logo
見つかりました 230 のための製品 "

aluminum conductor cable

"
品質 電源伝送用の防火装甲電源ケーブル CU/XLPE/AWA/SWA/PE 工場

電源伝送用の防火装甲電源ケーブル CU/XLPE/AWA/SWA/PE

Flame Retardant Armoured Power Cable CU/XLPE/AWA/SWA/PE for Power Transmission APPLICATION Flame Retardant Armoured Power Cable CU/XLPE/AWA/SWA/PE for Power Transmission‌ is a high-performance cable designed for safe and reliable power transmission in demanding environments CONSTRUCTION Conductor: Class 1/ Class 2 stranded Copper conductor Refractory layer: Single sided gold mica tape Insulation: XLPE Filler ( options ): Polypropylene mesh tear rope or flame-retardant filling

品質 6kv 10kV XLPE 絶縁電源ケーブル 3コア アルミワイヤ 装甲 N2XSRY 工場

6kv 10kV XLPE 絶縁電源ケーブル 3コア アルミワイヤ 装甲 N2XSRY

6/10kV XLPE Insulated Power Cable 3 Core aluminium wire armoured N2XSRY Application XLPE(Cross linked polyethylene) cable constitutes the best cable for transmission and distribution lines because of its excellent electrical and physical properties. These cables has the advantage of simplicity in construction, lightness in weight; convenience in application besides its excellent electrical, thermal, mechanical and anti-chemical corrosion properties. It can also be laid with

品質 600V 1000V XLPE 断熱電源ケーブル PVC / LSZH ジャケット 地下空用 工場

600V 1000V XLPE 断熱電源ケーブル PVC / LSZH ジャケット 地下空用

0.6/1kV XLPE Insulated Power Cable With PVC / LSZH Jacket Application The XLPE insulated power cable is widely used in various applications, such as underground installation, overhead installation, and indoor installation. It is used in power transmission and distribution systems, as well as in industrial and mining applications. The cable is suitable for use in areas where there is a need for reliable and safe electrical supply. Construction Conductor:Circular, solid,

品質 CU XLPE STA PVC MV 地下ケーブル IEC 標準 18/30kV 中圧線 工場

CU XLPE STA PVC MV 地下ケーブル IEC 標準 18/30kV 中圧線

CU/XLPE/SWA/PVC Medium Voltage Cable 18/30kV IEC Standard Underground Cable Application The cables are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground as well as for installation on cable trays for industries, switchboards and power stations Construction Conductor: Class 2 Aluminium/Copper circular, stranded Conductor Screen: Semi-conductive XLPE (Cross-Linked Polyethylene) Insulation : XLPE (Cross-Linked Polyethyle

品質 11KV 22KV 33KV 中電圧ケーブル XLPE/ビニール/Cu 3芯 工場

11KV 22KV 33KV 中電圧ケーブル XLPE/ビニール/Cu 3芯

11KV 22KV 33KV Medium Voltage Cable XLPE/Vinyl/Cu 3 Core Application 1. Industrial power distribution: factory power supply, mining and petrochemical industry2. Construction and infrastructure: commercial buildings, subways and tunnels3. Energy and power transmission: substation connection, new energy projects4. Underground and submarine laying: underground cable engineering, submarine cable Construction Conductor: Circular compacted stranded Copper or aluminium Conductor

品質 Tinned Copper Wire Shield instrument Cable 2X10AWG 2X12AWG 2X16AWG 工場

Tinned Copper Wire Shield instrument Cable 2X10AWG 2X12AWG 2X16AWG

Tinned Copper Wire Shield instrument Cable 2X10AWG 2X12AWG 2X16AWG APPLICATION Telecommunications Networking Infrastructure Industrial Automation Audio-Visual Systems Transportation CONSTRUCTION AND SEPCIFICATION Conductor Material: Tinned Copper (Flexible Stranded) Number of Conductors: 102 strands Insulation: PVC Strand Diameter: 0.20 mm Shielding Layer: Polyester Tape + Aluminum Foil Flat Cable Specification: 10 strands × 0.20 mm Braid Layer: 128 strands × 0.10 mm FACTORY

品質 630mm2 高電圧電源ケーブル,XLPE隔熱と電源転送のための銅スクリーン 工場

630mm2 高電圧電源ケーブル,XLPE隔熱と電源転送のための銅スクリーン

630mm2 High Voltage Power Cable with XLPE Insulation and Copper Screened for Power Transmission APPLICATION 630mm² high-voltage power cable with XLPE insulation and copper screened is primarily used for transmitting electrical power in high-voltage applications. Its cross-linked polyethylene (XLPE) insulation provides excellent dielectric strength and thermal stability, while the copper screen offers effective electromagnetic shielding and ensures reliable grounding. This

品質 銅テープで遮断された制御ケーブル CU/PVC/PVC 450/750V 銅製の防火ケーブル 工場

銅テープで遮断された制御ケーブル CU/PVC/PVC 450/750V 銅製の防火ケーブル

Copper-tape Screened Control Cable CU/PVC/PVC 450/750V Copper Fire Rated Cable APPLICATION 450/750V PVC Insulation Screened Control Cable is widely used for in control, monitoring and protection circuits of rated voltage 450/750V and below. Fire resistance, no halogen, flame retardant and other feathers are available. CONSTRUCTION 1) Conductor: solid / stranded copper 2) Insulation: PVC 3) Screen: braided copper wire, copper tape or aluminum plastic composite tape 4)

品質 マルチコアLSZH低煙ゼロハロゲンケーブルXLPE鋼鉄ワイヤ装甲 工場

マルチコアLSZH低煙ゼロハロゲンケーブルXLPE鋼鉄ワイヤ装甲

Multi Core Low Smoke Zero Halogen Cable XLPE Steel Wire Armoured Application For fixed installation of the transmission and distribution systems, tunnels and pipelines and other occasions .For situation not suppose to bear the external mechanical force. Constructions Conductor: Plain circular stranded copper conductor, conform to IEC 60228 class 2 Insulation: XLPE Amour: Steel Wire armour Core Conductor :annealed copper (stranded core) Popular sizes: 2~5 core x1.5~630mm²