logo
見つかりました 230 のための製品 "

aluminum conductor cable

"
品質 シングルコア低電圧ケーブルワイヤ 0.6KV 1kV PVC 断熱鋼テープ 装甲 STA 工場

シングルコア低電圧ケーブルワイヤ 0.6KV 1kV PVC 断熱鋼テープ 装甲 STA

Single Core Low Voltage Cable 0.6/1kV PVC insulated Steel tape Armored STA Application The cables are mainly used in energy networks with sudden load change residental or industrial areas. Can be laid outdoors, under grounds and in areas where sudden mechanical stress are expected Construction Conductor:Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation:PVC Filler: Non-hygroscopic material Inner sheath: PVC Outer Sheath PVC Technical data The

品質 110kV単核高電圧ケーブル 1000mm2 600mm2 地下送電ケーブル 工場

110kV単核高電圧ケーブル 1000mm2 600mm2 地下送電ケーブル

110kV Single Core High Voltage Cable 1000 mm2 600 mm2 3130 mm Underground Transmission Cable Application ‌Power Transmission Systems‌: Primarily used in large-scale power grids to transmit electricity between power stations, substations, and urban distribution networks, especially for voltages above 110kV‌. ‌Electric Vehicles (EVs)‌: Transmit high-voltage electricity (up to 1500V) from batteries to motors, inverters, and charging systems, while also relaying signals to

品質 2X12 AWG 2コアケーブル 工場

2X12 AWG 2コアケーブル

Tinned Copper Flexible Stranded Electrical Wire 2X12 AWG 2 Core Cable APPLICATION ‌Industrial equipment‌ requiring high flexibility and durability, such as robotic arms and automated machinery. ‌Power distribution systems‌ where corrosion resistance is critical, especially in marine or humid environments‌ ‌Renewable energy installations‌ (e.g., solar panel arrays) due to its excellent conductivity and tinned oxidation resistance. CONSTRUCTION AND SEPCIFICATION Conductor

品質 地下鉄鋼鉄線 装甲ケーブル XLPE 侮辱 NYR2Y NAYR2Y 工場

地下鉄鋼鉄線 装甲ケーブル XLPE 侮辱 NYR2Y NAYR2Y

Underground Galvanized Steel Wire Armoured Electrical Cable XLPE Insulted NYR2Y NAYR2Y Application Used for electricity supply in low voltage installation system, they are suitable for installation in indoors and outdoors, in cable ducts, underground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage Construction Conductor:Circular, solid, compacted or sector shaped stranded Copper or aluminum

品質 IEC 60502 STA 装甲式電気ケーブル 地下使用のための3コア 工場

IEC 60502 STA 装甲式電気ケーブル 地下使用のための3コア

IEC 60502 STA Armoured Electrical Cable Three Core for underground use Application PVC power cable for static outdoor application (with protection against direct UV-irradiation), in ground, in water, within facilities, in cable canals, in concrete, in conditions where heavier mechanical loads and specially tensile strains, are not expected. Used in electric power plants, transformer stations, industrial plants, metropolitan networks and in other electric plants, same as for

品質 0.6KV 1kV PVC 断熱型 PVC 覆い電線 3コア オーダーメイド長さ 工場

0.6KV 1kV PVC 断熱型 PVC 覆い電線 3コア オーダーメイド長さ

0.6/1kV Three Core PVC Insulated Power Cable PVC Sheathed Electrical Cable Application Internal wring or external interconnection of electronic equipment. Construction Conductor:Circular, solid, compacted or sector shaped stranded copper or aluminum Insulation:PVC Filler: Non-hygroscopic material Inner sheath:PVC Outer sheath:PVC Characteristics Test Voltage: 3.5kV 5min No Breakdown The ambient temperature for installation: ≥0℃. Maximum conductor temperature in normal

品質 銅ワイヤスクリーン 低電圧ケーブル 単核 0.6/1kV PVC隔離ケーブル 工場

銅ワイヤスクリーン 低電圧ケーブル 単核 0.6/1kV PVC隔離ケーブル

Copper Wire Screen Low Voltage Cable Single Core 0.6/1kV PVC Insulated Cable APPLICATION Copper-shielded low-voltage cables are widely used in environments requiring reliable power transmission with electromagnetic interference (EMI) protection CONSTRUCTION Conductor:Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation:XLPE Filler: Non-hygroscopic material Screen: Copper Wire Binder tape:: Non-hygroscopic material Sheath PVC Characteristics Test

品質 CU XLPE PVC低電圧電源ケーブル 銅線 シールドケーブル 0.6/1kV 工場

CU XLPE PVC低電圧電源ケーブル 銅線 シールドケーブル 0.6/1kV

CU/XLPE/PVC Low Voltage Cable Copper Wire Shielded Cable 0.6/1kV Application The cable could be laying indoors, in tunnel, cable trench, or direct in ground, they can bear external mechanical forces, but unable to bear large pulling force. Construction Conductor:Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation:XLPE Filler: Non-hygroscopic material Screen: Copper Wire Binder tape:: Non-hygroscopic material Sheath PVC Characteristics Test

品質 N2XBY NA2XBY 3コア低電圧ケーブル 0.6/1kV 0.5~800MM2 lVケーブル 工場

N2XBY NA2XBY 3コア低電圧ケーブル 0.6/1kV 0.5~800MM2 lVケーブル

N2XBY NA2XBY Low Voltage Cable 3 Core 0.6/1kV 0.5 ~ 800MM2 Construction Conductor: Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation: XLPE Filler: non-hygroscopic material Binder tape: non-hygroscopic material Sheath: PVC Characteristics Test Voltage: 3.5kV 5min No Breakdown The ambient temperature for installation: ≥0℃. Maximum conductor temperature in normal operation:≤90℃. Max operating temperature of con. When cable short-circuited(5s