AACSR Overhead Conductor 500 kV Steel-Reinforced Bare Cable
Properti Dasar
Tempat Asal:
Hebei, Cina
Nama Merek:
AACSR Overhead Conductor
Sertifikasi:
CCC,IEC,VDE,TUV,ISO
Nomor Model:
AACSR
Properti Perdagangan
Jumlah Pesanan Minimum:
Bisa dinegosiasikan
Harga:
dapat dinegosiasikan
Ketentuan Pembayaran:
, L/c, t/t
Kemampuan Pasokan:
500 km/minggu
Spesifikasi
| Range Of Application: | Transmisi overhead, tanah overhead | Material: | ACSR |
| Drum Packing: | Drum kayu baja | Product Name: | ACSR Rabbit Conductor Dog Conductor |
| Type: | konduktor telanjang | Standard: | IEC, BS, ICEA, ASTM, DIN |
| High Light: | Konduktor udara AACSR 500kV,Kabel aluminium bertulang baja,konduktor telanjang dengan garansi |
||
Deskripsi Produk
Konduktor Overhead AACSR (Aluminum Alloy Conductor Steel Reinforced)
APLIKASI
Kabel AACSR banyak digunakan dalam:
- Transmisi daya jarak jauh: Mencakup lebih dari 100 km dengan kendur minimal
- Jaringan tegangan tinggi: Dinilai untuk tegangan hingga 500 kV (misalnya, koneksi gardu induk)
- Elektrifikasi pedesaan: Hemat biaya untuk daerah terpencil dengan geografi yang menantang
- Kawat pembawa: Mendukung kabel komunikasi overhead di jaringan telekomunikasi
KONSTRUKSI
AACSR (Kabel Konduktor Aluminium Diperkuat Baja) adalah konduktor saluran transmisi overhead berkapasitas tinggi yang terdiri dari:
- Inti baja: Memberikan kekuatan mekanik untuk menopang bentang panjang dan mengurangi kendur
- Lapisan aluminium: Untaian aluminium kemurnian tinggi yang dililitkan secara konsentris di sekitar inti baja, memastikan konduktivitas yang sangat baik
KARAKTERISTIK
- Konduktivitas tinggi: Aluminium memastikan transmisi daya yang efisien dengan resistansi yang lebih rendah
- Ringan & tahan korosi: Aluminium mengurangi berat dan tahan terhadap degradasi lingkungan
- Hemat biaya: Biaya material lebih rendah dibandingkan dengan tembaga, ideal untuk proyek skala besar
- Daya tahan: Inti baja meningkatkan kekuatan tarik untuk medan yang keras (misalnya, sungai, pegunungan)
SPESIFIKASI
| Nomor Kode | Rasio Baja | Area | Jumlah Kawat | Dia. Kawat | Diameter | Massa Linear | Kekuatan Terukur | D.C.Resistance pada 20℃ | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Alum. | St. | Total | Alum. | St. | Alum. | St. | Inti | Konduktor | |||||
| 16 | 17 | 18.4 | 3.07 | 21.5 | 6 | 1 | 1.98 | 1.98 | 1.98 | 5.93 | 74.4 | 9.02 | 1.7934 |
| 25 | 17 | 28.8 | 4.80 | 33.6 | 6 | 1 | 2.47 | 2.47 | 2.47 | 7.41 | 116.2 | 13.96 | 1.1478 |
