logo
발견 379 제품 "

xlpe insulated cable

"
품질 6/10kV 전압 및 알루미늄 합금 8000 시리즈 도체를 사용한 맞춤형 길이 알루미늄 전력 케이블 공장

6/10kV 전압 및 알루미늄 합금 8000 시리즈 도체를 사용한 맞춤형 길이 알루미늄 전력 케이블

Custom Length Aluminium Power Cable AL/XLPE/STA SWA/PVC NA2XRY NA2X2Y Applications Industrial Power Distribution: Suitable for factories, manufacturing plants, and heavy machinery Infrastructure Projects: Used in construction, tunnels, bridges, and underground installations Renewable Energy: Deployed in solar and wind farms for power transmission Urban Networks: Applied in urban power grids, street lighting, and public facilities Cable Construction Conductor: Round compacted

품질 100% 절연 MV 케이블 1X630mm2 구리 도체 XLPE 절연 25kV 공장

100% 절연 MV 케이블 1X630mm2 구리 도체 XLPE 절연 25kV

100% Insulated MV Cable 1X630mm2 Copper Conductor XLPE Insulated 25kV Applications The cable is used to transmit large amounts of electrical power at 25 kV from substations to industrial or infrastructure loads. Construction Conductor: Compacted conductors Conductor Shield: Semi conductive tape+semi conductive shielding material Insulation: XLPE Insulation Shield: Peelable semiconducting shielding material Metal Shield Layer: Copper Tape Filler: Polypropylene (PP) m esh f

품질 NF C 33-209 인증된 에어리얼 팩들드 케이블 XLPE 단열 0.6/1kV 3x150+1x95 공장

NF C 33-209 인증된 에어리얼 팩들드 케이블 XLPE 단열 0.6/1kV 3x150+1x95

NF C 33-209 Certified Aerial Bundled Cable XLPE Insulated 0.6/1kV 3x150+1x95 Application Primarily used for overhead service applications such as street lighting, outdoor lighting, and temporary service for construction. To be used at voltages of 0.6/1kV and at conductor temperatures not to exceed 90°C for cross-linked polyethylene (XLPE) insulated conductors. Construction Conductor : Stranded, circular compacted, circular compressed AAC or AAAC. Insulation : Cross-linked

품질 OEM 8.7-15KV 중전압 케이블 XLPE 단열 STA NA2XSY NA2XS2Y NA2XS(F) 2Y N2XSEY 공장

OEM 8.7-15KV 중전압 케이블 XLPE 단열 STA NA2XSY NA2XS2Y NA2XS(F) 2Y N2XSEY

8.7-15KV Medium Voltage Power Cable XLPE Insulated STA NA2XSY NA2XS2Y NA2XS(F)2Y N2XSEY Application Medium voltage power cable for static application in ground, within and outside facilities, outdoor, in cable canals,in water, in conditions where cables are not exposed to heavier mechanical stress and tensile strain.. Construction Conductor: Circular compacted stranded Copper or aluminium Conductor screen: Extruded semi-conductive compound Insulation: XLPE Insulation screen:

품질 69kV 구리 와이어 스크린 HV 전력 케이블 IEC 60840 표준 XLPE 단열 공장

69kV 구리 와이어 스크린 HV 전력 케이블 IEC 60840 표준 XLPE 단열

69kV Copper Wire Screen High Voltage Cable for IEC 60840 standard Application Cables are suitable for use in high voltage transmission networks, in systems of rated voltages from 60 kV grade up to and including 69kV grade. Construction Stranded circular or segmental (Milliken) compacted copper conductor, extruded semi-conducting layer as a conductor screen, XLPE insulation,extruded semi-conducting layer as an insulation screen, semi-conductive swelling tape, helically applied

품질 6 8 10 가이브 AWG 크기 알루미늄 선도자 전력 케이블 AA8000 XLPE 단열 XHHW XHHW-2 공장

6 8 10 가이브 AWG 크기 알루미늄 선도자 전력 케이블 AA8000 XLPE 단열 XHHW XHHW-2

6 8 10 Gauge AWG Size Aluminum Conductor Cable AA8000 XLPE Insulation XHHW XHHW-2 Application XHHW-2 is primarily used in house construction, conduit, or recognized raceways for services, feeders, and branch circuit wiring in wet or dry locations, at temperatures not to exceed 90°C. Voltage rating is 600V. This product is designed to be installed without the application of pulling lubricant. . Construction Conductor: Aluminum Alloy Insulation: 120℃ XLPE/XLPO Jacket: XLPE, PVC

품질 600V XLPE 단열 에어리얼 뱅들드 케이블 ABC 오버헤드 트위스트 케이블 공장

600V XLPE 단열 에어리얼 뱅들드 케이블 ABC 오버헤드 트위스트 케이블

600V XLPE Insulation ABC Aerial Bundled Cable and Overhead Twisted Cable Applicatiom Low voltage aerial cable is designed to supply 600/1000-volt aerial service for temporary service at construction sites, as a service drop (power pole to service entrance), as a secondary cable (pole to pole) or street lighting. This over-head cable provides reinforced insulation acc. Characteristics Voltage rating: 1kV Test voltage: 4kV, 5min no breakdown. Operating temperature PVC: -15°C to

품질 3.6/6kV 26/35kV 중전압 케이블 XLPE 단열 금속 테이프 장갑 전력 케이블 공장

3.6/6kV 26/35kV 중전압 케이블 XLPE 단열 금속 테이프 장갑 전력 케이블

3.6/6kV~26/35kV Medium Voltage Cable XLPE Insulation PVC Sheath Metal Tape Armouring Power Cable Application Suitable for urban underground power grids, power station outgoing lines, internal power supply lines of industrial and mining enterprises, etc. CONSTRUCTION Conductor: Round compacted conductors Conductor Shield: Semi conductive shielding material (below 500mm Semi conductive tape+semi conductive shielding material (500 mm 2 and above) Insulation: Polyvinyl chloride

품질 IEC 60502-2 XLPE 단열 알루미늄 장갑 3X300mm 3X150mm 불 retardant 전력 케이블 공장

IEC 60502-2 XLPE 단열 알루미늄 장갑 3X300mm 3X150mm 불 retardant 전력 케이블

IEC 60502-2 XLPE Insulated Aluminium Armoured 3X300mm 3X150mm Flame Retardant Power Cable Applications The cables arewidely used in places such as wind farms and solar power stations to meet the power transmission needs of these places ‌ Main Technical Properties 1. DC resistance of conductor at 20°C : not exceed ing 0.1 Ω/km; 2. 4h Power Frequency Voltage Test (4U₀) : No breakdown occurred; 3. 50Hz AC Withstand Voltage Test: 65 kV for 30 min ; No breakdown occurred; 4.

이전