logo
見つかりました 379 のための製品 "

xlpe insulated cable

"
品質 26/35kV AWA armouredケーブル CU/XLPE/AWA/PVC/PE シース難燃性電力ケーブル 工場

26/35kV AWA armouredケーブル CU/XLPE/AWA/PVC/PE シース難燃性電力ケーブル

26/35kV AWA Armoured Cable CU/XLPE/AWA/PVC/PE Sheathed Flame-retardant Power Cable Application The 26/35kV AWA (Aluminium Wire Armoured) copper conductor power cable is designed for medium voltage power transmission and distribution systems up to 35kV. It is widely used in applications requiring high reliability, mechanical protection, and fire safety performance. Main Construction Conductor: Compacted conductors Insulation: PVC Metal Screen: Copper Tape Armouring: Aluminium

品質 LSZH 低電圧ケーブル、銅導体および XLPE 絶縁、産業および公共インフラ用 工場

LSZH 低電圧ケーブル、銅導体および XLPE 絶縁、産業および公共インフラ用

LSZH Low Voltage STA Low Smoke Zero Halogen Cable N2X2Y Applications Industrial Machinery Public Infrastructure Renewable Energy Systems Underground or Duct Installation Temporary Power Supply Fire-Sensitive Areas Construction Conductor: Class 1/Class 2 stranded Copper conductor Refractory layer: Single sided gold mica tape Insulation: XLPE Filler (options): Polypropylene mesh tear rope or flame-retardant filling Outer sheath: LOSH Characteristics Voltage Rating: Uo/U: 0.6

品質 MV Steel Wire Armoured Cable CU/XLPE/CTS/STA/PVC Flame-retardant Power Cable 工場

MV Steel Wire Armoured Cable CU/XLPE/CTS/STA/PVC Flame-retardant Power Cable

MV Steel Wire Armoured Cable CU/XLPE/CTS/STA/PVC Flame-retardant Power Cable APPLICATION Industrial & Utility Power Distribution‌ Underground & Trench Laying‌ Flame-Retardant Environments‌ High-Temperature & Corrosive Conditions‌ Medium-Voltage Networks (Up to 35kV)‌ CONSUCTRUCTION Conductor: Compacted conductors Conductor Shield: Semi conductive shielding material (below 500mm 2 ) Semi conductive tape+semi conductive shielding material (500 mm 2 and above) Insulation:

品質 低電圧LSZHケーブル AL/XLPE/AWA/SWA/PVC NA2XRH IEC 60502-1 工場

低電圧LSZHケーブル AL/XLPE/AWA/SWA/PVC NA2XRH IEC 60502-1

Low Voltage LSZH Cable AL/ XLPE/AWA/SWA/PVC NA2XRH IEC 60502-1 APPLICATION LSZH cable with steel wire armour (SWA) is used in power networks, underground, outdoor, indoor applications and in cable ducting. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. CONSTRUCTION Conductor :Class 2 stranded aluminium conductor Insulation :XLPE (Cross-Linked Polyethylene) Filler : LSZH (Low Smoke Zero Halogen) Armour :Single core:

品質 0.6KV 1kv 低電圧アンテナ バンドケーブル 1 2 3 4 コア ABCワイヤ XLPE 隔離 工場

0.6KV 1kv 低電圧アンテナ バンドケーブル 1 2 3 4 コア ABCワイヤ XLPE 隔離

0.6/1kv Low Voltage Aerial Bundled Cable 1 2 3 4 Cores ABC Wire Applicatiom The aerial bundled cables designed for overhead distribution lines have all conductors made of aluminium, insulated with XLPE.Phase and neutral cores are laid up in a bundle with a left hand lay. Can be used for fixed installation as overhead power lines up to 1000V. Characteristics Voltage rating: 1kV Test voltage: 4kV, 5min no breakdown. Operating temperature PVC: -15°C to +70°C PE: -40°C to +70°C

品質 耐火低電圧ケーブル 4コア 0.6/1kV CU/XLPE/STA/PVC産業ケーブル 工場

耐火低電圧ケーブル 4コア 0.6/1kV CU/XLPE/STA/PVC産業ケーブル

Flame Retardant Low Voltage Cable 4 Core 0.6/1kV CU/XLPE/ STA/PVC Industrial Cable APPLICATION This product is suitable for use in circuits with a rated voltage not exceeding 0.6/1kV, for the purpose of power transmission and distribution. CONSTRUCTION Conductor: Class 1 or class 2 stranded Copper conductor Insulation: Cross-Linked Polyethylene(XLPE) Inner sheath: Polyvinyl chloride (PVC) Armour: Single core: Steel Tape Multi core: Galvanized Steel Tape Outer sheath:

品質 3コア ストランディング アルミ 装甲ケーブル AL/PVC/STA/PVC 低電圧 600/1000V 工場

3コア ストランディング アルミ 装甲ケーブル AL/PVC/STA/PVC 低電圧 600/1000V

Three core Stranded Aluminium Armored cable AL/PVC/STA/PVC Low Voltage 600/1000V Applications The cable is designed for fixed installation where mechanical protection and cost efficiency are required, such as industrial power distribution, buildings, underground installation, street power supply and etc. Construction 1. Conductor: Stranded aluminum 2. PVC Insulation 3. Steel Tape or Steel Wire Armoured. 4. PVC or polyethylene sheath. 5. Number of cable cores: three cores

品質 Fire-Resistant XLPE Insulated Single Core Power Cable 0.6/1kV IEC 60331 for Emergency Safety Circuits 工場

Fire-Resistant XLPE Insulated Single Core Power Cable 0.6/1kV IEC 60331 for Emergency Safety Circuits

IEC 60331 に準拠して設計されたこの耐火性シングル コア XLPE 電源ケーブルは、火災時に回路の完全性が必要な緊急システム向けにマイカ テープ バリア技術を採用しています。消防ポンプ、避難照明、病院、トンネル、高層ビルの安全回路に最適です。

品質 LSZH カーブシールド機器ケーブル 2 3 4 5 多核 CU XLPE LSZH 工場

LSZH カーブシールド機器ケーブル 2 3 4 5 多核 CU XLPE LSZH

LSZH Sheath Shielded Instrument Cable 2345 Multcore CU/XLPE/LSZH Application Low-smoke zero-halogen (LSZH) shielded instrumentation cables are designed for critical applications requiring ‌ fire safety, signal integrity, and environmental protection Construction Specificatrion Type Designation Applications YJV Copper conductor,XLPE insulated,PVC sheathed power cable For laying indoors,in tunnel or cable trench,unable to bear external mechanical forces.Single core cable is not