logo
Found 379 products for "

xlpe insulated cable

"
Quality ASTM Standard Aerial Bundled ABC Power Cable 15kV 35kV For Overhead Distribution Line factory

ASTM Standard Aerial Bundled ABC Power Cable 15kV 35kV For Overhead Distribution Line

ASTM Standard Aerial Bundled ABC Power Cable 15kV 35kV For Overhead Distribution Line APPLICATION Screened MV ABC cables are specialized power transmission solutions combining medium-voltage (MV) capabilities with the structural advantages of Aerial Bunch Cables (ABC). Their applications include: Medium-Voltage Distribution Networks Aerial Power Infrastructure Industrial Power Supply Renewable Energy Projects CONSTRUCTION Conductor: Circular Compacted Stranded H68

Quality 11KV 22KV 33KV Medium Voltage Cable XLPE/Vinyl/Cu 3 Core factory

11KV 22KV 33KV Medium Voltage Cable XLPE/Vinyl/Cu 3 Core

11KV 22KV 33KV Medium Voltage Cable XLPE/Vinyl/Cu 3 Core Application 1. Industrial power distribution: factory power supply, mining and petrochemical industry2. Construction and infrastructure: commercial buildings, subways and tunnels3. Energy and power transmission: substation connection, new energy projects4. Underground and submarine laying: underground cable engineering, submarine cable Construction Conductor: Circular compacted stranded Copper or aluminium Conductor

Quality 6kV to 35kV 3-Core MV Power Cable, Armored Medium Voltage Cable factory

6kV to 35kV 3-Core MV Power Cable, Armored Medium Voltage Cable

6kV to 35kV 3-Core MV Power Cable, Armored Medium Voltage Cable APPLICATION Medium voltage 3-core cables (typically rated from 6 kV to 36 kV) are widely used in power distribution networks due to their balanced phase loading, compact design, and enhanced reliability compared to single-core alternatives. Urban & Industrial Distribution:Deployed in substations, factories, and commercial complexes to transmit power with reduced electromagnetic interference (EMI). Preferred for

Quality EAC Certified Fire Resistant Cable N2XH LSZH Environmental Protection Cable factory

EAC Certified Fire Resistant Cable N2XH LSZH Environmental Protection Cable

EAC Certified Fire Resistant Cable N2XH LSZH Environmental Protection Cable APPLICATION & CHARACTERISTICS Petrochemical processing units (reactor jackets, distillation columns) Steel mill conveyor systems (blast furnace zones, rolling mills) Aerospace engine compartment wiring CONSTRUCTION Conductor: Typically composed of high-purity copper or aluminum, annealed for flexibility and low resistance. Insulation: Cross-linked polyethylene (XLPE) insulation provides excellent

Quality Underground Medium Voltage 11kv 15kv 22kv 70mm-400 Sqmm Aluminium Armoured Power Cable factory

Underground Medium Voltage 11kv 15kv 22kv 70mm-400 Sqmm Aluminium Armoured Power Cable

Underground Medium Voltage 11kv 15kv 22kv 70mm-400 Sqmm Aluminium Armoured Power Cable Application The cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 1KV to 35KV and frequency 50Hz, as in power supply stations, indoors and in cable ducts, outdoors, underground. Construction Conductor: Class 2 Aluminium conductor Conductor: Semi-conductive shield Insulation: Cross-Linked Polyethylene(XLPE) Insulation shield: Semi-conductive

Quality CU XLPE LC PVC 110kV High Voltage Cable Copper Wire Shielded Cable for Underground factory

CU XLPE LC PVC 110kV High Voltage Cable Copper Wire Shielded Cable for Underground

CU/XLPE/LC/PVC 110kV High Voltage Cable Copper Wire Shielded Cable Application Power station connections: Transmitting electricity from generators to substations or directly integrating into grid systems, Suitable for underground installations in complex terrains (e.g., mountainous regions) to ensure stable power delivery Urban power networks: Deployed in densely populated areas where overhead lines are impractical, minimizing spatial occupation and enhancing safety

Quality Copper Tape Shield Medium Voltage Armored Cable 6KV 10kV 600sq Underground Use factory

Copper Tape Shield Medium Voltage Armored Cable 6KV 10kV 600sq Underground Use

Copper Tape Shield Medium Voltage 6/10kV Steel Tape Armoured 600sq Underground Use Construction Conductor: Circular compacted stranded Copper or aluminium Conductor screen: Extruded semi-conductive compound Insulation: XLPE Insulation screen: Extruded semi-conductive compound Metallic screen: Copper Wire Binder tape: non-hygroscopic material Inner covering(bedding): PVC Metallic armor: Galvanized steel tape Application Suitable for urban underground power grids, power station

Quality Medium Voltage Aerial Bundled Cable ABC Cable 6.35/11kV Screened MV ABC Cable to IEC 60502 factory

Medium Voltage Aerial Bundled Cable ABC Cable 6.35/11kV Screened MV ABC Cable to IEC 60502

Medium Voltage Aerial Bundled Cable ABC Cable 6.35/11kV Screened MV ABC Cable to IEC 60502 APPLICATION Three XLPE insulated screened cores are bundled around the galvanized steel wires in a right hand lay.Primarily used for overhead service applications such as street lighting,outdoor lighting,and temporary service for construction. To be used at vo l tages of 600V phase-to-phase or less and at conductor temperatures not to exceed 75 for polyethylence insulated conductors or

Quality 630mm2 High Voltage Cable 110kV  Electric Single Core Copper Water Proof Resistant Power factory

630mm2 High Voltage Cable 110kV Electric Single Core Copper Water Proof Resistant Power

630mm2 High Voltage Cable 110kV Electric Single Core Copper Water Proof Resistant Power APPLICATION For laying indoors,in tunnel cable trench,well or direct in ground,able to bear external mechanical forces and certain pulling force. CONSTRUCTION High Voltage: Designed for power distribution and construction applications. XLPE Insulation: Provides superior electrical insulation and durability. Copper Conductor: Ensures reliable and efficient power transmission. Wide Range of