cavo di bassa tensione
Cavo in gomma H07RN-F | Cavo di alimentazione flessibile per impieghi gravosi 450/750V
H07RN-F Rubber Cable | Heavy-Duty Flexible Power Cable 450/750V Product Overview The H07RN-F rubber cable is a heavy-duty flexible power cable designed for demanding industrial and outdoor applications. Recognized across Europe and internationally, this HAR-approved cable features a Class 5 flexible copper conductor, EPR (Ethylene Propylene Rubber) insulation, and a tough PCP (Polychloroprene) rubber outer sheath . Rated at 450/750V, the H07RN-F cable is engineered to
NA2XY – YJLV (AL/XLPE/PVC) Monopolare 0.6/1kV – Cavo di Alimentazione in Alluminio per Distribuzione a Bassa Tensione
A2XY – YJLV (AL/XLPE/PVC) Single Core 0.6/1kV – Aluminum Power Cable for Low Voltage Distribution Product Overview The NA2XY – YJLV (AL/XLPE/PVC) Single Core 0.6/1kV is a high-performance low voltage power cable designed for reliable and cost-effective electricity distribution in 0.6/1kV systems. This cable features an aluminum conductor, XLPE (cross-linked polyethylene) insulation, and a PVC outer sheath. Offering an excellent balance between cost efficiency and electrical
Cable di alimentazione in PE a 4 nuclei Cu Core XLPE Isolato N2X2Y Standard IEC60852-1
4 Core PE Power Cable Cu Core XLPE Insulated N2X2Y IEC60852-1 Standard APPLICATION PE Power cables are used for low-voltage power distribution (0.6/1 kV) in fixed installations, suitable for indoor and outdoor laying including cable trays, ducts, and conduits, and used in supplying buildings, industrial equipment, and general electrical loads. CONSTRUCTION Type: N2X2Y Conductor: Copper (Cu) Insulation: Cross-Linked Polyethylene (XLPE) Sheath: PE CHARACTERISTIC Rated voltage:
Cavi Industriali Standard RV-K Powerflex UNE 21123-2
Spanish Standard RV-K Industrial Cables Powerflex Cable UNE 21123-2 APPLICATION RV-K cable is a low-voltage flexible copper conductor cable commonly used for power distribution and internal wiring in residential, commercial, and industrial installations. It is designed for rated voltages of 0.6/1 kV and is widely used in environments requiring flexible, easy-to-install wiring. CONSTRUCTION Flexible plain copper strands: Strands to VDE-0295 Class-5, IEC 60228 Class-5 XLPE
N2XC2Y IEC60502 LV Cable Copper Conductor XLPE Isolation PE Sheath Power Cable
N2XC2Y IEC60502 LV Cable Copper Conductor XLPE Insulation PE Sheath Power Cable APPLICATION For outdoor installation, in the ground, for power stations, industry and distribution boards or subscriber networks, where protection against contact voltage is required in the case of mechanical damage. The core insulation of XLPE allows a higher operating temperature than comparable cable with PVC core insulation. The cables are halogen-free, UV-resistant and particularly resistant
Cavo a bassa tensione ad alte prestazioni 3 conduttori 4 conduttori 5 conduttori CU/XLPE/PVC
High Performance Low Voltage Cable 3 Core 4 Core 5 Core CU/XLPE/PVC Cable APPLICATION The cables are typically used in 0.6/1kV rated voltage circuits , the main applications include p ower transmission and distribution , Industrial Equipment and commercial building, and underground Distribution and harsh area etc. CONSTRUCTION Conductor: Class 2 stranded Copper conductor Insulation: Cross-Linked Polyethylene(XLPE) Outer sheath: Polyvinyl chloride (PVC) CHARACTERISTIC Voltage
Cable a bassa tensione a cuota multi-core Cable a bassa tensione a filo di acciaio Armatura LV
0.6/1kV Cu Conductor XLPE Insulation Low Voltage Cable Steel Wire Armour Power Cable APPLICATION The cables are used in power networks, underground, outdoor, indoor and cable ducting where fire, smoke emission and toxic fumes create a potential threat to life and equipment . DESIGN & CONSTRUCTION CONDUCTOR:Circular, solid, compacted or sector shaped stranded Copper or aluminu Insulation : XLPE Filler :Non-hygroscopic material Inner sheath:PVC Armour :Steel Wire Armoured
Cable a bassa tensione in rame nero XLPE Isolato in PVC con involucro Logo personalizzato
YJV Copper Conductor Low Voltage Cable XLPE Insulated PVC Sheathed Application These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage. Construction 1. Conductor: Copper/Aluminum/Aluminum Alloy 2. Insulation: Cross-linked polyethylene XLPE 3
0.6KV 1KV XLPE Cablo LV a bassa tensione isolato con conduttore di rame LSZH avvolto
0.6/1kV XLPE Insulated Low Voltage Cable Copper Conductor LSZH Sheathed Application The cables are mainly used in power networks, underground, outdoor, and indoor applications, as well as cable ducting where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Construction Conductor: Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228. Insulation: Cross-linked polyethylene (XLPE) Inner covering:PVC Outer sheath: PVC outer
EAC Certificato 0.6/1kV Cavo di alimentazione a bassa tensione VVg VVgng Cavo ignifugio
EAC Certificated 0.6/1kV Low voltage Power Cable VVg VVgng Flame-retardant Cable APPLICATION The cable is designed for fixed electrical installations in industrial and nuclear power plants, ensuring safe energy transmission under AC voltage (0.66/1/3 kV, 50 Hz) or DC voltage (1/1.5/4.5 kV). CONSTRUCTION Conductor: Class 1/ Class 2 stranded Copper conductor Insulation: Polyvinyl chloride (PVC) Filler ( options ): Polypropylene mesh tearing rope Outer sheath: Polyvinyl
