logo
발견 379 제품 "

xlpe insulated cable

"
품질 26/35kV AWA 장갑 케이블 CU/XLPE/AWA/PVC/PE 껍질로 된 방화 retardant 전력 케이블 공장

26/35kV AWA 장갑 케이블 CU/XLPE/AWA/PVC/PE 껍질로 된 방화 retardant 전력 케이블

26/35kV AWA Armoured Cable CU/XLPE/AWA/PVC/PE Sheathed Flame-retardant Power Cable Application The 26/35kV AWA (Aluminium Wire Armoured) copper conductor power cable is designed for medium voltage power transmission and distribution systems up to 35kV. It is widely used in applications requiring high reliability, mechanical protection, and fire safety performance. Main Construction Conductor: Compacted conductors Insulation: PVC Metal Screen: Copper Tape Armouring: Aluminium

품질 LSZH 산업 및 공공 인프라를 위한 구리 선도자와 XLPE 단열을 가진 저전압 케이블 공장

LSZH 산업 및 공공 인프라를 위한 구리 선도자와 XLPE 단열을 가진 저전압 케이블

LSZH Low Voltage STA Low Smoke Zero Halogen Cable N2X2Y Applications Industrial Machinery Public Infrastructure Renewable Energy Systems Underground or Duct Installation Temporary Power Supply Fire-Sensitive Areas Construction Conductor: Class 1/Class 2 stranded Copper conductor Refractory layer: Single sided gold mica tape Insulation: XLPE Filler (options): Polypropylene mesh tear rope or flame-retardant filling Outer sheath: LOSH Characteristics Voltage Rating: Uo/U: 0.6

품질 MV Steel Wire Armoured Cable CU/XLPE/CTS/STA/PVC Flame-retardant Power Cable 공장

MV Steel Wire Armoured Cable CU/XLPE/CTS/STA/PVC Flame-retardant Power Cable

MV Steel Wire Armoured Cable CU/XLPE/CTS/STA/PVC Flame-retardant Power Cable APPLICATION Industrial & Utility Power Distribution‌ Underground & Trench Laying‌ Flame-Retardant Environments‌ High-Temperature & Corrosive Conditions‌ Medium-Voltage Networks (Up to 35kV)‌ CONSUCTRUCTION Conductor: Compacted conductors Conductor Shield: Semi conductive shielding material (below 500mm 2 ) Semi conductive tape+semi conductive shielding material (500 mm 2 and above) Insulation:

품질 저전압 LSZH 케이블 AL/ XLPE/AWA/SWA/PVC NA2XRH IEC 60502-1 공장

저전압 LSZH 케이블 AL/ XLPE/AWA/SWA/PVC NA2XRH IEC 60502-1

Low Voltage LSZH Cable AL/ XLPE/AWA/SWA/PVC NA2XRH IEC 60502-1 APPLICATION LSZH cable with steel wire armour (SWA) is used in power networks, underground, outdoor, indoor applications and in cable ducting. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. CONSTRUCTION Conductor :Class 2 stranded aluminium conductor Insulation :XLPE (Cross-Linked Polyethylene) Filler : LSZH (Low Smoke Zero Halogen) Armour :Single core:

품질 0.6KV 1kv 저전압 에어리언 팩들드 케이블 1 2 3 4 코어 ABC 와이어 XLPE 단열 공장

0.6KV 1kv 저전압 에어리언 팩들드 케이블 1 2 3 4 코어 ABC 와이어 XLPE 단열

0.6/1kv Low Voltage Aerial Bundled Cable 1 2 3 4 Cores ABC Wire Applicatiom The aerial bundled cables designed for overhead distribution lines have all conductors made of aluminium, insulated with XLPE.Phase and neutral cores are laid up in a bundle with a left hand lay. Can be used for fixed installation as overhead power lines up to 1000V. Characteristics Voltage rating: 1kV Test voltage: 4kV, 5min no breakdown. Operating temperature PVC: -15°C to +70°C PE: -40°C to +70°C

품질 난연 저전압 케이블 4심 0.6/1kV CU/XLPE/STA/PVC 산업용 케이블 공장

난연 저전압 케이블 4심 0.6/1kV CU/XLPE/STA/PVC 산업용 케이블

Flame Retardant Low Voltage Cable 4 Core 0.6/1kV CU/XLPE/ STA/PVC Industrial Cable APPLICATION This product is suitable for use in circuits with a rated voltage not exceeding 0.6/1kV, for the purpose of power transmission and distribution. CONSTRUCTION Conductor: Class 1 or class 2 stranded Copper conductor Insulation: Cross-Linked Polyethylene(XLPE) Inner sheath: Polyvinyl chloride (PVC) Armour: Single core: Steel Tape Multi core: Galvanized Steel Tape Outer sheath:

품질 3 코어 스트랜드 알루미늄 장갑 케이블 AL/PVC/STA/PVC 저전압 600/1000V 공장

3 코어 스트랜드 알루미늄 장갑 케이블 AL/PVC/STA/PVC 저전압 600/1000V

Three core Stranded Aluminium Armored cable AL/PVC/STA/PVC Low Voltage 600/1000V Applications The cable is designed for fixed installation where mechanical protection and cost efficiency are required, such as industrial power distribution, buildings, underground installation, street power supply and etc. Construction 1. Conductor: Stranded aluminum 2. PVC Insulation 3. Steel Tape or Steel Wire Armoured. 4. PVC or polyethylene sheath. 5. Number of cable cores: three cores

품질 Fire-Resistant XLPE Insulated Single Core Power Cable 0.6/1kV IEC 60331 for Emergency Safety Circuits 공장

Fire-Resistant XLPE Insulated Single Core Power Cable 0.6/1kV IEC 60331 for Emergency Safety Circuits

IEC 60331에 따라 설계된 이 내화성 단일 코어 XLPE 전원 케이블은 화재 발생 시 회로 무결성이 필요한 비상 시스템을 위한 운모 테이프 배리어 기술을 갖추고 있습니다. 병원, 터널, 고층 건물의 소방 펌프, 대피 조명 및 안전 회로에 이상적입니다.

품질 LSZH 껍질 보호 기기 케이블 2 3 4 5 멀티 코어 CU XLPE LSZH 공장

LSZH 껍질 보호 기기 케이블 2 3 4 5 멀티 코어 CU XLPE LSZH

LSZH Sheath Shielded Instrument Cable 2345 Multcore CU/XLPE/LSZH Application Low-smoke zero-halogen (LSZH) shielded instrumentation cables are designed for critical applications requiring ‌ fire safety, signal integrity, and environmental protection Construction Specificatrion Type Designation Applications YJV Copper conductor,XLPE insulated,PVC sheathed power cable For laying indoors,in tunnel or cable trench,unable to bear external mechanical forces.Single core cable is not