Informação Básica
Lugar de origem: Hebei,China
Marca: PVC Insulated Power Cable
Certificação: IEC,CE,ISO,TUV
Número do modelo: NYY VV
Quantidade de ordem mínima: Negociável
Preço: Negociável
Detalhes da embalagem: Rolinhos, tambores de madeira, tambores de aço, rolos ou personalizados
Tempo de entrega: 7-30 dias com base em diferentes quantidades
Termos de pagamento: L/C,T/T
Habilidade da fonte: 100km/semana
Informação detalhada
Tensão: 0.6/ 1 kV Blindagem: Não
Isolamento: PVC Essencial: Múltiplos Núcleos
Faixa de temperatura: - 30°C a + 70°C Embainhado: PVC

Descrição de produto

0.6/1kV Copper Conductor PVC Insulation PVC Sheathed Power Cable – Low Voltage General Purpose Power Cable


Product Overview

The 0.6/1kV Copper Conductor PVC Insulation PVC Sheathed Power Cable – commonly referred to as NYY cable (European designation) or VV cable (Chinese designation) – is a versatile, reliable, and cost-effective low voltage power cable designed for fixed installation in industrial, commercial, and residential applications.

This cable features a copper conductor for excellent conductivity, PVC insulation for reliable electrical isolation, and a PVC outer sheath for mechanical and environmental protection. Rated at 0.6/1kV, it is suitable for most low voltage power distribution needs, from main feeder lines to branch circuits.

European designation: NYY
Chinese designation: VV
Voltage rating: 0.6/1kV (U₀/U)
Conductor material: Copper (Class 1 or Class 2)
Insulation: PVC (Polyvinyl Chloride) – Type TI
Sheath: PVC (Polyvinyl Chloride) – Type TM
Standards: IEC 60502-1, GB/T 12706, BS 6346, VDE 0276

Key Features



Feature Benefit
Copper conductor Excellent electrical conductivity (100% IACS), reliable performance
PVC insulation Good dielectric properties, moisture resistant, economical
PVC outer sheath Provides mechanical protection, UV resistance (black version), and moisture barrier
0.6/1kV rating Suitable for most low voltage power distribution applications
Wide size range Available from 1.5mm² up to 630mm² in multi-core configurations
Fixed installation Designed for permanent installation in dry or damp environments
Industry standard Compliant with international and national standards
Flame retardant PVC materials are inherently flame retardant

Applications

The 0.6/1kV Copper Conductor PVC Insulation PVC Sheathed Power Cable (NYY / VV) is widely used in the following applications:

1. Low Voltage Power Distribution

  • Feeder cables from transformers to main distribution boards (MDB)

  • Sub-main cables to distribution boards (SDB)

  • Final circuits for lighting and power outlets

2. Industrial Installations

  • Power supply to motors, pumps, compressors, and machinery

  • Control and auxiliary power circuits

  • Factory and workshop electrical systems

3. Commercial Buildings

  • Office buildings, shopping malls, hotels, and hospitals

  • Power supply to HVAC systems, elevators, and escalators

4. Residential Projects

  • Apartment buildings and housing complexes

  • Main riser cables and feeder circuits

5. Outdoor and Underground (with caution)

  • Cable trays, conduits, and ducts

  • Direct burial is possible in dry soil (armoured version recommended for high mechanical risk)

6. Infrastructure Projects

  • Street lighting and traffic signal power supply

  • Pumping stations, water treatment plants

  • Airports, ports, and railway stations

Construction Details



Layer Material Specification Function
Conductor Copper (plain) Class 1 (solid) or Class 2 (stranded) per IEC 60228 High conductivity, reliable current flow
Insulation PVC (Type TI) Voltage grade – 0.6/1kV Electrical isolation, dielectric strength
Core Identification Colored (Single core: Black/Brown; Multi-core: Black/Brown/Grey/Blue, etc.) Easy identification of phases and neutral
Core Assembly Cores twisted together (multi-core) Filler material maintains circular shape Compact construction, mechanical stability
Inner Sheath Optional (armoured versions only) Bedding for armour Protection of cores
Outer Sheath PVC (Type TM) Black (standard), UV stabilized, flame retardant Mechanical and environmental protection

