| Insulation Material: | XLPE | Screen: | Copper Wire |
|---|---|---|---|
| Rated Voltage: | 21/35kV | No Of Core: | 3 |
| Conductor: | Copper Or Alumnium | Jacket: | PVC |
STA Armored MV Power Cable 8.7/15kV Single Core XLPE PVC for Construction Overhead Underground Power Stations
These cables have the advantage of simplicity in construction, lightness in weight; onvenience in application besides its excellent electrical, thermal, mechanical and anti-chemical corrosion properties. It can also be laid with no limitation of level difference along the route.
Conductor: Tightly press round conductor
Conductor Screen:Semi-conductive shield
Insulation:XLPE
Insulation shield:Semi-conductive shield
Metal shielding layer:Copper tape: Copper Wire:35kV above 500mm2
Binder tape:Non-woven fabrics
Isolation sleeve:Polyvinyl chloride(PVC)
Armour:Non-magnetic steel wire
Outer sheath:Polyvinyl chloride (PVC)
Voltage Rating Uo/U(UM)
3.6/6(7.2)kV 6/6(7.2)kV 6/10(12)kV 8.7/10(12)kV 8.7/15(17.5)kV 12/20(24)kV
18/20(24)kV 18/30(36kV ) 21/35(40.5)kV 26/35(40.5)kV
Maximum operating temperature of conductor:+90℃
Operating ambient temperature: -15℃~+55℃
Cable laying temperature:Not less than 0℃(When the ambient temperature is below 0℃, the cable should be preheated.)
Minimum Bending Radius
Single core:15D
Multicire: 12D
(D is the actual outer diameter of the cable)
|
Specs mm² |
Conductor diameter mm |
Nominal thickness of insulation ±1.0mm |
Approx outer diameter of cable mm |
Approx cable weight kg/km |
|
Specs mm² |
Conductor diameter mm |
Nominal thickness of insulation ±1.0mm |
Approx outer diameter of cable mm |
Approx cable weight kg/km |
|
1×50 |
7.6±0.2 |
312 |
43.5 |
3713 |
|
3x50 |
3x50 |
3x50 |
3x50 |
3x50 |
|
1×70 |
9.2±0.2 |
32.8 |
45.2 |
4091 |
|
3x70 |
3x70 |
3x70 |
3x70 |
3x70 |
|
1×95 |
10.9±0.2 |
34.5 |
46.9 |
4499 |
|
3x95 |
3x95 |
3x95 |
3x95 |
3x95 |
|
1×120 |
12.2±0.2 |
35.8 |
48.4 |
4893 |
|
3x120 |
3x120 |
3x120 |
3x120 |
3x120 |
|
1×150 |
13.6±0.2 |
372 |
50.1 |
5317 |
|
3x150 |
3x150 |
3x150 |
3x150 |
3x150 |
|
1×185 |
15.2±0.2 |
38.8 |
51.7 |
5798 |
|
3x185 |
3x185 |
3x185 |
3x185 |
3x185 |
|
1×240 |
17.4±0.2 |
41.0 |
53.9 |
6544 |
|
3x240 |
3x240 |
3x240 |
3x240 |
3x240 |
|
1×300 |
19.5±0.2 |
43.1 |
56.4 |
7375 |
|
3x300 |
3x300 |
3x300 |
3x300 |
3x300 |
|
1×400 |
22.0±0.2 |
45.6 |
59.2 |
8392 |
|
3x400 |
3x400 |
3x400 |
3x400 |
3x400 |
|
1×500/35 |
24.8±0.2 |
492 |
65.4 |
10198 |
|
3x500/35 |
3x500/35 |
3x500/35 |
3x500/35 |
3x500/35 |
|
1×630/35 |
28.2±0.2 |
52.6 |
69.1 |
11876 |
|
3x630/35 |
3x630/35 |
3x630/35 |
3x630/35 |
3x630/35 |
|
1×800/35 |
34.0±0.2 |
58.4 |
76.9 |
15153 |
|
|
|
|
|
|
This table shows 21/36kv data, for more voltage, please contact us for details
![]()
![]()
![]()
![]()
![]()