logo

Flame Retardant Control Cable 450/750V 4 Core Copper Tape Screen Steel Tape Armoured for Industrial Automation

Basic Properties
Place of Origin: Hebei, China
Brand Name: OEM
Certification: ISO, IEC,CE,EAC
Model Number: CU/XLPE/CBS/CTS/PVC
Trading Properties
Minimum Order Quantity: Negotiable
Price: Negotiable
Payment Terms: L/C,T/T
Supply Ability: 100km/week
Specifications
Voltage: 450/750V Conductor: Copper
Screen: Copper Braid Armour: STA
Insulation: XLPE Outer Sheath: PVC
Product Description

Flame Retardant Control Cable 450/750V 4 Core Copper Tape Screen Steel Tape Armoured for Industrial Automation


Product Overview

Zhongdong Cable manufactures flame retardant control cables for industrial control systems, electrical equipment, and automation applications. This 450/750V 4 core control cable features copper conductors, flame retardant cable materials, a copper tape screening layer, and steel tape armour for applications requiring electrical control signal transmission, screening, and mechanical protection.

Designed for industrial environments where cable reliability and fire safety are important considerations, this cable combines a screened construction with armoured protection. It can be specified for control circuits, equipment connections, and industrial installations according to the project’s electrical, mechanical, and fire performance requirements.

As an experienced cable manufacturer, Zhongdong Cable supplies customized control cable solutions for cable distributors, electrical contractors, OEMs, system integrators, and EPC project procurement teams.


Key Features and Benefits

  • 450/750V Rated Voltage: Suitable for control circuit applications designed for this voltage rating.

  • 4 Core Construction: Supports multi-core control wiring and electrical equipment connections.

  • Copper Conductors: Provide good electrical conductivity for control circuit transmission.

  • Copper Tape Screen: Helps reduce the influence of external electromagnetic interference when properly designed and grounded.

  • Steel Tape Armour: Provides additional mechanical protection against external damage during suitable installation conditions.

  • Flame Retardant Design: Uses specified flame retardant cable materials to help limit flame propagation under the applicable test conditions.

  • Customized Manufacturing: Available with specified conductor sizes, insulation and sheath materials, screening construction, armour details, and cable marking.


Technical Specifications

Item

Specification

Product Name

Flame Retardant Control Cable

Rated Voltage

450/750V

Number of Cores

4 Cores

Conductor Material

Copper

Conductor Cross-Section

According to project requirements

Insulation Material

To be specified

Screening

Copper Tape Screen

Armour Type

Steel Tape Armour

Flame Retardant Performance

According to the specified test standard and required class

Outer Sheath Material

To be specified

Applicable Standard

According to project requirements

Operating Temperature

According to the selected cable design

Installation

Fixed installation, subject to cable design and installation requirements

Note: The final conductor size, conductor class, insulation and sheath materials, screen arrangement, armour structure, flame retardant classification, and applicable standard should be specified in the approved technical datasheet.


Cable Construction

1. Copper Conductor

The cable uses copper conductors to provide reliable electrical conductivity for control circuits. Conductor cross-sectional area and construction can be selected according to the required current, voltage drop, installation conditions, and project specification.

2. Insulation

The insulation separates individual conductors electrically and provides the required dielectric performance. The insulation material and thickness are selected according to the rated voltage and applicable product standard.

3. Core Identification

The four cores can be identified by numbered cores or agreed colour coding, depending on the project specification and applicable standard. This helps simplify installation, circuit identification, and maintenance.

4. Copper Tape Screen

The copper tape screen provides a conductive screening layer around the cable cores or core assembly, depending on the selected construction. It helps control electromagnetic interference when used with an appropriate grounding arrangement.

The screen design should be selected according to the application, grounding method, and required electrical performance.

5. Inner Sheath or Bedding

An inner sheath or bedding layer may be incorporated beneath the steel tape armour where required by the selected cable construction. Its material and thickness depend on the applicable standard and mechanical design.

6. Steel Tape Armour

Steel tape armour provides additional mechanical protection for suitable fixed-installation applications. It can help protect the cable against external mechanical damage during installation and service.

The suitability of steel tape armour depends on the installation environment. Where tensile loading, repeated movement, or special corrosion resistance is required, the armour and cable design should be reviewed accordingly.

7. Flame Retardant Outer Sheath

The outer sheath protects the cable assembly against external environmental influences. Flame retardant materials can be selected to meet the specified flame propagation requirements.

Flame retardant performance is test-specific. The required standard, test method, and classification should be agreed before production.


Typical Applications

Industrial Automation and Control Systems

Used for control wiring between industrial equipment, control panels, and electrical systems where a screened and armoured cable construction is required.