*Note: This is the unarmoured version. For applications requiring mechanical protection (direct burial, rodent-prone areas), armoured versions (NYY-J / VV22 with steel tape armour or SWA) are available.*

Technical Specifications



Parameter Value
Rated Voltage (U₀/U) 0.6/1kV
Maximum Operating Voltage 1.2kV
Standard IEC 60502-1, GB/T 12706, BS 6346, VDE 0276
Conductor Material Copper (plain, 99.9% purity)
Conductor Types Class 1 (solid) or Class 2 (stranded) per IEC 60228
Conductor Sizes Available 1.5mm², 2.5mm², 4mm², 6mm², 10mm², 16mm², 25mm², 35mm², 50mm², 70mm², 95mm², 120mm², 150mm², 185mm², 240mm², 300mm², 400mm², 500mm², 630mm²
Number of Cores Single core, 2 core, 3 core, 4 core, 5 core, multi-core
Insulation Material PVC (Type TI) per IEC 60502-1
Insulation Thickness 0.8mm – 2.4mm (depending on conductor size)
Sheath Material PVC (Type TM) per IEC 60502-1
Sheath Color Black (standard), Grey, Red, Blue, Orange (custom)
Operating Temperature (Normal) -15°C to +70°C
Operating Temperature (Emergency Overload) +100°C (max)
Short Circuit Temperature +160°C (max, ≤5 seconds)
Minimum Installation Temperature 0°C (cable should be preheated if below 0°C)
Minimum Bending Radius (Multi-core) 12× overall diameter (unarmoured)
Minimum Bending Radius (Single core) 15 × overall diameter (unarmoured)
Flame Retardant Yes (inherent property of PVC)
UV Resistance Yes (black PVC sheath) – not suitable for white/light colors

Available Sizes & Current Ratings (Multi-core, 70°C PVC, in Air)

*Typical values – based on IEC 60502-1. Ratings for 3 or 4 core cables, ambient temperature 30°C, conductor temperature 70°C.*




Conductor Size (mm²) Approx. Overall Diameter (mm) Approx. Weight (kg/km) Current Rating (Air, 70°C) Current Rating (Buried, 70°C)
3 × 1.5mm² ~9 ~120 ~18A ~22A
3 × 2.5mm² ~10 ~170 ~24A ~29A
3 × 4mm² ~12 ~240 ~32A ~38A
3 × 6mm² ~13 ~330 ~41A ~47A
3 × 10mm² ~16 ~510 ~57A ~63A
3 × 16mm² ~19 ~750 ~76A ~82A
3 × 25mm² ~22 ~1100 ~101A ~105A
3 × 35mm² ~25 ~1450 ~125A ~129A
3 × 50mm² ~29 ~2000 ~151A ~154A
3 × 70mm² ~33 ~2750 ~192A ~191A
3 × 95mm² ~37 ~3650 ~232A ~228A
3 × 120mm² ~41 ~4600 ~269A ~263A
3 × 150mm² ~45 ~5650 ~308A ~299A
3 × 185mm² ~49 ~6900 ~352A ~338A
3 × 240mm² ~55 ~9000 ~413A ~394A



Values are indicative for multi-core unarmoured cable. Current ratings depend on installation conditions (ambient temperature, grouping, soil thermal resistivity). Please request official datasheet for exact specifications.

NYY vs VV – Naming Convention




Designation Standard Region Meaning
NYY European / IEC International N = Standard (VDE) / Y = PVC insulation / Y = PVC sheath
VV Chinese / GB China V = PVC insulation / V = PVC sheath



*Both designations refer to the same cable construction: Copper conductor, PVC insulation, PVC sheath, rated 0.6/1kV.*

Why Choose PVC Insulation and Sheath?




