cabo da baixa tensão
Cabo de Borracha H07RN-F | Cabo de Alimentação Flexível de Alta Resistência 450/750V
H07RN-F Rubber Cable | Heavy-Duty Flexible Power Cable 450/750V Product Overview The H07RN-F rubber cable is a heavy-duty flexible power cable designed for demanding industrial and outdoor applications. Recognized across Europe and internationally, this HAR-approved cable features a Class 5 flexible copper conductor, EPR (Ethylene Propylene Rubber) insulation, and a tough PCP (Polychloroprene) rubber outer sheath . Rated at 450/750V, the H07RN-F cable is engineered to
NA2XY – YJLV (AL/XLPE/PVC) Monopolar 0.6/1kV – Cabo de Alimentação de Alumínio para Distribuição de Baixa Tensão
A2XY – YJLV (AL/XLPE/PVC) Single Core 0.6/1kV – Aluminum Power Cable for Low Voltage Distribution Product Overview The NA2XY – YJLV (AL/XLPE/PVC) Single Core 0.6/1kV is a high-performance low voltage power cable designed for reliable and cost-effective electricity distribution in 0.6/1kV systems. This cable features an aluminum conductor, XLPE (cross-linked polyethylene) insulation, and a PVC outer sheath. Offering an excellent balance between cost efficiency and electrical
Cabo de Alimentação PE de 4 Núcleos, Núcleo de Cobre, Isolamento XLPE, N2X2Y, Norma IEC60852-1
4 Core PE Power Cable Cu Core XLPE Insulated N2X2Y IEC60852-1 Standard APPLICATION PE Power cables are used for low-voltage power distribution (0.6/1 kV) in fixed installations, suitable for indoor and outdoor laying including cable trays, ducts, and conduits, and used in supplying buildings, industrial equipment, and general electrical loads. CONSTRUCTION Type: N2X2Y Conductor: Copper (Cu) Insulation: Cross-Linked Polyethylene (XLPE) Sheath: PE CHARACTERISTIC Rated voltage:
Cabos industriais RV-K padrão espanhol Cabos Powerflex UNE 21123-2
Spanish Standard RV-K Industrial Cables Powerflex Cable UNE 21123-2 APPLICATION RV-K cable is a low-voltage flexible copper conductor cable commonly used for power distribution and internal wiring in residential, commercial, and industrial installations. It is designed for rated voltages of 0.6/1 kV and is widely used in environments requiring flexible, easy-to-install wiring. CONSTRUCTION Flexible plain copper strands: Strands to VDE-0295 Class-5, IEC 60228 Class-5 XLPE
N2XC2Y IEC60502 LV Cable Conductor de cobre XLPE Isolamento PE Cabo de alimentação da bainha
N2XC2Y IEC60502 LV Cable Copper Conductor XLPE Insulation PE Sheath Power Cable APPLICATION For outdoor installation, in the ground, for power stations, industry and distribution boards or subscriber networks, where protection against contact voltage is required in the case of mechanical damage. The core insulation of XLPE allows a higher operating temperature than comparable cable with PVC core insulation. The cables are halogen-free, UV-resistant and particularly resistant
Cabos de baixa tensão de alto desempenho 3 núcleos 4 núcleos 5 núcleos CU/XLPE/PVC
High Performance Low Voltage Cable 3 Core 4 Core 5 Core CU/XLPE/PVC Cable APPLICATION The cables are typically used in 0.6/1kV rated voltage circuits , the main applications include p ower transmission and distribution , Industrial Equipment and commercial building, and underground Distribution and harsh area etc. CONSTRUCTION Conductor: Class 2 stranded Copper conductor Insulation: Cross-Linked Polyethylene(XLPE) Outer sheath: Polyvinyl chloride (PVC) CHARACTERISTIC Voltage
Multi Core Cu Condutor Cabos de baixa tensão Armadura de arame de aço LV Cabos de alimentação
0.6/1kV Cu Conductor XLPE Insulation Low Voltage Cable Steel Wire Armour Power Cable APPLICATION The cables are used in power networks, underground, outdoor, indoor and cable ducting where fire, smoke emission and toxic fumes create a potential threat to life and equipment . DESIGN & CONSTRUCTION CONDUCTOR:Circular, solid, compacted or sector shaped stranded Copper or aluminu Insulation : XLPE Filler :Non-hygroscopic material Inner sheath:PVC Armour :Steel Wire Armoured
Cable de baixa tensão de cobre negro XLPE isolado PVC revestido Logotipo personalizado
YJV Copper Conductor Low Voltage Cable XLPE Insulated PVC Sheathed Application These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage. Construction 1. Conductor: Copper/Aluminum/Aluminum Alloy 2. Insulation: Cross-linked polyethylene XLPE 3
0.6KV 1KV XLPE Cabos LV de baixa tensão isolados com condutor de cobre LSZH revestido
0.6/1kV XLPE Insulated Low Voltage Cable Copper Conductor LSZH Sheathed Application The cables are mainly used in power networks, underground, outdoor, and indoor applications, as well as cable ducting where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Construction Conductor: Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228. Insulation: Cross-linked polyethylene (XLPE) Inner covering:PVC Outer sheath: PVC outer
Cabo de alimentação de baixa tensão 0,6/1kV VVg VVgng com certificação EAC, cabo retardador de chama
EAC Certificated 0.6/1kV Low voltage Power Cable VVg VVgng Flame-retardant Cable APPLICATION The cable is designed for fixed electrical installations in industrial and nuclear power plants, ensuring safe energy transmission under AC voltage (0.66/1/3 kV, 50 Hz) or DC voltage (1/1.5/4.5 kV). CONSTRUCTION Conductor: Class 1/ Class 2 stranded Copper conductor Insulation: Polyvinyl chloride (PVC) Filler ( options ): Polypropylene mesh tearing rope Outer sheath: Polyvinyl