N2XBY NA2XBY 3 Core Cavo a bassa tensione 0.6/1kV 0.5~800MM2 1V
N2XBY NA2XBY Low Voltage Cable 3 Core 0.6/1kV 0.5 ~ 800MM2 Construction Conductor: Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation: XLPE Filler: non-hygroscopic material Binder tape: non-hygroscopic material Sheath: PVC Characteristics Test Voltage: 3.5kV 5min No Breakdown The ambient temperature for installation: ≥0℃. Maximum conductor temperature in normal operation:≤90℃. Max operating temperature of con. When cable short-circuited(5s
Cavo a bassa tensione Cavo di alimentazione in alluminio non blindato NA2XY a singolo nucleo
Low Voltage Cable Non-Armoured Aluminum Power Cable NA2XY Single Core APPLICATION NA2XY cables are widely used in low voltage power distribution and electrical systems across multiple industries. The key applications include: Building and Construction, Industrial Facilities, Infrastructure, utilities and s pecial environments etc. CONSTRUCTION 1. Conductor: Compact aluminium 1350, class 2. 2. Insulation: Cross linked polyethylene XLPE. 3. Outer sheath: Polyvinyl chloride PVC
Cavo elettrico a bassa tensione con logo personalizzato, ignifugo, a 3 conduttori, 0.6/1kV CU/XLPE/STA/PVC, per uso industriale
Flame Retardant Low Voltage Cable 3 Core 0.6/1kV CU/XLPE/ STA/PVC Industrial Cable APPLICATION This custom logo 3-core low-voltage industrial cable, rated at 0.6/1kV with a CU/XLPE/STA/PVC structure and flame-retardant performance, is engineered for reliable power transmission and distribution in various industrial scenarios, with the custom logo enabling easy brand identification and product traceability CONSTRUCTION Conductor: Class 1 or class 2 stranded Copper conductor
Cavo a bassa tensione non blindato 0,6/1kV Conductor di rame XLPE Isolamento PE Involucro Cavo di alimentazione resistente al fuoco
Non Armoured Low Voltage Cable 0.6/1kV Copper Conductor XLPE Insulation PE Sheathed Fire-resistant Power Cable Application Application of Non Armoured Low Voltage Cable 0.6/1kV Copper Conductor XLPE Insulation PE Sheathed Fire-resistant Power Cable This cable is widely used in industrial and commercial buildings where fire safety is critical. It is commonly installed in power distribution systems, emergency lighting circuits, and fire alarm systems. Due to its flame
Cavo armato a bassa tensione resistente al fuoco 0.6/1kV CU/XLPE/STA/PVC Cavo di alimentazione ritardante di fiamma Classe C
Fire Resistant LV Armoured Cable 0.6/1kV CU/XLPE/STA/PVC Flame retardant Class C power cable Application This cable is widely used in industrial and commercial buildings where fire safety is critical. It is commonly installed in power distribution systems, emergency lighting circuits, and fire alarm systems. Due to its flame-retardant properties and steel tape armour, it is suitable for underground installations, tunnels, and areas with high mechanical stress.
Cavo di alimentazione a bassa tensione 0.6/1kV a tre conduttori da 1.5mm2 a 400mm2 Certificato EAC
Three Core 0.6/1kV Low voltage Power Cable 1.5mm2 to 400mm2 EAC Certified Cable APPLICATION Three Core 0.6/1kV Low Voltage Power Cable with EAC certification is designed for: Underground installations in commercial/residential power distribution systems, utilizing durable PVC/XLPE insulation for environmental protection Industrial applications such as construction sites and power stations, where armored variants (e.g., SWA) provide mechanical strength Low-voltage networks
Cavo a bassa tensione ignifugo 4 core 0,6/1kV CU/XLPE/ STA/PVC
Flame Retardant Low Voltage Cable 4 Core 0.6/1kV CU/XLPE/ STA/PVC Industrial Cable APPLICATION This product is suitable for use in circuits with a rated voltage not exceeding 0.6/1kV, for the purpose of power transmission and distribution. CONSTRUCTION Conductor: Class 1 or class 2 stranded Copper conductor Insulation: Cross-Linked Polyethylene(XLPE) Inner sheath: Polyvinyl chloride (PVC) Armour: Single core: Steel Tape Multi core: Galvanized Steel Tape Outer sheath:
Cavo a bassa tensione a fuoco con 3 nuclei e LSZH per la distribuzione di energia sotterranea
Fire Rated Low Voltage Wire N2XY with 3 Core 1.5-400mm² Underground Power Cable Product Overview Fire Rated Low Voltage Wire with 3 Core 1.5-400mm² is engineered to maintain circuit integrity during fire conditions, ensuring continuous power supply for critical emergency systems. Applications This fire-resistant cable is specifically designed for critical systems including emergency lighting, fire alarms, and evacuation systems. Its three-core configuration (phase, neutral,
Cavo a bassa tensione LSZH con conduttore di rame e isolamento XLPE per infrastrutture industriali e pubbliche
LSZH Low Voltage STA Low Smoke Zero Halogen Cable N2X2Y Applications Industrial Machinery Public Infrastructure Renewable Energy Systems Underground or Duct Installation Temporary Power Supply Fire-Sensitive Areas Construction Conductor: Class 1/Class 2 stranded Copper conductor Refractory layer: Single sided gold mica tape Insulation: XLPE Filler (options): Polypropylene mesh tear rope or flame-retardant filling Outer sheath: LOSH Characteristics Voltage Rating: Uo/U: 0.6