Manufacturing Plants and Industrial Facilities

Suitable for selected fixed-installation control circuits in manufacturing facilities, workshops, and industrial plants, subject to the cable design and installation conditions.

Electrical Equipment Connections

Can be specified for control connections between electrical equipment and associated control systems where four cores, copper tape screening, and steel tape armour meet the project requirements.

Infrastructure and Engineering Projects

Suitable for consideration in industrial infrastructure and engineering projects requiring flame retardant control cables with screening and mechanical protection.

Equipment and Machinery Control

Can be used for fixed control wiring in machinery and equipment installations where the specified cable construction and voltage rating are appropriate.

Important: This cable should not automatically be treated as a fire-resistant or circuit-integrity cable. Flame retardant performance limits flame propagation under specified test conditions; it does not necessarily guarantee continued circuit operation during a fire.


Flame Retardant Control Cable vs. Standard Control Cable

Feature

Flame Retardant Control Cable

Standard Control Cable

Fire Performance

Designed to meet specified flame propagation requirements

Depends on the selected materials and applicable standard

Copper Tape Screen

Available in the specified construction

Depends on cable design

Steel Tape Armour

Provides additional mechanical protection

Depends on cable design

Industrial Control Applications

Suitable when electrical and installation requirements are met

Suitable when electrical and installation requirements are met

Customization

Available according to project specifications

Available according to project specifications

The appropriate cable should be selected based on the required fire performance, electrical characteristics, screening requirements, mechanical protection, and installation conditions.


Why Choose Zhongdong Cable?

Experienced Cable Manufacturer

Zhongdong Cable Co., Ltd. has more than 20 years of cable manufacturing experience, serving customers in power distribution, industrial applications, infrastructure, and renewable energy markets.

Broad Product Range

Our product portfolio includes power cables, control cables, solar cables, medium-voltage and high-voltage cables, aerial bundled cables, and bare conductors.

Quality Management Systems

Our factory operates under ISO 9001, ISO 14001, and ISO 45001 management systems. Product inspection and testing are arranged according to the applicable product standard and agreed technical requirements.

Customized OEM Supply

We support cable distributors, wholesalers, electrical contractors, equipment manufacturers, and EPC companies with customized cable specifications, production arrangements, export packaging, and shipment coordination.

International Project Support

Our sales team assists customers with specification review, quotation preparation, technical documentation, cable drum requirements, and international delivery arrangements.


Customization Options

Zhongdong Cable can review the following requirements for project-specific production:

  • Number of cores and conductor cross-sectional area

  • Copper conductor class and construction

  • Insulation material and thickness

  • Copper tape screen structure and coverage

  • Inner sheath or bedding requirements

  • Steel tape armour construction

  • Flame retardant classification and test requirements

  • Outer sheath material, colour, and thickness

  • Applicable product standard and inspection requirements

  • Cable length, drum dimensions, and export packaging

  • Cable marking and customer-specific identification

Final construction details should be agreed upon before quotation and production.


Frequently Asked Questions

1.What is a flame retardant control cable?

A flame retardant control cable is designed to meet specified flame propagation requirements. It is used in control circuits where limiting the spread of fire along a cable route is an important consideration.

2.What is the function of the copper tape screen?

The copper tape screen provides a conductive screening layer that can help reduce electromagnetic interference when correctly designed and grounded. Its effectiveness depends on the screen construction, grounding arrangement, and installation environment.

3.What is the advantage of steel tape armour?

Steel tape armour provides additional mechanical protection for suitable fixed installations. It helps protect the cable from certain forms of external mechanical damage, but it is not a substitute for proper cable routing and installation protection.

4.Is flame retardant cable the same as fire-resistant cable?

No. Flame retardant cable is designed to limit flame propagation under specified test conditions. Fire-resistant cable is designed to maintain circuit integrity for a specified period under defined fire test conditions. The required performance should be identified clearly in the project specification.

5. Can this cable be manufactured to a specific standard?

The applicable standard depends on the required cable construction, voltage rating, fire performance, and destination market. Zhongdong Cable can review the requested standard and technical specification before confirming the proposed design.


What information is required for a quotation?

For an accurate quotation, please provide the following details where available:

  • Required conductor cross-sectional area

  • Total quantity and cable length

  • Applicable standard and flame retardant classification

  • Required insulation and outer sheath materials

  • Copper tape screen requirements

  • Steel tape armour requirements

  • Delivery destination and preferred trade terms

  • Cable drum and packaging requirements

If your project has an existing specification or bill of quantities, you can send it to our sales team for review.