Tinned Copper DC Photovoltaic Solar Cable for Solar Panels 4mm2 6mm2 10mm2 16mm2 1000V 1500V
| Uv Resistance: | Yes | Insulation Material: | Cross-linked Polyethylene (XLPE) |
| Certifications: | TUV, UL, CE | Conductor Material: | Tinned Copper |
| Halogen Free: | Yes | Application: | Solar Power Systems |
| High Light: | tinned copper photovoltaic solar cable,4mm2 tinned copper solar pv cable |
||
Tinned Copper Dc Pv Photovoltaic Solar Wire Cable for Solar Panels 4mm2 6mm2 10mm2 16mm2 1000V 1500V
Application
Solar cables are specially designed for connecting photovoltaic system components, whether indoors or outdoors. They excel in environments with high mechanical demands and extreme weather conditions.
Cable performance
Properties such as moisture and heat resistance, high and low temperature resistance, acid and alkali resistance,ozone resistance, UV resistance, flame retardancy, etc
Description
- AC rated voltage(U0/U):0.6/1.0kV
- DC rated volate(U0):1.8kV
- Minimum bending radius: Φ ≦ 12mm:3XD Φ > 12mm:4XD
- Maximum Voltage: Ambient Temperature: -40℃ ℃~ +90℃
- Short Circuit Temperature: 200℃/5 sec
Thermal Properties:
- Maximum Voltage: Ambient Temperature: -40ºC ~ +90ºC
- Maximum Temperature at Conductor: 120ºC (20000h) according to IEC/EN 60216-1
- Short Circuit Temperature: 200ºC/5 seconds
- Thermal Endurance Test: According to EN 60216-2 (temperature index +120° C)
- High Temperature Pressure Test: According to EN 60811-3-1
- Damp-Heat Resistance: According to EN 60068-2-78 with 85% humidity
Specifications
Cable structure parameters
|
Cross section(mm²) |
Conductor Construction(no/mm) |
Conductor Stranded OD.max(mm) |
Cable OD.(mm) |
Approximate weight of cable |
Max Cond Resistance(Ω/km,20°C) |
|
1×1.5 |
48/0.20 |
1.58 |
4.8 |
35 |
13.7 |
|
1×2.5 |
77/0.20 |
2.02 |
5.2 |
47 |
8.21 |
|
1×4 |
56/0.285 |
2.46 |
5.7 |
64 |
5.09 |
|
1×6 |
84/0.285 |
3.01 |
6.3 |
86 |
3.39 |
|
1×10 |
77/0.40 |
4.1 |
7.2 |
128 |
1.95 |
|
1×16 |
7×17/0.40 |
5.5 |
8.9 |
196 |
1.24 |
|
1×25 |
7×27/0.40 |
6.7 |
10.7 |
299 |
0.795 |
|
1×35 |
7×38/0.40 |
8.2 |
12.4 |
407 |
0.565 |
|
1×50 |
19×20/0.40 |
10.0 |
14.6 |
571 |
0.393 |
|
1×70 |
19×28/0.40 |
11.6 |
16.4 |
773 |
0.277 |
|
1×95 |
19×38/0.40 |
13.5 |
18.5 |
1024 |
0.210 |
|
1×120 |
24×38/0.40 |
14.4 |
19.8 |
1266 |
0.164 |
|
1×150 |
30×38/0.40 |
16.2 |
22.2 |
1584 |
0.132 |
|
1×185 |
37×38/0.40 |
18.2 |
25.0 |
1967 |
0.108 |
|
1×240 |
48×38/0.40 |
20.6 |
27.8 |
2518 |
0.0817 |
Long term allowable current carrying capacity
|
Installation method |
Single cable in air |
Single cable on object surface |
Two contacting cables on object surface |
|
Cross section(mm²) |
Carrying capacity(A) |
||
|
1.5 |
30 |
29 |
24 |
|
2.5 |
41 |
39 |
33 |
|
4 |
55 |
52 |
44 |
|
6 |
70 |
67 |
57 |
|
10 |
98 |
93 |
79 |
|
16 |
132 |
125 |
107 |
|
25 |
176 |
167 |
142 |
|
35 |
218 |
207 |
176 |
|
50 |
276 |
262 |
221 |
|
70 |
347 |
330 |
278 |
|
95 |
416 |
395 |
333 |
|
120 |
488 |
464 |
390 |
|
150 |
566 |
538 |
453 |
|
185 |
644 |
612 |
515 |
|
240 |
775 |
736 |
620 |
|
Operation temperature |
120℃ |
||
|
Ambient temperature |
60℃ |
||
Correction and Adjustment Factors
|
Ambient temperature(℃)(air) |
≦60 |
70 |
80 |
90 |
100 |
110 |
|
Correction factor |
1 |
0.91 |
0.82 |
0.71 |
0.58 |
0.41 |
-
Kreally good support and professional