N2XBY NA2XBY 3 núcleo cabo de baixa tensão 0,6 / 1kV 0,5 ~ 800MM2 1V cabo
N2XBY NA2XBY Low Voltage Cable 3 Core 0.6/1kV 0.5 ~ 800MM2 Construction Conductor: Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation: XLPE Filler: non-hygroscopic material Binder tape: non-hygroscopic material Sheath: PVC Characteristics Test Voltage: 3.5kV 5min No Breakdown The ambient temperature for installation: ≥0℃. Maximum conductor temperature in normal operation:≤90℃. Max operating temperature of con. When cable short-circuited(5s
Cabo de baixa tensão Cabo de alimentação de alumínio não blindado NA2XY de núcleo único
Low Voltage Cable Non-Armoured Aluminum Power Cable NA2XY Single Core APPLICATION NA2XY cables are widely used in low voltage power distribution and electrical systems across multiple industries. The key applications include: Building and Construction, Industrial Facilities, Infrastructure, utilities and s pecial environments etc. CONSTRUCTION 1. Conductor: Compact aluminium 1350, class 2. 2. Insulation: Cross linked polyethylene XLPE. 3. Outer sheath: Polyvinyl chloride PVC
Cabo elétrico de baixa tensão com logotipo personalizado, retardante de chama, 3 núcleos, 0,6/1kV, CU/XLPE/STA/PVC, cabo industrial
Flame Retardant Low Voltage Cable 3 Core 0.6/1kV CU/XLPE/ STA/PVC Industrial Cable APPLICATION This custom logo 3-core low-voltage industrial cable, rated at 0.6/1kV with a CU/XLPE/STA/PVC structure and flame-retardant performance, is engineered for reliable power transmission and distribution in various industrial scenarios, with the custom logo enabling easy brand identification and product traceability CONSTRUCTION Conductor: Class 1 or class 2 stranded Copper conductor
Cabo de baixa tensão não blindado 0,6/1kV Conductor de cobre XLPE Isolamento PE revestido Cabo de alimentação resistente ao fogo
Non Armoured Low Voltage Cable 0.6/1kV Copper Conductor XLPE Insulation PE Sheathed Fire-resistant Power Cable Application Application of Non Armoured Low Voltage Cable 0.6/1kV Copper Conductor XLPE Insulation PE Sheathed Fire-resistant Power Cable This cable is widely used in industrial and commercial buildings where fire safety is critical. It is commonly installed in power distribution systems, emergency lighting circuits, and fire alarm systems. Due to its flame
Cable blindado LV resistente ao fogo 0,6/1kV CU/XLPE/STA/PVC Retardante de chama Classe C
Fire Resistant LV Armoured Cable 0.6/1kV CU/XLPE/STA/PVC Flame retardant Class C power cable Application This cable is widely used in industrial and commercial buildings where fire safety is critical. It is commonly installed in power distribution systems, emergency lighting circuits, and fire alarm systems. Due to its flame-retardant properties and steel tape armour, it is suitable for underground installations, tunnels, and areas with high mechanical stress.
Cabo de alimentação de baixa tensão 0,6/1kV de três condutores 1,5mm2 a 400mm2 Cabo certificado EAC
Three Core 0.6/1kV Low voltage Power Cable 1.5mm2 to 400mm2 EAC Certified Cable APPLICATION Three Core 0.6/1kV Low Voltage Power Cable with EAC certification is designed for: Underground installations in commercial/residential power distribution systems, utilizing durable PVC/XLPE insulation for environmental protection Industrial applications such as construction sites and power stations, where armored variants (e.g., SWA) provide mechanical strength Low-voltage networks
Cabo de Baixa Tensão Retardante de Chama 4 Condutores 0,6/1kV CU/XLPE/ STA/PVC Cabo Industrial
Flame Retardant Low Voltage Cable 4 Core 0.6/1kV CU/XLPE/ STA/PVC Industrial Cable APPLICATION This product is suitable for use in circuits with a rated voltage not exceeding 0.6/1kV, for the purpose of power transmission and distribution. CONSTRUCTION Conductor: Class 1 or class 2 stranded Copper conductor Insulation: Cross-Linked Polyethylene(XLPE) Inner sheath: Polyvinyl chloride (PVC) Armour: Single core: Steel Tape Multi core: Galvanized Steel Tape Outer sheath:
Cabo de baixa tensão resistente ao fogo com 3 condutores e LSZH para distribuição de energia subterrânea
Fire Rated Low Voltage Wire N2XY with 3 Core 1.5-400mm² Underground Power Cable Product Overview Fire Rated Low Voltage Wire with 3 Core 1.5-400mm² is engineered to maintain circuit integrity during fire conditions, ensuring continuous power supply for critical emergency systems. Applications This fire-resistant cable is specifically designed for critical systems including emergency lighting, fire alarms, and evacuation systems. Its three-core configuration (phase, neutral,
Cabo de Baixa Tensão LSZH com Condutor de Cobre e Isolamento XLPE para Infraestrutura Industrial e Pública
LSZH Low Voltage STA Low Smoke Zero Halogen Cable N2X2Y Applications Industrial Machinery Public Infrastructure Renewable Energy Systems Underground or Duct Installation Temporary Power Supply Fire-Sensitive Areas Construction Conductor: Class 1/Class 2 stranded Copper conductor Refractory layer: Single sided gold mica tape Insulation: XLPE Filler (options): Polypropylene mesh tear rope or flame-retardant filling Outer sheath: LOSH Characteristics Voltage Rating: Uo/U: 0.6