logo
발견 217 제품 "

low voltage power cable

"
품질 단일 코어 0.6/1kV AWA 장갑 케이블 N2XRY / NA2XRY CU ((AL) / XLPE/AWA/PVC 전원 케이블 공장

단일 코어 0.6/1kV AWA 장갑 케이블 N2XRY / NA2XRY CU ((AL) / XLPE/AWA/PVC 전원 케이블

Single Core 0.6/1kV AWA Armoured Cable N2XRY / NA2XRY CU(AL)/XLPE/AWA/PVC Power Cable Product Overview The Single Core 0.6/1kV N2XRY / NA2XRY CU(AL)/XLPE/AWA/PVC Power Cable is a low-voltage aluminium wire armoured power cable designed for fixed installation in industrial, commercial, and utility power distribution systems. Manufactured with high-quality copper or aluminium conductors, XLPE insulation, Aluminium Wire Armour (AWA), and durable PVC outer sheath, the cable

품질 구리 와이어 스크린 저전압 케이블 단일 코어 0.6/1kV PVC 단열 케이블 공장

구리 와이어 스크린 저전압 케이블 단일 코어 0.6/1kV PVC 단열 케이블

Copper Wire Screen Low Voltage Cable Single Core 0.6/1kV PVC Insulated Cable APPLICATION Copper-shielded low-voltage cables are widely used in environments requiring reliable power transmission with electromagnetic interference (EMI) protection CONSTRUCTION Conductor:Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation:XLPE Filler: Non-hygroscopic material Screen: Copper Wire Binder tape:: Non-hygroscopic material Sheath PVC Characteristics Test

품질 구리 XLPE 장갑 전력 케이블 95-630mm2 불 retardant 공장

구리 XLPE 장갑 전력 케이블 95-630mm2 불 retardant

95mm2 120mm2 240mm2 300mm2 630mm2 Armoured CU/XLPE/STA/PVC Flame Retardant Power Cable APPLICATION Power Distribution Networks Widely used in urban underground power grids, industrial parks, and substation connections for medium-voltage (0.6/1kV) power transmission. Suitable for both overhead and underground installations due to its armored (steel tape armor) structure. Industrial Facilities Deployed in manufacturing plants, oil refineries, and chemical industries where flame

품질 660/1100V 저전압 케이블 Vvg Vvgng Vvgng-Frls 구리 전력 케이블 EAC 인증 케이블 공장

660/1100V 저전압 케이블 Vvg Vvgng Vvgng-Frls 구리 전력 케이블 EAC 인증 케이블

660/1100V Low Voltage Cable Vvg Vvgng Vvgng-Frls Copper Power Cable EAC Certified Cable APPLICATION Construction, Underground, Industrial, Power Station CONSTRUCTION Conductor: Class 2 stranded Copper conductor Insulation: Cross-Linked Polyethylene(XLPE) Outer sheath: Polyvinyl chloride (PVC) CHARACTERICSTIC Voltage Rating Uo/U: 0.6/1kV M aximum system voltage: 12kV Maximum operating temperature of conductor: +90℃ Operating ambient temperature: -20℃~+45℃ Cable laying

품질 지하 전력 유통용으로 3 코어와 LSZH를 갖춘 소압 케이블 공장

지하 전력 유통용으로 3 코어와 LSZH를 갖춘 소압 케이블

Fire Rated Low Voltage Wire N2XY with 3 Core 1.5-400mm² Underground Power Cable Product Overview Fire Rated Low Voltage Wire with 3 Core 1.5-400mm² is engineered to maintain circuit integrity during fire conditions, ensuring continuous power supply for critical emergency systems. Applications This fire-resistant cable is specifically designed for critical systems including emergency lighting, fire alarms, and evacuation systems. Its three-core configuration (phase, neutral,

품질 강철 테이프 장갑 STA 저전압 케이블 2 코어 XLPE 단열 CU AL 전도기 공장

강철 테이프 장갑 STA 저전압 케이블 2 코어 XLPE 단열 CU AL 전도기

Steel Tape Armoured STA Low Voltage Cable Two Core XLPE Insulated CU AL Conductor Application This XLPE insulated steel tape armored power cable is used in underground power transmission lines of rated voltage 1KV and below. Steel tape armor allows the power cable to bear considerable vertical pressures. Construction Conductor: Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation: Cross-linked polyethylene (XLPE). Inner covering:PVC Armouring:

품질 내화 XLPE 절연 전력 케이블 1.5-800mm2 1-5심 CU/XLPE/PVC 공장

내화 XLPE 절연 전력 케이블 1.5-800mm2 1-5심 CU/XLPE/PVC

Fire Resistant XLPE Insulated Power Cable 1.5-800mm2 1-5 Core CU/XLPE/PVC APPLICATION The cable is a ‌fire-resistant , ‌XLPE-insulated , and ‌PVC-sheathed power cable rated for voltages up to ‌0.6/1 kV ‌. It is widely used in: ‌Power Distribution Systems ‌ – Suitable for fixed installations in buildings, industrial plants, and infrastructure projects, delivering reliable power transmission in low-voltage networks. Fire Safety Critical Areas ‌ – The ‌"N" (fire-resistant) ‌

품질 구리 도체 및 XLPE 절연을 사용한 0.6/1kV 저전압 내화 케이블 (화재 안전 적용) 공장

구리 도체 및 XLPE 절연을 사용한 0.6/1kV 저전압 내화 케이블 (화재 안전 적용)

Low Voltage Fire Rated Cable 0.6/1kV CU/XLPE/PE YJY N2X2Y This fire-resistant cable is designed for low-voltage power distribution systems where fire safety is critical, rated for 0.6/1kV applications. Applications Suitable for installation in cable ducts, underground applications, and exposed installations in various industrial and commercial environments. Construction Details Conductor: Class 1/Class 2 stranded copper conductor Refractory layer: Single-sided gold mica tape

품질 강철 테이프 아머드 전력 케이블 CU/XLPE/STA/PVC 중전압 산업용 철도 지하용 공장

강철 테이프 아머드 전력 케이블 CU/XLPE/STA/PVC 중전압 산업용 철도 지하용

Steel Tape Armored Power Cable CU/XLPE/STA/PVC Medium Voltage for Industrial Railway Underground Applications These cables are used for electricity supply in medium voltage installation system, they are suitable for installation in indoors and outdoors, in cable ducts, underground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage. Construction Copper Core: Provides superior conductivity and durability

이전
페이지 7 의 25