logo
見つかりました 217 のための製品 "

low voltage power cable

"
品質 シングルコア0.6/1kV AWA装甲ケーブル N2XRY / NA2XRY CU ((AL) /XLPE/AWA/PVC電源ケーブル 工場

シングルコア0.6/1kV AWA装甲ケーブル N2XRY / NA2XRY CU ((AL) /XLPE/AWA/PVC電源ケーブル

Single Core 0.6/1kV AWA Armoured Cable N2XRY / NA2XRY CU(AL)/XLPE/AWA/PVC Power Cable Product Overview The Single Core 0.6/1kV N2XRY / NA2XRY CU(AL)/XLPE/AWA/PVC Power Cable is a low-voltage aluminium wire armoured power cable designed for fixed installation in industrial, commercial, and utility power distribution systems. Manufactured with high-quality copper or aluminium conductors, XLPE insulation, Aluminium Wire Armour (AWA), and durable PVC outer sheath, the cable

品質 銅ワイヤスクリーン 低電圧ケーブル 単核 0.6/1kV PVC隔離ケーブル 工場

銅ワイヤスクリーン 低電圧ケーブル 単核 0.6/1kV PVC隔離ケーブル

Copper Wire Screen Low Voltage Cable Single Core 0.6/1kV PVC Insulated Cable APPLICATION Copper-shielded low-voltage cables are widely used in environments requiring reliable power transmission with electromagnetic interference (EMI) protection CONSTRUCTION Conductor:Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation:XLPE Filler: Non-hygroscopic material Screen: Copper Wire Binder tape:: Non-hygroscopic material Sheath PVC Characteristics Test

品質 銅型XLPE装甲電源ケーブル 95-630mm2 阻燃性 工場

銅型XLPE装甲電源ケーブル 95-630mm2 阻燃性

95mm2 120mm2 240mm2 300mm2 630mm2 Armoured CU/XLPE/STA/PVC Flame Retardant Power Cable APPLICATION Power Distribution Networks Widely used in urban underground power grids, industrial parks, and substation connections for medium-voltage (0.6/1kV) power transmission. Suitable for both overhead and underground installations due to its armored (steel tape armor) structure. Industrial Facilities Deployed in manufacturing plants, oil refineries, and chemical industries where flame

品質 660/1100V低電圧ケーブル Vvg Vvgng Vvgng-Frls銅電源ケーブル EAC認定ケーブル 工場

660/1100V低電圧ケーブル Vvg Vvgng Vvgng-Frls銅電源ケーブル EAC認定ケーブル

660/1100V Low Voltage Cable Vvg Vvgng Vvgng-Frls Copper Power Cable EAC Certified Cable APPLICATION Construction, Underground, Industrial, Power Station CONSTRUCTION Conductor: Class 2 stranded Copper conductor Insulation: Cross-Linked Polyethylene(XLPE) Outer sheath: Polyvinyl chloride (PVC) CHARACTERICSTIC Voltage Rating Uo/U: 0.6/1kV M aximum system voltage: 12kV Maximum operating temperature of conductor: +90℃ Operating ambient temperature: -20℃~+45℃ Cable laying

品質 地下電源配給用の3コアとLSZHの低電圧ケーブル 工場

地下電源配給用の3コアとLSZHの低電圧ケーブル

Fire Rated Low Voltage Wire N2XY with 3 Core 1.5-400mm² Underground Power Cable Product Overview Fire Rated Low Voltage Wire with 3 Core 1.5-400mm² is engineered to maintain circuit integrity during fire conditions, ensuring continuous power supply for critical emergency systems. Applications This fire-resistant cable is specifically designed for critical systems including emergency lighting, fire alarms, and evacuation systems. Its three-core configuration (phase, neutral,

品質 鋼テープ 装甲型 STA 低電圧ケーブル 2コア XLPE 絶縁式 CU AL 導体 工場

鋼テープ 装甲型 STA 低電圧ケーブル 2コア XLPE 絶縁式 CU AL 導体

Steel Tape Armoured STA Low Voltage Cable Two Core XLPE Insulated CU AL Conductor Application This XLPE insulated steel tape armored power cable is used in underground power transmission lines of rated voltage 1KV and below. Steel tape armor allows the power cable to bear considerable vertical pressures. Construction Conductor: Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation: Cross-linked polyethylene (XLPE). Inner covering:PVC Armouring:

品質 耐火性XLPE絶縁電力ケーブル 1.5-800mm2 1-5心 CU/XLPE/PVC 工場

耐火性XLPE絶縁電力ケーブル 1.5-800mm2 1-5心 CU/XLPE/PVC

Fire Resistant XLPE Insulated Power Cable 1.5-800mm2 1-5 Core CU/XLPE/PVC APPLICATION The cable is a ‌fire-resistant , ‌XLPE-insulated , and ‌PVC-sheathed power cable rated for voltages up to ‌0.6/1 kV ‌. It is widely used in: ‌Power Distribution Systems ‌ – Suitable for fixed installations in buildings, industrial plants, and infrastructure projects, delivering reliable power transmission in low-voltage networks. Fire Safety Critical Areas ‌ – The ‌"N" (fire-resistant) ‌

品質 銅導体およびXLPE絶縁を備えた0.6/1kV低電圧耐火ケーブル、防火用途向け 工場

銅導体およびXLPE絶縁を備えた0.6/1kV低電圧耐火ケーブル、防火用途向け

Low Voltage Fire Rated Cable 0.6/1kV CU/XLPE/PE YJY N2X2Y This fire-resistant cable is designed for low-voltage power distribution systems where fire safety is critical, rated for 0.6/1kV applications. Applications Suitable for installation in cable ducts, underground applications, and exposed installations in various industrial and commercial environments. Construction Details Conductor: Class 1/Class 2 stranded copper conductor Refractory layer: Single-sided gold mica tape

品質 鉄鋼テープ 装甲式電源ケーブル CU/XLPE/STA/PVC 工業鉄道地下用 中圧 工場

鉄鋼テープ 装甲式電源ケーブル CU/XLPE/STA/PVC 工業鉄道地下用 中圧

Steel Tape Armored Power Cable CU/XLPE/STA/PVC Medium Voltage for Industrial Railway Underground Applications These cables are used for electricity supply in medium voltage installation system, they are suitable for installation in indoors and outdoors, in cable ducts, underground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage. Construction Copper Core: Provides superior conductivity and durability

前回
ページ 7 の 25
次へ