logo
見つかりました 387 のための製品 "

pvc power cable

"
品質 630mm2 高電圧電源ケーブル,XLPE隔熱と電源転送のための銅スクリーン 工場

630mm2 高電圧電源ケーブル,XLPE隔熱と電源転送のための銅スクリーン

630mm2 High Voltage Power Cable with XLPE Insulation and Copper Screened for Power Transmission APPLICATION 630mm² high-voltage power cable with XLPE insulation and copper screened is primarily used for transmitting electrical power in high-voltage applications. Its cross-linked polyethylene (XLPE) insulation provides excellent dielectric strength and thermal stability, while the copper screen offers effective electromagnetic shielding and ensures reliable grounding. This

品質 IEC 60502-2 XLPE 断熱型アルミニウム 装甲型 3X300mm 3X150mm 耐火電源ケーブル 工場

IEC 60502-2 XLPE 断熱型アルミニウム 装甲型 3X300mm 3X150mm 耐火電源ケーブル

IEC 60502-2 XLPE Insulated Aluminium Armoured 3X300mm 3X150mm Flame Retardant Power Cable Applications The cables arewidely used in places such as wind farms and solar power stations to meet the power transmission needs of these places ‌ Main Technical Properties 1. DC resistance of conductor at 20°C : not exceed ing 0.1 Ω/km; 2. 4h Power Frequency Voltage Test (4U₀) : No breakdown occurred; 3. 50Hz AC Withstand Voltage Test: 65 kV for 30 min ; No breakdown occurred; 4.

品質 ASTM標準上空配送線用ABC電源ケーブル15kV35kV 工場

ASTM標準上空配送線用ABC電源ケーブル15kV35kV

ASTM Standard Aerial Bundled ABC Power Cable 15kV 35kV For Overhead Distribution Line APPLICATION Screened MV ABC cables are specialized power transmission solutions combining medium-voltage (MV) capabilities with the structural advantages of Aerial Bunch Cables (ABC). Their applications include: Medium-Voltage Distribution Networks Aerial Power Infrastructure ‌Industrial Power Supply ‌ ‌Renewable Energy Projects ‌ CONSTRUCTION Conductor: Circular Compacted Stranded H68

品質 110kV配電網 高圧電源ケーブル CU/XLPE/CWS/STA/PE 工場

110kV配電網 高圧電源ケーブル CU/XLPE/CWS/STA/PE

110kV Distribution Networks High Voltage Power Cable CU/XLPE/CWS/STA/PE APPLICATION This cable is designed for ‌high-reliability, high-safety power transmission‌ in complex environments, particularly for fixed installations in demanding conditions. CONSTRUCTION Conductor:Co pper conductor Conductor shield: Semi-conductive shield Insulation: Cross-Linked Polyethylene(XLPE) Insulation shield: Semi-conductive shield Metal shielding layer: Copper Wire Binder tape: Non-woven

品質 6kv 10kV XLPE 絶縁電源ケーブル 3コア アルミワイヤ 装甲 N2XSRY 工場

6kv 10kV XLPE 絶縁電源ケーブル 3コア アルミワイヤ 装甲 N2XSRY

6/10kV XLPE Insulated Power Cable 3 Core aluminium wire armoured N2XSRY Application XLPE(Cross linked polyethylene) cable constitutes the best cable for transmission and distribution lines because of its excellent electrical and physical properties. These cables has the advantage of simplicity in construction, lightness in weight; convenience in application besides its excellent electrical, thermal, mechanical and anti-chemical corrosion properties. It can also be laid with

品質 XLPE 中圧電源ケーブル アルミ合金電導体付き 工場

XLPE 中圧電源ケーブル アルミ合金電導体付き

Aluminium Alloy Conductor XLPE Insulated Power Cable Copper Wire Shield XLPE/PVC/STA Medium Voltage Application Used for tall building, Hospital, Theatre, Power station, Metro Tunnel or Petrochemical Industry or other special place required for low smoke , zero halogen clean and safe cable. Construction Conductor Conductor Shield Insulation Metal Shield Layer Filler Binder Tape Armouring Outer sheath Laying Method Pipe laying, trench laying, tunnel laying, vertical shaft and

品質 0.6Kv 1kv XLPE アルミ合金 ABC 電源ケーブル 装甲式または装甲式地下ケーブル 工場

0.6Kv 1kv XLPE アルミ合金 ABC 電源ケーブル 装甲式または装甲式地下ケーブル

Overhead ABC Cable 0.6/1kv XLPE Aluminum Alloy Power Cable Underground Armored/Unarmored Cable Applicatiom Widely used in the energy field (power stations, nuclear power posts, urban and rural power grids, coal mines, petrochemicals, etc.), transportation field (civil aviation, nuclear power plant) network, coal mine, petrochemicals, etc.), transportation field (civil aviation airports, railroads and urban rail transportation, ships and transportation field (civil aviation,

品質 1コア 3コア スチールワイヤー 装甲ケーブル 6-35kV MV 中圧電源ケーブル 工場

1コア 3コア スチールワイヤー 装甲ケーブル 6-35kV MV 中圧電源ケーブル

Medium Voltage 6-35kV Armoured Electrical Cable 1 Core 3 Core Application Medium voltage Armoured power cable for static application in ground, within and outside facilities, outdoor, in cable canals,in water, in conditions where cables are not exposed to heavier mechanical stress and tensile strain.. Construction Conductor:Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation:XLPE PE or PVC Filler: Non-hygroscopic material Inner sheath: PVC

品質 IEC60502-1 標準低電圧ケーブル CU XLPE PVC STA 装甲電源ケーブル 工場

IEC60502-1 標準低電圧ケーブル CU XLPE PVC STA 装甲電源ケーブル

IEC60502-1 Standard Low Voltage Cable CU/XLPE/PVC/STA Armoured Application For laying indoors, in tunnel, cable trench, or direct in ground, the cable can bear external mechanical forces but unable to bear large pulling force. Construction Conductor:Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation:XLPE Filler: Non-hygroscopic material Binder tape:: Non-hygroscopic material Sheath PVC Characteristics Test Voltage: 3.5kV 5min No Breakdown The

前回
ページ 9 の 43
次へ