electrical wire cable
"
کابل خورشیدی عایق شده XLPE سیم پنل خورشیدی PV الکتریکی 1.5MM 2.5MM PV1-F
XLPE Insulated Solar Cable Electric PV Wire 1.5MM 2.5MM PV1-F Application Solar cables are the designated cable used for rooftop PV installations. They are suitable for free hanging, movable, fixed installation and buried in ground in constructional covered systems indoor, outdoor or in hazard explosion areas, in industry and agriculture. Cable performance Properties such as moisture and heat resistance, high and low temperature resistance, acid and alkali resistance,ozone
35kV MV XLPE کابل الکتریکی سیم مس سپر 3 هسته طول سفارشی
35kV MV XLPE Insulated Power Cable Copper Wire Shield XLPE/PVC/STA AA-8000 Series Application Used for tall building, Hospital, Theatre, Power station, Metro Tunnel or Petrochemical Industry or other special place required for low smoke , zero halogen clean and safe cable. Construction 1. Conductor Round compacted conductors 2. Conductor Shield Semi conductive shielding material (below 500mm 2 Semi conductive tape+semi conductive shielding material (500 mm2 and above) 3.
کابل برق هادی آلومینیومی تک رشته ای، کابل زیرزمینی ولتاژ متوسط برای مصارف الکتریکی
Single Core Aluminium Conductor Power cable Medium Voltage Underground Cable for Electrical Use APPLICATION Single-core aluminium conductor power cables with medium voltage ratings (typically 6kV–36kV) are widely used in the following scenarios Power Distribution Networks Industrial Facilities Infrastructure Projects Renewable Energy CONSTRUCTION Conductor: Round compacted conductors Conductor Shield: Semi conductive shielding material (below 500mm2 ) Semi
کابل کنترل عایق PVC NYY، NYCY، NYSY، NYBY
PVC Insulated Control Cable NYY, NYCY, NYSY, NYBY APPLICATION Underground and industrial power transmission, especially in wet or corrosive environments. ndustrial control circuits requiring flexibility and resistance to environmental stress. Fixed installations in dry or moderately humid environments, such as control panels. CONSTRUCTION Conductor: Class 5 soft stranded conductor Insulation: Polyvinyl chloride (PVC) Filler( optional ): Polypropylene (PP) Mesh Filling Rope
کابل برق زرهی مقاوم در برابر شعله CU/XLPE/AWA/SWA/PE برای انتقال نیرو
Flame Retardant Armoured Power Cable CU/XLPE/AWA/SWA/PE for Power Transmission APPLICATION Flame Retardant Armoured Power Cable CU/XLPE/AWA/SWA/PE for Power Transmission is a high-performance cable designed for safe and reliable power transmission in demanding environments CONSTRUCTION Conductor: Class 1/ Class 2 stranded Copper conductor Refractory layer: Single sided gold mica tape Insulation: XLPE Filler ( options ): Polypropylene mesh tear rope or flame-retardant filling
کابل زرهی 1.5mm2 SWA 3.6-35kV AL/XLPE/CWS/CTS/SWA/PVC برای توزیع برق
1.5mm2 SWA Armoured Cable 3.6-35kV AL/XLPE/CWS/CTS/SWA/PVC for Power Distribution Application The core application of this 1.5mm² SWA Armoured Cable 3.6-35kV AL/XLPE/CWS/CTS/SWA/PVC is medium-voltage power underground direct burial, conduit installation, or fixed wiring. It is particularly suitable for occasions requiring mechanical protection and tensile strength, such as power distribution networks, industrial facilities, or infrastructure construction. Construction
کابل زره ای آلومینیومی گواهینامه CE AL/XLPE/STA/SWA/PVC 240mm2 کابل
CE Certified Aluminium Armoured Cable AL/XLPE/STA/SWA/PVC 240mm2 Cable Constuction ✔ XLPE Insulation (Cross-linked polyethylene) - Superior thermal stability (90°C rated) ✔ PVC Outer Sheath - UV resistant formulation (custom LSZH/Fire-resistant options availabl e)✔ Dual Certification - Compliant with IEC 60502-1 & GB/T 12706.1✔ Optional Armoring - Steel tape (YJLV22) or wire (YJLV32) for mechanical protection Advantages: ✔ Lower Power Loss – XLPE insulation ensures higher
کابل آلومینیومی و فولادی زره دار NA2XRY هادی آلومینیومی IEC 60502-1
Aluminium Wire and Steel Wire Armoured Cable NA2XRY Aluminium Conductor IEC 60502-1 Applications The cables is mainly used for low-voltage(0.6/1kV) underground power distribution in industrial, commercial, and infrastructure projects requiring mechanical protection. Construction 1. Conductor: Class 1 or Class2 aluminum 2. XLPE Insulation 3. Alumiunium Wire Armoured (single core )or Steel Wire Armoured(Multi core) 4. PVC or polyethylene sheath. Characteristics Voltage Rating
کابل آلومینیومی تک هسته ای با عایق XLPE و زره سیمی (AWA) مطابق با استاندارد BS 5467
Single Core Aluminium Conductor XLPE Insulated AWA Cable to BS 5467 Standard Application Single core aluminium conductor XLPE insulated AWA cable to BS 5467 is widely used for underground and outdoor power distribution, offering excellent mechanical protection and reliable performance in AC systems. Construction The Single Core Aluminium Conductor XLPE Insulated Aluminium Wire Armoured (AWA) Cable to BS 5467 is designed with a robust multilayer construction to ensure reliable