aluminum conductor cable
"
단일 코어 저전압 케이블 와이어 0.6KV 1kV PVC 단열 철강 테이프 장갑 STA
Single Core Low Voltage Cable 0.6/1kV PVC insulated Steel tape Armored STA Application The cables are mainly used in energy networks with sudden load change residental or industrial areas. Can be laid outdoors, under grounds and in areas where sudden mechanical stress are expected Construction Conductor:Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation:PVC Filler: Non-hygroscopic material Inner sheath: PVC Outer Sheath PVC Technical data The
110kV 단일 코어 고전압 케이블 1000mm2 600mm2 지하 전송 케이블
110kV Single Core High Voltage Cable 1000 mm2 600 mm2 3130 mm Underground Transmission Cable Application Power Transmission Systems: Primarily used in large-scale power grids to transmit electricity between power stations, substations, and urban distribution networks, especially for voltages above 110kV. Electric Vehicles (EVs): Transmit high-voltage electricity (up to 1500V) from batteries to motors, inverters, and charging systems, while also relaying signals to
주석 도금 연동 연선 전선 2X12 AWG 2심 케이블
Tinned Copper Flexible Stranded Electrical Wire 2X12 AWG 2 Core Cable APPLICATION Industrial equipment requiring high flexibility and durability, such as robotic arms and automated machinery. Power distribution systems where corrosion resistance is critical, especially in marine or humid environments Renewable energy installations (e.g., solar panel arrays) due to its excellent conductivity and tinned oxidation resistance. CONSTRUCTION AND SEPCIFICATION Conductor
지하 젤리화 된 철선 장갑 케이블 XLPE 경멸 NYR2Y NAYR2Y
Underground Galvanized Steel Wire Armoured Electrical Cable XLPE Insulted NYR2Y NAYR2Y Application Used for electricity supply in low voltage installation system, they are suitable for installation in indoors and outdoors, in cable ducts, underground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage Construction Conductor:Circular, solid, compacted or sector shaped stranded Copper or aluminum
IEC 60502 STA 장갑 전기 케이블 지하 사용용 3 코어
IEC 60502 STA Armoured Electrical Cable Three Core for underground use Application PVC power cable for static outdoor application (with protection against direct UV-irradiation), in ground, in water, within facilities, in cable canals, in concrete, in conditions where heavier mechanical loads and specially tensile strains, are not expected. Used in electric power plants, transformer stations, industrial plants, metropolitan networks and in other electric plants, same as for
0.6KV 1kV PVC 단열 PVC 껍질 전기 케이블 세 개의 코어 사용자 정의 길이
0.6/1kV Three Core PVC Insulated Power Cable PVC Sheathed Electrical Cable Application Internal wring or external interconnection of electronic equipment. Construction Conductor:Circular, solid, compacted or sector shaped stranded copper or aluminum Insulation:PVC Filler: Non-hygroscopic material Inner sheath:PVC Outer sheath:PVC Characteristics Test Voltage: 3.5kV 5min No Breakdown The ambient temperature for installation: ≥0℃. Maximum conductor temperature in normal
구리 와이어 스크린 저전압 케이블 단일 코어 0.6/1kV PVC 단열 케이블
Copper Wire Screen Low Voltage Cable Single Core 0.6/1kV PVC Insulated Cable APPLICATION Copper-shielded low-voltage cables are widely used in environments requiring reliable power transmission with electromagnetic interference (EMI) protection CONSTRUCTION Conductor:Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation:XLPE Filler: Non-hygroscopic material Screen: Copper Wire Binder tape:: Non-hygroscopic material Sheath PVC Characteristics Test
CU XLPE PVC 저전압 전력 케이블 구리 와이어 보호 케이블 0.6/1kV
CU/XLPE/PVC Low Voltage Cable Copper Wire Shielded Cable 0.6/1kV Application The cable could be laying indoors, in tunnel, cable trench, or direct in ground, they can bear external mechanical forces, but unable to bear large pulling force. Construction Conductor:Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation:XLPE Filler: Non-hygroscopic material Screen: Copper Wire Binder tape:: Non-hygroscopic material Sheath PVC Characteristics Test
N2XBY NA2XBY 3 코어 저전압 케이블 0.6/1kV 0.5~800MM2 lV 케이블
N2XBY NA2XBY Low Voltage Cable 3 Core 0.6/1kV 0.5 ~ 800MM2 Construction Conductor: Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation: XLPE Filler: non-hygroscopic material Binder tape: non-hygroscopic material Sheath: PVC Characteristics Test Voltage: 3.5kV 5min No Breakdown The ambient temperature for installation: ≥0℃. Maximum conductor temperature in normal operation:≤90℃. Max operating temperature of con. When cable short-circuited(5s