Feature PVC (Polyvinyl Chloride) Advantage
Cost Low Most economical insulation material
Flame retardancy Inherent Self-extinguishing, does not propagate fire
Moisture resistance Good Suitable for damp environments
Chemical resistance Good (oils, acids, alkalis) Performs well in industrial settings
Flexibility Good Easy to handle and install
UV resistance Good (black version) Suitable for outdoor use
Temperature rating 70°C continuous Adequate for most LV applications


Note: For applications requiring higher temperature rating (90°C continuous) or low smoke & halogen free properties, consider XLPE/LSZH alternatives.

Single Core vs Multi-core – Selection Guide




Number of Cores Application
Single core Phase conductor, DC applications, flexible installations, large cross-sections
2 core Single phase circuits (L + N)
3 core Three phase circuits (L1 + L2 + L3) without neutral
4 core Three phase + neutral (3L + N)
5 core Three phase + neutral + earth (3L + N + PE)



*For TN-S earthing systems, 5 core cables eliminate the need for a separate earth conductor.*

Standards Compliance




Standard Description
IEC 60502-1 Power cables with extruded insulation for rated voltages 1kV and 3kV
GB/T 12706.1 Chinese national standard equivalent to IEC 60502-1
BS 6346 British standard for PVC insulated armoured cables
VDE 0276-603 German standard for NYY cables
IEC 60228 Conductors of insulated cables
IEC 60332-1 Flame retardant – single vertical wire test


Optional certifications available upon request:

  • CE – European conformity

  • CCC – China Compulsory Certification

  • UL – For North American market (different construction)

  • ISO 9001 – Quality management system

Installation Guidelines

Preparation

  1. Inspect the cable for any damage to the PVC sheath before installation

  2. Store cables on clean, dry reels, protected from direct sunlight and moisture

  3. Preheat the cable if ambient temperature is below 0°C – cold cable can crack the PVC sheath

Pulling Tension

  • Maximum pulling tension (copper conductor): Approximately 50 × conductor cross-section (mm²) in Newtons

  • Use proper pulling grips (basket weave) – never pull by the insulation

Conduit Fill

  • Maximum recommended fill: 40% of conduit cross-sectional area for 3+ conductors

  • Use pulling lubricant for long runs

Termination

  • Strip back PVC sheath and insulation carefully – do not nick the copper conductor

  • Use properly sized copper lugs and terminals

  • Apply appropriate torque for termination screws

Testing After Installation

  • Perform insulation resistance test (minimum 100 MΩ)

  • Conduct continuity test on all conductors

  • High voltage test (3kV AC or 3.5kV DC for 15 minutes per IEC 60502-1)

Comparison with Other LV Power Cables




Feature NYY / VV (PVC/PVC) NA2XY / YJLV (Aluminum, XLPE) NYY-J / VV22 (Armoured)
Conductor Copper Aluminum Copper
Insulation PVC (70°C) XLPE (90°C) PVC (70°C)
Sheath PVC PVC PVC
Armour None None Steel tape or wire armour
Temperature rating 70°C 90°C 70°C
Weight Heavy Light Very heavy
Cost Moderate Lower Higher
Mechanical protection Low Low High
Direct burial suitability Limited Limited Yes
Typical application Indoor, tray, conduit Indoor, cost-saving projects Underground, harsh environments


Packaging & Delivery




Item Details
Packaging Wooden reels, steel reels, or coils (for small sizes)
Standard Length per Reel 500m, 1000m, or custom lengths
Reel marking Customer logo, sequential metering, project name (customizable)
Lead Time 10–20 days after deposit confirmation (standard sizes)
Shipping Methods Sea freight, air freight, express courier (sample orders)
Minimum Order Quantity (MOQ) 500 meters for standard sizes; sample orders accepted



Why Buy From Us?




Advantage Description
Direct manufacturer Competitive factory pricing, no middleman markups
IEC / GB certified Full compliance with international and Chinese standards
Wide size range Available from 1.5mm² to 630mm², single or multi-core
Free samples Available upon request (shipping cost only)
12-month warranty Against manufacturing defects
OEM/ODM supported Custom printing, sheath color, packaging, and labeling
Technical support Fast response to technical queries, installation guidance
Global shipping Experienced in export logistics worldwide

Frequently Asked Questions (FAQ)

Q: What does NYY stand for?
A: NYY is the European designation: N = Standard (VDE), Y = PVC insulation, Y = PVC sheath.

