logo
Tìm thấy 215 sản phẩm cho "

armoured power cable

"
Chất lượng Cáp an toàn cháy điện áp trung bình với các dây dẫn rào PVC Nhà máy

Cáp an toàn cháy điện áp trung bình với các dây dẫn rào PVC

Medium Voltage Fire Resistant Cable with PVC Sheathed Stranded Conductors Application Fire resistant cables can be used in several critical buildings where safety against fire is mandatory to reduce the risk of death as: Hospitals & Old people’shomes. Schools & Recreational buildings. Museums & Historical places. Undergrounds & Tunnels. Railways & Airports. Shopping Centers & Malls. Theatres & Cinemas. Hotels & Offices. High-rise buildings Construction Stranded co

Chất lượng Thép băng bọc thép STA Cáp chống cháy Cáp điều khiển PVC Nhà máy

Thép băng bọc thép STA Cáp chống cháy Cáp điều khiển PVC

Steel Tape Armoured STA Fire Resistant Flame Retardant PVC Sheathed Control Cable Application ‌Industrial Plants ‌ Power Distribution Systems ‌ ‌High-Risk Buildings ‌Transportation Infrastructure ‌ ‌Hazardous Environments ‌ ‌Emergency Systems ‌ Construction Conductor: Solid or Stranded Copper Conductor Insualtion: XLPE Inner Sheath: PVC Armor: Steel Tape Sheath: Flame Retardant PVC Description Rated voltage 450/750V or less,The control cable can be made as flame retardant

Chất lượng Cáp LSZH điện áp thấp AL/ XLPE/AWA/SWA/PVC NA2XRH IEC 60502-1 Nhà máy

Cáp LSZH điện áp thấp AL/ XLPE/AWA/SWA/PVC NA2XRH IEC 60502-1

Low Voltage LSZH Cable AL/ XLPE/AWA/SWA/PVC NA2XRH IEC 60502-1 APPLICATION LSZH cable with steel wire armour (SWA) is used in power networks, underground, outdoor, indoor applications and in cable ducting. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. CONSTRUCTION Conductor :Class 2 stranded aluminium conductor Insulation :XLPE (Cross-Linked Polyethylene) Filler : LSZH (Low Smoke Zero Halogen) Armour :Single core:

Chất lượng Đường dây cáp điện áp thấp lõi duy nhất 0.6KV 1kV PVC băng thép cách nhiệt STA bọc thép Nhà máy

Đường dây cáp điện áp thấp lõi duy nhất 0.6KV 1kV PVC băng thép cách nhiệt STA bọc thép

Single Core Low Voltage Cable 0.6/1kV PVC insulated Steel tape Armored STA Application The cables are mainly used in energy networks with sudden load change residental or industrial areas. Can be laid outdoors, under grounds and in areas where sudden mechanical stress are expected Construction Conductor:Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation:PVC Filler: Non-hygroscopic material Inner sheath: PVC Outer Sheath PVC Technical data The

Chất lượng 18/30kV 19/33kV SWA Cáp điện áp trung bình Single Core PVC Jacket YJV32 YJLV42 Nhà máy

18/30kV 19/33kV SWA Cáp điện áp trung bình Single Core PVC Jacket YJV32 YJLV42

18/30kV 19/33kV SWA Medium Voltage Cable Single Core PVC Jacket YJV32 YJLV42 Application Mine environments: In mines, cables need to withstand large mechanical stresses and harsh environmental conditions. The thick steel wire armor and good insulation performance of YJV42 cable enable it to operate safely and reliably in mines, providing power support for mining equipment. Industrial installations: Suitable for various industrial settings where reliable power transmission is

Chất lượng CU XLPE STA PVC MV Cáp ngầm tiêu chuẩn IEC 18/30kV dây điện áp trung bình Nhà máy

CU XLPE STA PVC MV Cáp ngầm tiêu chuẩn IEC 18/30kV dây điện áp trung bình

CU/XLPE/SWA/PVC Medium Voltage Cable 18/30kV IEC Standard Underground Cable Application The cables are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground as well as for installation on cable trays for industries, switchboards and power stations Construction Conductor: Class 2 Aluminium/Copper circular, stranded Conductor Screen: Semi-conductive XLPE (Cross-Linked Polyethylene) Insulation : XLPE (Cross-Linked Polyethyle

Chất lượng 8.7KV 15kV Cáp điện áp trung bình Khói thấp Không Halogen LSZH chống cháy Nhà máy

8.7KV 15kV Cáp điện áp trung bình Khói thấp Không Halogen LSZH chống cháy

Low Smoke Zero Halogen Medium Voltage Cable LSZH Fire Resistant 8.7/15kV Application ‌Urban Infrastructure ‌:Underground power distribution networks in cities, tunnels, and subways where fire resistance and low smoke emission are critical for evacuation and rescue. ‌Commercial and High-Rise Buildings ‌:Main power supply systems, emergency circuits, and riser shafts in offices, hotels, and residential towers to comply with strict fire safety regulations. ‌Public Transportation

Chất lượng Sợi dây đồng màn hình điện áp thấp cáp đơn lõi 0.6/1kV PVC cách điện cáp Nhà máy

Sợi dây đồng màn hình điện áp thấp cáp đơn lõi 0.6/1kV PVC cách điện cáp

Copper Wire Screen Low Voltage Cable Single Core 0.6/1kV PVC Insulated Cable APPLICATION Copper-shielded low-voltage cables are widely used in environments requiring reliable power transmission with electromagnetic interference (EMI) protection CONSTRUCTION Conductor:Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation:XLPE Filler: Non-hygroscopic material Screen: Copper Wire Binder tape:: Non-hygroscopic material Sheath PVC Characteristics Test

Chất lượng N2XBY NA2XBY 3 lõi Cáp điện áp thấp 0.6/1kV 0.5~800MM2 lV Nhà máy

N2XBY NA2XBY 3 lõi Cáp điện áp thấp 0.6/1kV 0.5~800MM2 lV

N2XBY NA2XBY Low Voltage Cable 3 Core 0.6/1kV 0.5 ~ 800MM2 Construction Conductor: Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation: XLPE Filler: non-hygroscopic material Binder tape: non-hygroscopic material Sheath: PVC Characteristics Test Voltage: 3.5kV 5min No Breakdown The ambient temperature for installation: ≥0℃. Maximum conductor temperature in normal operation:≤90℃. Max operating temperature of con. When cable short-circuited(5s