xlpe insulated cable
"
Cables de acero blindados resistentes al fuego 0.6 1.0kV Dos núcleos de cable eléctrico a prueba de calor
Steel Wire Armoured Fire Resistant Cable 0.6/1.0kV Two Core Application Fire resistant cables can be used in several critical buildings where safety against fire is mandatory to reduce the risk of death as: Hospitals & Old people’shomes. Schools & Recreational buildings. Museums & Historical places. Undergrounds & Tunnels. Railways & Airports. Shopping Centers & Malls. Theatres & Cinemas. Hotels & Offices. High-rise buildings Construction Conductor: Plain Annealed
Cables de energía de voltaje medio con 3 núcleos de protección con conductores en cadena revestidos de PVC
3 core Screened Medium Voltage Cable with PVC Sheathed Stranded Conductors Application Medium voltage power cable for static application in ground, within and outside facilities, outdoor, in cable canals,in water, in conditions where cables are not exposed to heavier mechanical stress and tensile strain. Construction Stranded compacted conductor, triple extruded conductor screen, insulation and insulation screen, copper wire screened, laid-up, PVC bedded, steel wire armoured,
Cable resistente al fuego 450V 750V Cable flexible con calificación de incendio
CE Certification Fire Resistant Cable Flexible Cable/Rated voltage 450/750V Application For system connection wire of control, signal, protection or measuring with rated voltage up to and including 450/750KV. Construction Conductor: Plain annealed copper (class 2, normal stranded or compact stranded) Fire barrier: Mica tape Insulation: XLPE Filler, binder and inner covering: PP, PET, LSZH Outer sheath: LSZH Technical parameters Single Core Cross section of conductor(mm²)
Cables de seguridad contra incendios de voltaje medio con conductores en cadena revestidos de PVC
Medium Voltage Fire Resistant Cable with PVC Sheathed Stranded Conductors Application Fire resistant cables can be used in several critical buildings where safety against fire is mandatory to reduce the risk of death as: Hospitals & Old people’shomes. Schools & Recreational buildings. Museums & Historical places. Undergrounds & Tunnels. Railways & Airports. Shopping Centers & Malls. Theatres & Cinemas. Hotels & Offices. High-rise buildings Construction Stranded co
Cables resistentes al fuego de baja humedad y sin halógenos LSZH Cables de fibra de vidrio trenzados de alambre longitud personalizada
Low Smoke Zero Halogen Fire Resistant Cable Fiberglass Braid Wire Application Fire-resistant cables are designed to maintain circuit integrity and continue operating during fire emergencies, ensuring critical systems remain functional. These cables are essential in environments where fire safety and uninterrupted power supply are priorities Construction Conductor: Plain annealed copper (class 2, normal stranded or compact stranded) Fire barrier: Mica tape Insulation: XLPE
450/750 Fire Resistant Control Cable CU/PVC/STW/PVC NYY NYBY 2-61 Cores
450/750 Fire Resistant Control Cable CU/PVC/STW/PVC NYY NYBY 2-61 Cores APPLICATION This product is suitable for use in control, monitoring circuits, and protection circuits in circuits with a rated voltage of 450/750V and below CONSTRUCTION Conductor C ircular solid copper conductor (A) or circular stranded copper conductor (B) Insulation Polyvinyl chloride (PVC) Filler Polypropylene (PP) m esh f illing r ope Armouring (optional) Galvanized steel tape Outer sheath Polyvinyl
Cables solares de cobre enlatados XLPO Envase PV H1Z2Z2-K 4mm 6mm 10mm Resistente a las intemperie
Tinned Copper Solar Cable XLPO Sheath PV H1Z2Z2-K 4mm 6mm 10mm Product Presentation H1Z2Z2-K is a harmonized cable type that complies with European standards (e.g., EN 50618). It is specifically designed for use in photovoltaic systems, connecting solar panels, inverters, and other components of a PV installation. The "K" in the name indicates that the cable has a tinned copper conductor, which provides better corrosion resistance. Structure Conductor: Tinned copper, offering
IEC 60502 STA Cable eléctrico blindado de tres núcleos para uso subterráneo
IEC 60502 STA Armoured Electrical Cable Three Core for underground use Application PVC power cable for static outdoor application (with protection against direct UV-irradiation), in ground, in water, within facilities, in cable canals, in concrete, in conditions where heavier mechanical loads and specially tensile strains, are not expected. Used in electric power plants, transformer stations, industrial plants, metropolitan networks and in other electric plants, same as for
Cable MV ABC de alto rendimiento 12.7/22kv 3x150+50 mm para líneas aéreas
High Performance MV ABC Cable 12.7/22kv 3x150+50mm for Overhead Power Lines Deatils Phase Conductor : Aluminium Conductor Neutral Conductor : AAC/AAAC/ACSR Insulation : XLPE/PE Rated Voltage : 1-35KV Cores : 1,3 Cores Construction Specification UMBER OF CORES X NOMINAL CROSS SECTION PHASE CONDUCTOR MESSENGER SUSPENSION UNIT CONTINUOUS CURRENT RATING AT 300C AMBIENT TEMP STRANDING NOMINAL SECTIONAL AREA MAXIMUM CONDUCTOR RESISTANCE STRANDING NOMINAL SECTIONAL AREA BREAKING