xlpe insulated cable
"
1000kcmil 알루미늄 케이블 100% XLPE 절연 25kV 산업 또는 기반 시설 부하용
1000kcmil Aluminium Cable 100% XLPE Insulated 25kV for Industrial or Infrastructure Loads Applications The cable is designed for medium-voltage primary distribution systems, suitable for heavy industrial loads and infrastructure projects requiring reliable high-capacity power transmission. Construction 1. Conductor: copper or aluminum. 2. Provide armored and unarmoured power cables. 3. Rated voltage Medium voltage: 6kV (um=7.2kv) -30kv (um=36kv) 4. PVC or polyethylene sheath.
4 코어 PE 전력 케이블 구리 코어 XLPE 절연 N2X2Y IEC60852-1 표준
4 Core PE Power Cable Cu Core XLPE Insulated N2X2Y IEC60852-1 Standard APPLICATION PE Power cables are used for low-voltage power distribution (0.6/1 kV) in fixed installations, suitable for indoor and outdoor laying including cable trays, ducts, and conduits, and used in supplying buildings, industrial equipment, and general electrical loads. CONSTRUCTION Type: N2X2Y Conductor: Copper (Cu) Insulation: Cross-Linked Polyethylene (XLPE) Sheath: PE CHARACTERISTIC Rated voltage:
Black Copper Conductor Low Voltage Cable XLPE Insulated PVC Sheathed Custom 로고
YJV Copper Conductor Low Voltage Cable XLPE Insulated PVC Sheathed Application These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage. Construction 1. Conductor: Copper/Aluminum/Aluminum Alloy 2. Insulation: Cross-linked polyethylene XLPE 3
구리 코어 태양 전지 패널 케이블 PV 케이블 XLPE 단열 PV1-F 케이블 UV 저항
Copper Core Solar Cable Solar Panel Cable PV Cable XLPE Insulated PV1-F Cable Application For DC photovoltaic cables Series connection between photovoltaic modules Parallel connection between strings and between strings and DC distribution box (combiner box) Connection between DC distribution box and inverter. For AC photovoltaic cables Connecting inverters to step-up transformers The connection between the step-up transformer and the distribution equipment; The connection
XLPE 단열 4 코어 열 저항 케이블 불 retardant 전력 케이블 OEM
XLPE Insulation Fire Resistant Cable Flame Retardant sheath Power cable 4 Core Application Fire resistant cables can be used in several critical buildings where safety against fire is mandatory to reduce the risk of death as: Hospitals & Old people’shomes. Schools & Recreational buildings. Museums & Historical places. Undergrounds & Tunnels. Railways & Airports. Shopping Centers & Malls. Theatres & Cinemas. Hotels & Offices. High-rise buildings Construction C ondu
IEC 60502 N2XH 저연소 제로 할로겐 LSZH 케이블 XLPE 단열 0.6KV 1kV
IEC 60502 N2XH Low Smoke Zero Halogen Cable XLPE Insulated 0.6/1kV Application Low smoke zero halogen cables are becoming more popular in military applications, aircraft, railway and maritime. This is because in these areas it is often difficult to ventilate in the event of a fire.. Besides, Low smoke halogen free material is also widely used in high pressure underground tunnels or track marking lines in railway system. when using them, reduces the possibility of harmful
XLPE 단열 알루미늄 선도 케이블 강철 와이어 장갑 PVC 껍질 8.7KV 15kV
8.7/15kV Aluminium Conductor Cable Steel Wire Armoured XLPE Insulated PVC Sheath Cable Application Distribution and signalling power cable for static outdoor application (with protection against direct UV-irradiation), in ground, in water, within facilities, in cable canals, in concrete, in conditions requiring increased electric protection and protection against mechanical damages. Used in electric power plants, transformer stations, industrial plants, metropolitan networks
구리 와이어 스크린 110kV 고전압 전송 케이블 XLPE 단열 LSHF 재킷
Copper Wire Screen 110kV High Voltage Cable XLPE Insulation LSHF Jacket Cable Application Used for underground power transmission lines; laid on cable ladder, tray, buried direct in the ground or in duct in the ground Construction 1.Conductor 2.Conductor screen 3.XLPE insulation 4.Insulation screen 5.Semiconducting tape 6.Copper wire screen 7.Aluminum laminated tape 8.PE or PVC outer sheath (Graphite coating or extruded semiconducting) Description Voltage Rating (Uo/U)(Um) :
불 retardant 저연소 제로 할로겐 케이블 0.6KV 1kV XLPE 단열 YJY23
Flame Retardant Low Smoke Zero Halogen Cable 0.6/1kV XLPE Insulated YJY23 Application Industrial Factory Power Distribution Systems High-Risk Buildings Transportation Infrastructure Hazardous Environments Emergency Systems Construction Conductor :Class 2 stranded copper conductor Insulation :XLPE (Cross-Linked Polyethylene) Bedding :LSZH (Low Smoke Zero Halogen) Armour :SWA (Steel Wire Armour) Sheath :LSZH (Low Smoke Zero Halogen) Advantage Composite high