required standard, test method, and classification should be agreed before production.
Typical Applications
Industrial Automation and Control Systems
Used for control wiring between industrial equipment, control panels, and electrical systems where a screened and armoured cable construction is required.
Manufacturing Plants and Industrial Facilities
Suitable for selected fixed-installation control circuits in manufacturing facilities, workshops, and industrial plants, subject to the cable design and installation conditions.
Electrical Equipment Connections
Can be specified for control connections between electrical equipment and associated control systems where four cores, copper tape screening, and steel tape armour meet the project requirements.
Infrastructure and Engineering Projects
Suitable for consideration in industrial infrastructure and engineering projects requiring flame retardant control cables with screening and mechanical protection.
Equipment and Machinery Control
Can be used for fixed control wiring in machinery and equipment installations where the specified cable construction and voltage rating are appropriate.
Important: This cable should not automatically be treated as a fire-resistant or circuit-integrity cable. Flame retardant performance limits flame propagation under specified test conditions; it does not necessarily guarantee continued circuit operation during a fire.
Flame Retardant Control Cable vs. Standard Control Cable
|
Feature |
Flame Retardant Control Cable |
Standard Control Cable |
|---|---|---|
|
Fire Performance |
Designed to meet specified flame propagation requirements |
Depends on the selected materials and applicable standard |
|
Copper Tape Screen |
Available in the specified construction |
Depends on cable design |
|
Steel Tape Armour |
Provides additional mechanical protection |
Depends on cable design |
|
Industrial Control Applications |
Suitable when electrical and installation requirements are met |
Suitable when electrical and installation requirements are met |
|
Customization |
Available according to project specifications |
Available according to project specifications |
The appropriate cable should be selected based on the required fire performance, electrical characteristics, screening requirements, mechanical protection, and installation conditions.
Why Choose Zhongdong Cable?
Experienced Cable Manufacturer
Zhongdong Cable Co., Ltd. has more than 20 years of cable manufacturing experience, serving customers in power distribution, industrial applications, infrastructure, and renewable energy markets.
Broad Product Range
Our product portfolio includes power cables, control cables, solar cables, medium-voltage and high-voltage cables, aerial bundled cables, and bare conductors.
Quality Management Systems
Our factory operates under ISO 9001, ISO 14001, and ISO 45001 management systems. Product inspection and testing are arranged according to the applicable product standard and agreed technical requirements.
Customized OEM Supply
We support cable distributors, wholesalers, electrical contractors, equipment manufacturers, and EPC companies with customized cable specifications, production arrangements, export packaging, and shipment coordination.
International Project Support
Our sales team assists customers with specification review, quotation preparation, technical documentation, cable drum requirements, and international delivery arrangements.
Customization Options
Zhongdong Cable can review the following requirements for project-specific production:
-
Number of cores and conductor cross-sectional area
-
Copper conductor class and construction
-
Insulation material and thickness
-
Copper tape screen structure and coverage
-
Inner sheath or bedding requirements
-
Steel tape armour construction
-
Flame retardant classification and test requirements
-
Outer sheath material, colour, and thickness
-
Applicable product standard and inspection requirements
-
Cable length, drum dimensions, and export packaging
-
Cable marking and customer-specific identification
Final construction details should be agreed upon before quotation and production.
Frequently Asked Questions
1.What is a flame retardant control cable?
A flame retardant control cable is designed to meet specified flame propagation requirements. It is used in control circuits where limiting the spread of fire along a cable route is an important consideration.
2.What is the function of the copper tape screen?
The copper tape screen provides a conductive screening layer that can help reduce electromagnetic interference when correctly designed and grounded. Its effectiveness depends on the screen construction, grounding arrangement, and installation environment.
3.What is the advantage of steel tape armour?
Steel tape armour provides additional mechanical protection for suitable fixed installations. It helps protect the cable from certain forms of external mechanical damage, but it is not a substitute for proper cable routing and installation protection.
4.Is flame retardant cable the same as fire-resistant cable?
No. Flame retardant cable is designed to limit flame propagation under specified test conditions. Fire-resistant cable is designed to maintain circuit integrity for a specified period under defined fire test conditions. The required performance should be identified clearly in the project specification.
5. Can this cable be manufactured to a specific standard?
The applicable standard depends on the required cable construction, voltage rating, fire performance, and destination market. Zhongdong Cable can review the requested standard and technical specification before confirming the proposed design.
What information is required for a quotation?
For an accurate quotation, please provide the following details where available:
-
Required conductor cross-sectional area
-
Total quantity and cable length
-
Applicable standard and flame retardant classification
-
Required insulation and outer sheath materials
-
Copper tape screen requirements
-
Steel tape armour requirements
-
Delivery destination and preferred trade terms
-
Cable drum and packaging requirements
If your project has an existing specification or bill of quantities, you can send it to our sales team for review.