logo
Trovato 215 prodotti per "

armoured power cable

"
Qualità Cavi per la sicurezza antincendio a media tensione con conduttori a fili avvolti in PVC Fabbrica

Cavi per la sicurezza antincendio a media tensione con conduttori a fili avvolti in PVC

Medium Voltage Fire Resistant Cable with PVC Sheathed Stranded Conductors Application Fire resistant cables can be used in several critical buildings where safety against fire is mandatory to reduce the risk of death as: Hospitals & Old people’shomes. Schools & Recreational buildings. Museums & Historical places. Undergrounds & Tunnels. Railways & Airports. Shopping Centers & Malls. Theatres & Cinemas. Hotels & Offices. High-rise buildings Construction Stranded co

Qualità Cable anti-incendio STA blindato con nastro d'acciaio Cable di controllo con involucro in PVC Fabbrica

Cable anti-incendio STA blindato con nastro d'acciaio Cable di controllo con involucro in PVC

Steel Tape Armoured STA Fire Resistant Flame Retardant PVC Sheathed Control Cable Application ‌Industrial Plants ‌ Power Distribution Systems ‌ ‌High-Risk Buildings ‌Transportation Infrastructure ‌ ‌Hazardous Environments ‌ ‌Emergency Systems ‌ Construction Conductor: Solid or Stranded Copper Conductor Insualtion: XLPE Inner Sheath: PVC Armor: Steel Tape Sheath: Flame Retardant PVC Description Rated voltage 450/750V or less,The control cable can be made as flame retardant

Qualità Cable LSZH a bassa tensione AL/ XLPE/AWA/SWA/PVC NA2XRH IEC 60502-1 Fabbrica

Cable LSZH a bassa tensione AL/ XLPE/AWA/SWA/PVC NA2XRH IEC 60502-1

Low Voltage LSZH Cable AL/ XLPE/AWA/SWA/PVC NA2XRH IEC 60502-1 APPLICATION LSZH cable with steel wire armour (SWA) is used in power networks, underground, outdoor, indoor applications and in cable ducting. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. CONSTRUCTION Conductor :Class 2 stranded aluminium conductor Insulation :XLPE (Cross-Linked Polyethylene) Filler : LSZH (Low Smoke Zero Halogen) Armour :Single core:

Qualità Cavo a basso voltaggio a nucleo singolo filo 0,6KV 1kV PVC nastro di acciaio isolante blindato STA Fabbrica

Cavo a basso voltaggio a nucleo singolo filo 0,6KV 1kV PVC nastro di acciaio isolante blindato STA

Single Core Low Voltage Cable 0.6/1kV PVC insulated Steel tape Armored STA Application The cables are mainly used in energy networks with sudden load change residental or industrial areas. Can be laid outdoors, under grounds and in areas where sudden mechanical stress are expected Construction Conductor:Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation:PVC Filler: Non-hygroscopic material Inner sheath: PVC Outer Sheath PVC Technical data The

Qualità 18/30kV 19/33kV SWA Cavo a media tensione Single Core PVC Jacket YJV32 YJLV42 Fabbrica

18/30kV 19/33kV SWA Cavo a media tensione Single Core PVC Jacket YJV32 YJLV42

18/30kV 19/33kV SWA Medium Voltage Cable Single Core PVC Jacket YJV32 YJLV42 Application Mine environments: In mines, cables need to withstand large mechanical stresses and harsh environmental conditions. The thick steel wire armor and good insulation performance of YJV42 cable enable it to operate safely and reliably in mines, providing power support for mining equipment. Industrial installations: Suitable for various industrial settings where reliable power transmission is

Qualità CU XLPE STA PVC MV cavo sotterraneo IEC standard 18/30kV cavo a media tensione Fabbrica

CU XLPE STA PVC MV cavo sotterraneo IEC standard 18/30kV cavo a media tensione

CU/XLPE/SWA/PVC Medium Voltage Cable 18/30kV IEC Standard Underground Cable Application The cables are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground as well as for installation on cable trays for industries, switchboards and power stations Construction Conductor: Class 2 Aluminium/Copper circular, stranded Conductor Screen: Semi-conductive XLPE (Cross-Linked Polyethylene) Insulation : XLPE (Cross-Linked Polyethyle

Qualità 8.7KV 15kV Cavo a media tensione a basso fumo a zero alogeni LSZH resistente al fuoco Fabbrica

8.7KV 15kV Cavo a media tensione a basso fumo a zero alogeni LSZH resistente al fuoco

Low Smoke Zero Halogen Medium Voltage Cable LSZH Fire Resistant 8.7/15kV Application ‌Urban Infrastructure ‌:Underground power distribution networks in cities, tunnels, and subways where fire resistance and low smoke emission are critical for evacuation and rescue. ‌Commercial and High-Rise Buildings ‌:Main power supply systems, emergency circuits, and riser shafts in offices, hotels, and residential towers to comply with strict fire safety regulations. ‌Public Transportation

Qualità Cable a bassa tensione a filo di rame Cable isolato in PVC a singolo nucleo 0,6/1kV Fabbrica

Cable a bassa tensione a filo di rame Cable isolato in PVC a singolo nucleo 0,6/1kV

Copper Wire Screen Low Voltage Cable Single Core 0.6/1kV PVC Insulated Cable APPLICATION Copper-shielded low-voltage cables are widely used in environments requiring reliable power transmission with electromagnetic interference (EMI) protection CONSTRUCTION Conductor:Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation:XLPE Filler: Non-hygroscopic material Screen: Copper Wire Binder tape:: Non-hygroscopic material Sheath PVC Characteristics Test

Qualità N2XBY NA2XBY 3 Core Cavo a bassa tensione 0.6/1kV 0.5~800MM2 1V Fabbrica

N2XBY NA2XBY 3 Core Cavo a bassa tensione 0.6/1kV 0.5~800MM2 1V

N2XBY NA2XBY Low Voltage Cable 3 Core 0.6/1kV 0.5 ~ 800MM2 Construction Conductor: Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation: XLPE Filler: non-hygroscopic material Binder tape: non-hygroscopic material Sheath: PVC Characteristics Test Voltage: 3.5kV 5min No Breakdown The ambient temperature for installation: ≥0℃. Maximum conductor temperature in normal operation:≤90℃. Max operating temperature of con. When cable short-circuited(5s