pvc power cable
"
630mm2 Υψηλής τάσης καλώδιο ηλεκτρικής ενέργειας με μόνωση XLPE και προστασία από χαλκό για τη μετάδοση ισχύος
630mm2 High Voltage Power Cable with XLPE Insulation and Copper Screened for Power Transmission APPLICATION 630mm² high-voltage power cable with XLPE insulation and copper screened is primarily used for transmitting electrical power in high-voltage applications. Its cross-linked polyethylene (XLPE) insulation provides excellent dielectric strength and thermal stability, while the copper screen offers effective electromagnetic shielding and ensures reliable grounding. This
IEC 60502-2 XLPE Απομονωμένο αλουμινένιο θωρακισμένο καλώδιο ισχύος 3X300mm 3X150mm με ανθεκτικό στη φλόγα
IEC 60502-2 XLPE Insulated Aluminium Armoured 3X300mm 3X150mm Flame Retardant Power Cable Applications The cables arewidely used in places such as wind farms and solar power stations to meet the power transmission needs of these places Main Technical Properties 1. DC resistance of conductor at 20°C : not exceed ing 0.1 Ω/km; 2. 4h Power Frequency Voltage Test (4U₀) : No breakdown occurred; 3. 50Hz AC Withstand Voltage Test: 65 kV for 30 min ; No breakdown occurred; 4.
Αεροπορικό καλώδιο ηλεκτρικής ενέργειας ABC 15kV 35kV για αεροδιανομή
ASTM Standard Aerial Bundled ABC Power Cable 15kV 35kV For Overhead Distribution Line APPLICATION Screened MV ABC cables are specialized power transmission solutions combining medium-voltage (MV) capabilities with the structural advantages of Aerial Bunch Cables (ABC). Their applications include: Medium-Voltage Distribution Networks Aerial Power Infrastructure Industrial Power Supply Renewable Energy Projects CONSTRUCTION Conductor: Circular Compacted Stranded H68
Δίκτυα διανομής 110 kV Υψηλής τάσης καλώδιο ισχύος CU/XLPE/CWS/STA/PE
110kV Distribution Networks High Voltage Power Cable CU/XLPE/CWS/STA/PE APPLICATION This cable is designed for high-reliability, high-safety power transmission in complex environments, particularly for fixed installations in demanding conditions. CONSTRUCTION Conductor:Co pper conductor Conductor shield: Semi-conductive shield Insulation: Cross-Linked Polyethylene(XLPE) Insulation shield: Semi-conductive shield Metal shielding layer: Copper Wire Binder tape: Non-woven
6kv 10kV XLPE Απομονωμένο καλώδιο ηλεκτρικής ενέργειας 3 πυρήνες Αλουμινίου
6/10kV XLPE Insulated Power Cable 3 Core aluminium wire armoured N2XSRY Application XLPE(Cross linked polyethylene) cable constitutes the best cable for transmission and distribution lines because of its excellent electrical and physical properties. These cables has the advantage of simplicity in construction, lightness in weight; convenience in application besides its excellent electrical, thermal, mechanical and anti-chemical corrosion properties. It can also be laid with
XLPE μονωμένα καλώδια ηλεκτρικής ενέργειας μεσαίας τάσης με αλουμινένιο αλουμινένιο
Aluminium Alloy Conductor XLPE Insulated Power Cable Copper Wire Shield XLPE/PVC/STA Medium Voltage Application Used for tall building, Hospital, Theatre, Power station, Metro Tunnel or Petrochemical Industry or other special place required for low smoke , zero halogen clean and safe cable. Construction Conductor Conductor Shield Insulation Metal Shield Layer Filler Binder Tape Armouring Outer sheath Laying Method Pipe laying, trench laying, tunnel laying, vertical shaft and
0.6Kv 1kv XLPE Αλουμινίου Σύνθεσης ABC Δυναμικό Καλώδιο Υπογείου Τυχερό ή Μη Τυχερό Καλώδιο
Overhead ABC Cable 0.6/1kv XLPE Aluminum Alloy Power Cable Underground Armored/Unarmored Cable Applicatiom Widely used in the energy field (power stations, nuclear power posts, urban and rural power grids, coal mines, petrochemicals, etc.), transportation field (civil aviation, nuclear power plant) network, coal mine, petrochemicals, etc.), transportation field (civil aviation airports, railroads and urban rail transportation, ships and transportation field (civil aviation,
1 πυρήνας 3 πυρήνες Ατσάλινο καλώδιο θωρακισμένο 6-35kV MV καλώδιο ισχύος μέσης τάσης
Medium Voltage 6-35kV Armoured Electrical Cable 1 Core 3 Core Application Medium voltage Armoured power cable for static application in ground, within and outside facilities, outdoor, in cable canals,in water, in conditions where cables are not exposed to heavier mechanical stress and tensile strain.. Construction Conductor:Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation:XLPE PE or PVC Filler: Non-hygroscopic material Inner sheath: PVC
Τύπος IEC60502-1 Καλώδιο χαμηλής τάσης CU XLPE PVC STA Καλώδιο θωρακισμένης ισχύος
IEC60502-1 Standard Low Voltage Cable CU/XLPE/PVC/STA Armoured Application For laying indoors, in tunnel, cable trench, or direct in ground, the cable can bear external mechanical forces but unable to bear large pulling force. Construction Conductor:Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation:XLPE Filler: Non-hygroscopic material Binder tape:: Non-hygroscopic material Sheath PVC Characteristics Test Voltage: 3.5kV 5min No Breakdown The