Steel Tape STA Low Smoke Halogen Free Cable Class 2 Conductor N2X2Y Flame Retardant
| Voltage: | 3.6/6kV | Insulation: | XLPE |
| Jacket: | PVC | Feature: | LSZH |
| Amour: | Steel Tape | Application: | Underground, Overhead, Indoor, Mining And Power Distribution Etc |
| High Light: | Steel Tape Low Smoke Halogen Free Cable,Flame Retardant Low Smoke Halogen Free Cable |
||
Steel Tape STA Low Smoke Zero Halogen Cable Class 2 conductor N2X2Y
Application
- Flame-retardant low-smoke zero-halogen (LSZH/LSOH) cables are widely applied in various critical scenarios due to their enhanced safety and environmental features:
- Transportation Systems:Deployed in metro systems, light rail transit, and aviation facilities to ensure safe power transmission while minimizing toxic emissions during fire incidents
- Public Infrastructure: Used in hospitals, schools, high-rise buildings, and commercial complexes to reduce smoke and hazardous gas release, aiding evacuation and firefighting
- Industrial Facilities:Installed in petrochemical plants, mining operations, and power stations where fire risks demand cables with superior flame resistance and minimal corrosive combustion byproducts
- Energy and Utilities:Employed in nuclear power plants, transformer stations, and electrical distribution systems to maintain operational integrity under extreme conditions
- Confined Public Spaces:Utilized in air-handling spaces (e.g., ceilings, raised floors) of airports, subway stations, and office buildings to restrict smoke spread and improve visibility during emergencies
Construction
- Conductor :Class 2 stranded copper conductor
- Insulation :XLPE (Cross-Linked Polyethylene)
- Bedding :LSZH (Low Smoke Zero Halogen)
- Armour :STA (Steel Tape Armour)
- Sheath :LSZH (Low Smoke Zero Halogen)
Advantage
- Composite high temperature resistance performance
- Compressive and tensile strengthening
- LSZH jacket
- Anti bending and anti deformation
- Electromagnetic and Environmental Adaptability
- Low frequency interference shielding
- Chemical corrosion protection
- Direct burial without conduit
- Extended lifespan
Specification
|
No.cores x |
Insulation |
Inner Sheath |
Sheath |
Outer Ø |
weight |
Current ratings in air 30℃ |
Current ratings buried 20℃ |
|
mm² |
mm |
mm |
mm |
mm |
kg / km |
A |
A |
|
3 x 35 |
2.5 |
1.3 |
2.3 |
43.5 |
2993 |
144 |
181 |
|
3 x 50 |
2.5 |
1.3 |
2.4 |
46.5 |
3601 |
172 |
215 |
|
3 x 70 |
2.5 |
1.4 |
2.5 |
49.3 |
4368 |
213 |
263 |
|
3 x 95 |
2.5 |
1.4 |
2.6 |
54.3 |
5348 |
261 |
315 |
|
3 x 120 |
2.5 |
1.5 |
2.8 |
57.9 |
6303 |
301 |
358 |
|
3 x 150 |
2.5 |
1.6 |
2.9 |
61.7 |
7405 |
341 |
402 |
|
3 x 185 |
2.5 |
1.6 |
3.0 |
65.4 |
8646 |
392 |
456 |
|
3 x 240 |
2.6 |
1.7 |
3.2 |
70.7 |
10573 |
459 |
527 |
|
3 x 300 |
2.8 |
1.8 |
3.4 |
77.3 |
12779 |
532 |
599 |
|
3 x 400 |
3.0 |
2.0 |
3.7 |
88.1 |
17225 |
624 |
685 |