logo
Encontrado 296 produtos para "

xlpe insulated wire

"
Qualidade 110kV XLPE Cable de cobre isolado de 630mm2 com bainha de alumínio ondulado soldado Fábrica

110kV XLPE Cable de cobre isolado de 630mm2 com bainha de alumínio ondulado soldado

Projetado para transmissão subterrânea de 110 kV, este cabo de cobre isolado em XLPE de 630 mm² apresenta uma bainha de alumínio corrugado soldado para enterramento direto 100% à prova d'água. Compatível com IEC 60840, ideal para subestações, redes subterrâneas urbanas e indústria pesada. FAT de terceiros suportado.

Qualidade Multi-Core LSZH Low Smoke Zero Halogen Cable XLPE Aço de arame blindado Fábrica

Multi-Core LSZH Low Smoke Zero Halogen Cable XLPE Aço de arame blindado

Multi Core Low Smoke Zero Halogen Cable XLPE Steel Wire Armoured Application For fixed installation of the transmission and distribution systems, tunnels and pipelines and other occasions .For situation not suppose to bear the external mechanical force. Constructions Conductor: Plain circular stranded copper conductor, conform to IEC 60228 class 2 Insulation: XLPE Amour: Steel Wire armour Core Conductor :annealed copper (stranded core) Popular sizes: 2~5 core x1.5~630mm²

Qualidade Cabo LSZH de Proteção Contra Incêndio, Três Condutores, MV 8,7/15kV, Isolamento XLPE, Armado com Fita de Aço, Cobertura de PVC Fábrica

Cabo LSZH de Proteção Contra Incêndio, Três Condutores, MV 8,7/15kV, Isolamento XLPE, Armado com Fita de Aço, Cobertura de PVC

Fire Protection LSZH Cable Three Core MV 8.7/15kV XLPE Insulated Steel Tape Armored PVC Sheathed Cable Product Overview Fire Rated Low Voltage Wire with 3 Core 1.5-400mm² is engineered to maintain circuit integrity during fire conditions, ensuring continuous power supply for critical emergency systems. Applications Suitable for power supply lines with flame retardant requirements, such as urban underground power grids, power station outgoing lines, and internal power lines of

Qualidade Cabo Condutor de Alumínio ACWU90 #8 AWG ATRAVÉS DE 750 kcmil XLPE/Alumínio Armado/Cabo PVC Fábrica

Cabo Condutor de Alumínio ACWU90 #8 AWG ATRAVÉS DE 750 kcmil XLPE/Alumínio Armado/Cabo PVC

ACWU90 Aluminium Conductor Cable #8 AWG THRU 750 kcmil XLPE/aluminium Armoured /PVC Cable APPLICATION Suitable for urban underground power grids, power station outgoing lines, internal power supply lines of industrial and mining enterprises, etc. CONSTRUCTION Conductor: 8 AWG. thru 750 kcmil aluminum (8000 series aluminum) compact class “B” strand Insulation: Cross-linked Polyethylene (XLPE) Type RW90 Bonding Conductor (Ground): One (1) bare stranded aluminum (ACM) conductor

Qualidade Cabo de energia de média tensão de núcleo único MV, com fita de cobre blindada, CU/XLPE/CTS/PVC Fábrica

Cabo de energia de média tensão de núcleo único MV, com fita de cobre blindada, CU/XLPE/CTS/PVC

Single Core MV Medium Voltage Power Cable Coppper Tape Screened CU/XLPE/CTS/PVC APPLICATION Single Core MV (Medium Voltage) Power Cable with Copper Tape Screen (CU/XLPE/CTS/PVC) is primarily designed for power transmission and distribution in medium voltage networks, typically operating within the 1kV to 35kV range. Its applications include underground installations, outdoor environments, and cable ducting systems, where reliable performance under challenging conditions is

Qualidade 0.6KV 1kv Cabos aéreos de baixa tensão 1 2 3 4 núcleos ABC XLPE isolado Fábrica

0.6KV 1kv Cabos aéreos de baixa tensão 1 2 3 4 núcleos ABC XLPE isolado

0.6/1kv Low Voltage Aerial Bundled Cable 1 2 3 4 Cores ABC Wire Applicatiom The aerial bundled cables designed for overhead distribution lines have all conductors made of aluminium, insulated with XLPE.Phase and neutral cores are laid up in a bundle with a left hand lay. Can be used for fixed installation as overhead power lines up to 1000V. Characteristics Voltage rating: 1kV Test voltage: 4kV, 5min no breakdown. Operating temperature PVC: -15°C to +70°C PE: -40°C to +70°C

Qualidade Cabos LSZH de baixa tensão AL/ XLPE/AWA/SWA/PVC NA2XRH IEC 60502-1 Fábrica

Cabos LSZH de baixa tensão AL/ XLPE/AWA/SWA/PVC NA2XRH IEC 60502-1

Low Voltage LSZH Cable AL/ XLPE/AWA/SWA/PVC NA2XRH IEC 60502-1 APPLICATION LSZH cable with steel wire armour (SWA) is used in power networks, underground, outdoor, indoor applications and in cable ducting. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. CONSTRUCTION Conductor :Class 2 stranded aluminium conductor Insulation :XLPE (Cross-Linked Polyethylene) Filler : LSZH (Low Smoke Zero Halogen) Armour :Single core:

Qualidade MV Steel Wire Armoured Cable CU/XLPE/CTS/STA/PVC Flame-retardant Power Cable Fábrica

MV Steel Wire Armoured Cable CU/XLPE/CTS/STA/PVC Flame-retardant Power Cable

MV Steel Wire Armoured Cable CU/XLPE/CTS/STA/PVC Flame-retardant Power Cable APPLICATION Industrial & Utility Power Distribution‌ Underground & Trench Laying‌ Flame-Retardant Environments‌ High-Temperature & Corrosive Conditions‌ Medium-Voltage Networks (Up to 35kV)‌ CONSUCTRUCTION Conductor: Compacted conductors Conductor Shield: Semi conductive shielding material (below 500mm 2 ) Semi conductive tape+semi conductive shielding material (500 mm 2 and above) Insulation:

Qualidade Cabos de aço com núcleo único, cabos blindados XLPE, condutores de cobre, cabos de média tensão. Fábrica

Cabos de aço com núcleo único, cabos blindados XLPE, condutores de cobre, cabos de média tensão.

Copper Conductor XLPE Insulated Power Cable Cu/XLPE/PVC/SWA Medium Voltage Cable Application XLPE (Cross-Linked Polyethylene) insulated cables are widely used in power transmission and distribution systems due to their high thermal resistance, mechanical strength, and excellent electrical insulation properties. They are commonly applied in medium- to high-voltage networks, underground and submarine installations, industrial plants, and commercial or residential buildings.