logo
KURMAK 296 için ürünler "

xlpe insulated wire

"
Kalite 110kV XLPE Isolasyonlu 630mm2 Bakır Kablo Fabrika

110kV XLPE Isolasyonlu 630mm2 Bakır Kablo

110kV yeraltı iletimi için tasarlanan bu XLPE yalıtımlı 630mm² bakır kablo, %100 su geçirmez doğrudan gömme için kaynaklı oluklu alüminyum kılıfa sahiptir. IEC 60840 uyumlu, trafo merkezleri, şehir şebekesi yeraltı ve ağır sanayi için idealdir. Üçüncü taraf FAT desteklenir.

Kalite Multi Core LSZH Düşük Duman Sıfır Halogen Kablo XLPE Çelik Tel Zırhlı Fabrika

Multi Core LSZH Düşük Duman Sıfır Halogen Kablo XLPE Çelik Tel Zırhlı

Multi Core Low Smoke Zero Halogen Cable XLPE Steel Wire Armoured Application For fixed installation of the transmission and distribution systems, tunnels and pipelines and other occasions .For situation not suppose to bear the external mechanical force. Constructions Conductor: Plain circular stranded copper conductor, conform to IEC 60228 class 2 Insulation: XLPE Amour: Steel Wire armour Core Conductor :annealed copper (stranded core) Popular sizes: 2~5 core x1.5~630mm²

Kalite Yangın Koruması LSZH Kablo Üç çekirdek MV 8.7/15kV XLPE yalıtımlı çelik bant zırhlı PVC kablo kablosu Fabrika

Yangın Koruması LSZH Kablo Üç çekirdek MV 8.7/15kV XLPE yalıtımlı çelik bant zırhlı PVC kablo kablosu

Fire Protection LSZH Cable Three Core MV 8.7/15kV XLPE Insulated Steel Tape Armored PVC Sheathed Cable Product Overview Fire Rated Low Voltage Wire with 3 Core 1.5-400mm² is engineered to maintain circuit integrity during fire conditions, ensuring continuous power supply for critical emergency systems. Applications Suitable for power supply lines with flame retardant requirements, such as urban underground power grids, power station outgoing lines, and internal power lines of

Kalite ACWU90 Alüminyum İletken Kablo #8 AWG İLE 750 kcmil XLPE/alüminyum Zırhlı/PVC Kablo Fabrika

ACWU90 Alüminyum İletken Kablo #8 AWG İLE 750 kcmil XLPE/alüminyum Zırhlı/PVC Kablo

ACWU90 Aluminium Conductor Cable #8 AWG THRU 750 kcmil XLPE/aluminium Armoured /PVC Cable APPLICATION Suitable for urban underground power grids, power station outgoing lines, internal power supply lines of industrial and mining enterprises, etc. CONSTRUCTION Conductor: 8 AWG. thru 750 kcmil aluminum (8000 series aluminum) compact class “B” strand Insulation: Cross-linked Polyethylene (XLPE) Type RW90 Bonding Conductor (Ground): One (1) bare stranded aluminum (ACM) conductor

Kalite Tek Damarlı OG Orta Gerilim Güç Kablosu Bakır Bant Ekranlı CU/XLPE/CTS/PVC Fabrika

Tek Damarlı OG Orta Gerilim Güç Kablosu Bakır Bant Ekranlı CU/XLPE/CTS/PVC

Single Core MV Medium Voltage Power Cable Coppper Tape Screened CU/XLPE/CTS/PVC APPLICATION Single Core MV (Medium Voltage) Power Cable with Copper Tape Screen (CU/XLPE/CTS/PVC) is primarily designed for power transmission and distribution in medium voltage networks, typically operating within the 1kV to 35kV range. Its applications include underground installations, outdoor environments, and cable ducting systems, where reliable performance under challenging conditions is

Kalite 0.6KV 1kv Düşük Voltajlı Aerial Bundled Kablo 1 2 3 4 çekirdekler ABC Kablo XLPE yalıtımlı Fabrika

0.6KV 1kv Düşük Voltajlı Aerial Bundled Kablo 1 2 3 4 çekirdekler ABC Kablo XLPE yalıtımlı

0.6/1kv Low Voltage Aerial Bundled Cable 1 2 3 4 Cores ABC Wire Applicatiom The aerial bundled cables designed for overhead distribution lines have all conductors made of aluminium, insulated with XLPE.Phase and neutral cores are laid up in a bundle with a left hand lay. Can be used for fixed installation as overhead power lines up to 1000V. Characteristics Voltage rating: 1kV Test voltage: 4kV, 5min no breakdown. Operating temperature PVC: -15°C to +70°C PE: -40°C to +70°C

Kalite AL/ XLPE/AWA/SWA/PVC NA2XRH IEC 60502-1 Fabrika

AL/ XLPE/AWA/SWA/PVC NA2XRH IEC 60502-1

Low Voltage LSZH Cable AL/ XLPE/AWA/SWA/PVC NA2XRH IEC 60502-1 APPLICATION LSZH cable with steel wire armour (SWA) is used in power networks, underground, outdoor, indoor applications and in cable ducting. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. CONSTRUCTION Conductor :Class 2 stranded aluminium conductor Insulation :XLPE (Cross-Linked Polyethylene) Filler : LSZH (Low Smoke Zero Halogen) Armour :Single core:

Kalite MV Steel Wire Armoured Cable CU/XLPE/CTS/STA/PVC Flame-retardant Power Cable Fabrika

MV Steel Wire Armoured Cable CU/XLPE/CTS/STA/PVC Flame-retardant Power Cable

MV Steel Wire Armoured Cable CU/XLPE/CTS/STA/PVC Flame-retardant Power Cable APPLICATION Industrial & Utility Power Distribution‌ Underground & Trench Laying‌ Flame-Retardant Environments‌ High-Temperature & Corrosive Conditions‌ Medium-Voltage Networks (Up to 35kV)‌ CONSUCTRUCTION Conductor: Compacted conductors Conductor Shield: Semi conductive shielding material (below 500mm 2 ) Semi conductive tape+semi conductive shielding material (500 mm 2 and above) Insulation:

Kalite Tek çekirdekli çelik tel zırhlı XLPE kablosu, bakır iletken orta gerilimli kablo Fabrika

Tek çekirdekli çelik tel zırhlı XLPE kablosu, bakır iletken orta gerilimli kablo

Copper Conductor XLPE Insulated Power Cable Cu/XLPE/PVC/SWA Medium Voltage Cable Application XLPE (Cross-Linked Polyethylene) insulated cables are widely used in power transmission and distribution systems due to their high thermal resistance, mechanical strength, and excellent electrical insulation properties. They are commonly applied in medium- to high-voltage networks, underground and submarine installations, industrial plants, and commercial or residential buildings.