xlpe insulated cable
"
สายไฟฟ้าอัลลูมิเนียมความยาวตามสั่ง พร้อมความกระชับ 6/10kV และสายไฟฟ้าอัลลูมิเนียมสลอก 8000 ซีรีส์
Custom Length Aluminium Power Cable AL/XLPE/STA SWA/PVC NA2XRY NA2X2Y Applications Industrial Power Distribution: Suitable for factories, manufacturing plants, and heavy machinery Infrastructure Projects: Used in construction, tunnels, bridges, and underground installations Renewable Energy: Deployed in solar and wind farms for power transmission Urban Networks: Applied in urban power grids, street lighting, and public facilities Cable Construction Conductor: Round compacted
100% ไฮโล MV Cable 1X630mm2 ทองแดง LED XLPE ไฮโล 25kV
100% Insulated MV Cable 1X630mm2 Copper Conductor XLPE Insulated 25kV Applications The cable is used to transmit large amounts of electrical power at 25 kV from substations to industrial or infrastructure loads. Construction Conductor: Compacted conductors Conductor Shield: Semi conductive tape+semi conductive shielding material Insulation: XLPE Insulation Shield: Peelable semiconducting shielding material Metal Shield Layer: Copper Tape Filler: Polypropylene (PP) m esh f
สายเคเบิลหุ้มฉนวน XLPE มาตรฐาน NF C 33-209 แรงดันไฟฟ้า 0.6/1kV ขนาด 3x150+1x95
NF C 33-209 Certified Aerial Bundled Cable XLPE Insulated 0.6/1kV 3x150+1x95 Application Primarily used for overhead service applications such as street lighting, outdoor lighting, and temporary service for construction. To be used at voltages of 0.6/1kV and at conductor temperatures not to exceed 90°C for cross-linked polyethylene (XLPE) insulated conductors. Construction Conductor : Stranded, circular compacted, circular compressed AAC or AAAC. Insulation : Cross-linked
OEM 8.7-15KV สายไฟฟ้าความดันกลาง XLPE ติดต่อ STA NA2XSY NA2XS2Y NA2XS(F) 2Y N2XSEY
8.7-15KV Medium Voltage Power Cable XLPE Insulated STA NA2XSY NA2XS2Y NA2XS(F)2Y N2XSEY Application Medium voltage power cable for static application in ground, within and outside facilities, outdoor, in cable canals,in water, in conditions where cables are not exposed to heavier mechanical stress and tensile strain.. Construction Conductor: Circular compacted stranded Copper or aluminium Conductor screen: Extruded semi-conductive compound Insulation: XLPE Insulation screen:
69kV สกรีนสายทองแดง HV สายไฟฟ้า IEC 60840 Standard XLPE Insulation
69kV Copper Wire Screen High Voltage Cable for IEC 60840 standard Application Cables are suitable for use in high voltage transmission networks, in systems of rated voltages from 60 kV grade up to and including 69kV grade. Construction Stranded circular or segmental (Milliken) compacted copper conductor, extruded semi-conducting layer as a conductor screen, XLPE insulation,extruded semi-conducting layer as an insulation screen, semi-conductive swelling tape, helically applied
6 8 10 Gauge AWG ขนาดแอลูมิเนียมสายไฟฟ้าสายนํา AA8000 XLPE ติดกัน XHHW XHHW-2
6 8 10 Gauge AWG Size Aluminum Conductor Cable AA8000 XLPE Insulation XHHW XHHW-2 Application XHHW-2 is primarily used in house construction, conduit, or recognized raceways for services, feeders, and branch circuit wiring in wet or dry locations, at temperatures not to exceed 90°C. Voltage rating is 600V. This product is designed to be installed without the application of pulling lubricant. . Construction Conductor: Aluminum Alloy Insulation: 120℃ XLPE/XLPO Jacket: XLPE, PVC
600V XLPE แอร์เรียล บันเดิลเคเบิ้ล ABC Overhead Twisted Cable
600V XLPE Insulation ABC Aerial Bundled Cable and Overhead Twisted Cable Applicatiom Low voltage aerial cable is designed to supply 600/1000-volt aerial service for temporary service at construction sites, as a service drop (power pole to service entrance), as a secondary cable (pole to pole) or street lighting. This over-head cable provides reinforced insulation acc. Characteristics Voltage rating: 1kV Test voltage: 4kV, 5min no breakdown. Operating temperature PVC: -15°C to
3.6/6kV26/35kV สายไฟฟ้าความดันกลาง XLPE เทปโลหะประกอบความหนาว
3.6/6kV~26/35kV Medium Voltage Cable XLPE Insulation PVC Sheath Metal Tape Armouring Power Cable Application Suitable for urban underground power grids, power station outgoing lines, internal power supply lines of industrial and mining enterprises, etc. CONSTRUCTION Conductor: Round compacted conductors Conductor Shield: Semi conductive shielding material (below 500mm Semi conductive tape+semi conductive shielding material (500 mm 2 and above) Insulation: Polyvinyl chloride
IEC 60502-2 XLPE แอลูมิเนียมประกอบกันความร้อน 3X300mm 3X150mm
IEC 60502-2 XLPE Insulated Aluminium Armoured 3X300mm 3X150mm Flame Retardant Power Cable Applications The cables arewidely used in places such as wind farms and solar power stations to meet the power transmission needs of these places Main Technical Properties 1. DC resistance of conductor at 20°C : not exceed ing 0.1 Ω/km; 2. 4h Power Frequency Voltage Test (4U₀) : No breakdown occurred; 3. 50Hz AC Withstand Voltage Test: 65 kV for 30 min ; No breakdown occurred; 4.