| 40 | 17 | 46.0 | 7.67 | 53.7 | 6 | 1 | 3.13 | 3.13 | 3.13 | 9.38 | 185.9 | 22.02 | 0.7174 |
| 63 | 17 | 72.5 | 12.1 | 84.6 | 6 | 1 | 3.92 | 3.92 | 3.92 | 11.8 | 292.8 | 34.68 | 0.4555 |
| 400 | 6 | 115 | 6.39 | 121 | 18 | 1 | 2.85 | 2.85 | 2.85 | 14.3 | 366.4 | 41.24 | 0.2880 |
| 425 | 6 | 144 | 7.99 | 152 | 18 | 1 | 3.19 | 3.19 | 3.19 | 16.0 | 458.0 | 51.23 | 0.2304 |
| 425 | 16 | 144 | 23.4 | 167 | 26 | 7 | 2.65 | 2.06 | 6.19 | 16.8 | 579.9 | 69.86 | 0.2310 |
| 160 | 6 | 184 | 10.2 | 194 | 18 | 1 | 3.61 | 3.61 | 3.61 | 18.0 | 586.2 | 65.58 | 0.1800 |
| 160 | 16 | 184 | 30.0 | 214 | 26 | 7 | 3.0 | 2.34 | 7.01 | 19.0 | 742.3 | 88.52 | 0.1805 |
| 200 | 6 | 230 | 12.8 | 243 | 18 | 1 | 4.04 | 4.04 | 4.04 | 20.2 | 732.8 | 81.97 | 0.1440 |
| 200 | 16 | 230 | 37.5 | 268 | 26 | 7 | 3.36 | 2.61 | 7.83 | 21.3 | 927.9 | 110.64 | 0.1444 |
| 250 | 10 | 288 | 28.3 | 316 | 22 | 7 | 4.08 | 2.27 | 6.80 | 23.1 | 1013.5 | 117.9 | 0.1154 |
| 250 | 16 | 288 | 46.9 | 335 | 26 | 7 | 3.75 | 2.92 | 8.76 | 23.8 | 1159.8 | 138.31 | 0.1155 |
| 315 | 7 | 363 | 25.1 | 388 | 45 | 7 | 3.20 | 2.14 | 6.41 | 25.6 | 1196.5 | 136.28 | 0.0917 |
| 315 | 16 | 363 | 59.0 | 422 | 26 | 7 | 4.21 | 3.28 | 9.83 | 26.7 | 1461.4 | 171.90 | 0.0917 |
| 400 | 7 | 460 | 31.8 | 492 | 45 | 7 | 3.61 | 2.41 | 7.22 | 28.9 | 1519.4 | 172.10 | 0.0722 |
| 400 | 13 | 460 | 59.7 | 520 | 54 | 7 | 3.29 | 3.29 | 9.88 | 29.7 | 1938.3 | 201.46 | 0.0723 |
| 450 | 7 | 518 | 35.8 | 554 | 45 | 7 | 3.83 | 2.55 | 7.66 | 30.6 | 1709.0 | 193.61 | 0.0642 |
| 450 | 13 | 518 | 67.1 | 585 | 54 | 7 | 3.49 | 3.49 | 10.5 | 31.5 | 1955.6 | 226.64 | 0.0643 |
| 500 | 7 | 575 | 39.8 | 615 | 45 | 7 | 4.04 | 2.69 | 8.07 | 32.3 | 1899.3 | 215.12 | 0.0578 |
| 500 | 13 | 575 | 74.6 | 650 | 54 | 7 | 3.68 | 3.68 | 11.1 | 33.2 | 2172.9 | 251.82 | 0.0578 |
| 560 | 7 | 645 | 44.6 | 689 | 45 | 7 | 4.27 | 2.85 | 8.54 | 34.2 | 2127.2 | 240.93 | 0.0516 |
| 560 | 13 | 645 | 81.6 | 726 | 54 | 19 | 3.90 | 2.34 | 11.7 | 35.1 | 2420.9 | 283.21 | 0.0516 |
| 630 | 4 | 725 | 31.3 | 756 | 72 | 7 | 3.58 | 2.39 | 7.16 | 35.8 | 2248.0 | 249.62 | 0.0459 |
| 630 | 13 | 725 | 91.8 | 817 | 54 | 19 | 4.13 | 2.48 | 12.4 | 37.2 | 2723.5 | 318.61 | 0.0459 |
| 710 | 817 | 35.3 | 852 | 72 | 7 | 3.80 | 2.53 | 7.60 | 38.0 | 2533.4 | 281.32 | 0.0407 | |
| 710 | 13 | 817 | 104 | 921 | 54 | 19 | 4.39 | 2.63 | 13.2 | 39.5 | 3069.4 | 359.06 | 0.0407 |
| 800 | 4 | 921 | 39.8 | 961 | 72 | 7 | 4.04 | 2.69 | 8.07 | 40.4 | 2854.6 | 316.98 | 0.0361 |
| 800 | 8 | 921 | 76.7 | 997 | 84 | 7 | 3.74 | 3.74 | 11.2 | 41.1 | 3145.1 | 356.03 | 0.0362 |
