Copper Wire Screen Low Voltage Cable Single Core 0.6/1kV PVC Insulated Cable
| Voltage: | 0.6/1kV | Insulation: | XLPE |
| Jacket: | PVC | Feature: | LSZH |
| Screen: | Copper Wire | Application: | Underground, Overhead, Indoor, Mining And Power Distribution Etc |
| High Light: | Low Voltage PVC Insulated Cable,Copper Wire Screen Low Voltage Cable,Low Voltage Cable Single Core |
||
Copper Wire Screen Low Voltage Cable Single Core 0.6/1kV PVC Insulated Cable
APPLICATION
Copper-shielded low-voltage cables are widely used in environments requiring reliable power transmission with electromagnetic interference (EMI) protection
CONSTRUCTION
- Conductor:Circular, solid, compacted or sector shaped stranded Copper or aluminum
- Insulation:XLPE
- Filler: Non-hygroscopic material
- Screen: Copper Wire
- Binder tape:: Non-hygroscopic material
- Sheath PVC
Characteristics
- Test Voltage: 3.5kV 5min No Breakdown
- The ambient temperature for installation: ≥0℃.
- Maximum conductor temperature in normal operation:≤90℃.
- Max operating temperature of con. When cable short-circuited(5s maximum duration): 250℃.
- Permissible minimum bending radius:
- Single unarmoured cable: 20 x OD
- Multi-core unarmoured cable: 15 x OD
- Single armoured cable: 5 x OD
- Multi-core armoured cable: 12 x OD
- Note : OD=Overall Diameter of Cable
SPECIFICATION
|
Nominal section area |
Approx. overall diameter |
Approx. weight of cable |
Maximum DC resistance of the conductor |
||
|
mm2 |
mm |
kg/km |
Ω/km |
||
|
|
|
Cu |
Al |
20℃ Cu |
20℃ Al |
|
1×1.5 RE |
5.8 |
49.3 |
– |
12.1 |
– |
|
1×2.5 RE |
6.2 |
62.2 |
46.6 |
7.41 |
12.1 |
|
1×4 RE |
7.1 |
86.4 |
61.6 |
4.61 |
7.41 |
|
1×6 RE |
7.6 |
109.8 |
72.6 |
3.08 |
4.61 |
|
1×10 CC |
8.6 |
156.7 |
94.8 |
1.83 |
3.08 |
|
1×16 CC |
9.6 |
221 |
122 |
1.15 |
1.91 |
|
1×25 CC |
11.2 |
324.1 |
169.4 |
0.727 |
1.2 |
|
1×35 CC |
12.2 |
426.8 |
210.2 |
0.524 |
0.868 |
|
1×50 CC |
14 |
586 |
276.6 |
0.387 |
0.641 |
|
1×70 CC |
15.7 |
787.5 |
354.4 |
0.268 |
0.443 |
|
1×95 CC |
17.7 |
1050.5 |
462.7 |
0.193 |
0.32 |
|
1×120 CC |
19.3 |
1298.2 |
555.7 |
0.153 |
0.253 |
|
1×150 CC |
21.3 |
1611.6 |
683.6 |
0.124 |
0.206 |
|
1×185 CC |
23.6 |
1977.4 |
832.8 |
0.0991 |
0.164 |
|
1×240 CC |
26.4 |
2537.7 |
1052.9 |
0.0754 |
0.125 |
|
1×300 CC |
29.1 |
3146.2 |
1290.1 |
0.0601 |
0.1 |
|
1×400 CC |
32.7 |
4140.8 |
1666 |
0.047 |
0.0778 |
|
1×500 CC |
36.3 |
5142.2 |
2048.7 |
0.0366 |
0.0605 |
|
1×630 CC |
40 |
6395.4 |
2497.6 |
0.0283 |
0.0469 |
Application Scenarios



ABOUT US

APPLICATION

WHY CHOOSE US

PARTNER