Q: What does VV stand for?
A: VV is the Chinese designation: V = PVC insulation, V = PVC sheath.

Q: Are NYY and VV the same cable?
A: Yes. They refer to the same construction: copper conductor, PVC insulation, PVC sheath, rated 0.6/1kV. NYY is the European naming convention, VV is the Chinese naming convention.

Q: What is the temperature rating of the PVC insulation?
A: PVC insulation is rated for 70°C continuous operation, 100°C emergency overload, and 160°C short circuit (≤5 seconds).

Q: Can this cable be used outdoors?
A: Yes. The black PVC sheath is UV stabilized for outdoor exposure. Light-colored sheaths (white, red, blue) are not recommended for direct sunlight.

Q: Is this cable suitable for direct burial?
A: The unarmoured version (NYY/VV) has limited direct burial suitability. For direct burial in areas with mechanical risk or rodents, we recommend the armoured version (NYY-J / VV22 with steel tape armour).

Q: Is this cable flame retardant?
A: Yes. PVC materials are inherently flame retardant and self-extinguishing. The cable complies with IEC 60332-1.

Q: What is the difference between Class 1 and Class 2 conductors?
A: Class 1 is solid copper (single wire) – used for small cross-sections (1.5-10mm²). Class 2 is stranded copper (multiple wires) – used for larger cross-sections and where flexibility is required.

Q: Do you provide free samples?
A: Yes, we provide free samples of NYY/VV cable. The customer is only responsible for the shipping cost.

Q: What is the typical lead time?
A: Typical lead time is 7–30 days after deposit confirmation, depending on order quantity and conductor size.

Q: Can I get custom printing on the cable?
A: Yes, we support OEM/ODM orders including custom printing (project name, customer logo, sequential metering, voltage marking).

Q: Is LSZH (Low Smoke Zero Halogen) version available?
A: Yes, we offer LSZH versions (N2XH / WDZ-YJY) for applications requiring low smoke and halogen-free properties. Please contact us for details.

Related Products

You may also be interested in:

  • NYY-J / VV22 (Steel Tape Armoured) – for direct burial and harsh environments

  • N2XH / WDZ-YJY (LSZH version) – for fire safety critical installations

  • NA2XY / YJLV (Aluminum conductor) – lightweight, cost-effective alternative

  • Low Voltage ABC (Aerial Bundle Cable) – for overhead distribution

  • Flexible cords (H05V-K, H07V-K) – for flexible connections and control circuits

OUR FACTORY 


0.6/1kV Copper Conductor PVC Insulation PVC Sheathed Power Cable – Low Voltage General Purpose Power Cable 0


PROJECTS


0.6/1kV Copper Conductor PVC Insulation PVC Sheathed Power Cable – Low Voltage General Purpose Power Cable 1


PARTNER


0.6/1kV Copper Conductor PVC Insulation PVC Sheathed Power Cable – Low Voltage General Purpose Power Cable 20.6/1kV Copper Conductor PVC Insulation PVC Sheathed Power Cable – Low Voltage General Purpose Power Cable 3



DELIVERY AND PACAKGE


0.6/1kV Copper Conductor PVC Insulation PVC Sheathed Power Cable – Low Voltage General Purpose Power Cable 4



Avaliações e Comentários

Classificação geral

5.0
Com base em 50 avaliações para este fornecedor

Instantâneo de classificação

A seguir está a distribuição de todas as classificações
5 estrelas
100%
4 estrelas
0%
3 estrelas
0%
2 estrelas
0%
1 estrelas
0%

Todos os comentários

A
A*s
Sri Lanka Nov 12.2025
fast delivery and good quality, so as the service
K
K*n
Vietnam Nov 10.2025
really good support and professional
N
N*
Kazakhstan Sep 16.2025
Professional factory and fast delivery, a pleasant cooperation
Contacto
Cai

Número de telefone : +8618991159926

Whatsapp : +8619829885532