| 900 | 4 | 1036 | 44.8 | 1081 | 72 | 7 | 4.28 | 2.85 | 8.56 | 42.8 | 3211.4 | 356.60 | 0.0321 |
| 900 | 8 | 1036 | 86.3 | 1122 | 84 | 7 | 3.96 | 3.93 | 11.9 | 43.6 | 3538.3 | 400.53 | 0.0322 |
| 1000 | 8 | 1151 | 93.7 | 1245 | 84 | 19 | 4.18 | 2.51 | 12.5 | 45.9 | 3916.8 | 446.37 | 0.0289 |
| 1120 | 8 | 1289 | 105 | 1394 | 84 | 19 | 4.42 | 2.65 | 13.3 | 48.6 | 4386.8 | 499.93 | 0.0258 |
Tentang kami

Proyek Kami

Pusat Uji Kami

FAQ
1. Apa kegunaan kabel AACSR?
AACSR (Aluminum Conductor Steel-Reinforced) terutama digunakan untuk transmisi daya overhead tegangan tinggi (hingga 500 kV) karena rasio kekuatan terhadap beratnya, ideal untuk bentang panjang di seberang sungai, pegunungan, atau daerah pedesaan.
2. Mengapa memilih AACSR daripada ACSR?
AACSR menggantikan beberapa untaian aluminium dengan lapisan paduan aluminium, menawarkan konduktivitas yang lebih tinggi (3% lebih baik daripada ACSR) sambil mempertahankan kekuatan tarik, mengurangi kehilangan energi pada jarak tertentu.
3. Apa peran inti baja?
Inti baja galvanis memberikan kekuatan mekanik untuk menahan beban angin, es, dan ekspansi termal, meminimalkan kendur pada suhu ekstrem.
4. Berapa batas suhunya?
Suhu pengoperasian terus-menerus: 90°C (194°F). Kelebihan beban darurat: 180°C (356°F) untuk durasi singkat.
5. Bagaimana cara menghitung ampacity AACSR?
Gunakan standar IEEE 738, dengan mempertimbangkan suhu sekitar, diameter konduktor (misalnya, 26,8 mm untuk tipe Drake), dan kecepatan angin.
6. Apakah AACSR tahan korosi?
Ya, tetapi inti baja galvanis di daerah pesisir mungkin memerlukan lapisan paduan seng-aluminium untuk umur panjang yang lebih baik.
7. Rentang khas untuk pemasangan AACSR?
Medan datar: 300-500 meter. Pegunungan/lembah: 50-200 meter (karena variasi tegangan).
8. Kepatuhan standar?
Memenuhi IEC 61089, ASTM B232, dan EN 50182, dengan sertifikasi ISO 9001 opsional untuk manufaktur yang dikontrol kualitas.
9. Perbandingan biaya dengan kabel tembaga?
AACSR 60-70% lebih murah daripada tembaga, dengan konduktivitas yang sama, menjadikannya pilihan yang lebih disukai untuk proyek skala utilitas.
10. Bagaimana cara menyimpan gulungan AACSR?
Di dalam ruangan: Hindari kelembapan; simpan gulungan di atas palet. Di luar ruangan: Tutupi dengan terpal tahan UV, putar setiap 3 bulan untuk mencegah deformasi.
TENTANG KAMI
GUDANG KAMI
MENGAPA KAMI
MITRA

Peringkat Keseluruhan
5 BINTANG
100%
Bintang 4
0
3 Bintang
0
Bintang 2
0
1 bintang
0
Semua Ulasan
-
Afast delivery and good quality, so as the service