logo
Ditemukan 379 produk untuk "

xlpe insulated cable

"
Kualitas 66KV 69kv 110kv 132KV HV Kabel XLPE Isolasi Kabel Tegangan Tinggi 1000MM2 1500MM2 2500M2 Pabrik

66KV 69kv 110kv 132KV HV Kabel XLPE Isolasi Kabel Tegangan Tinggi 1000MM2 1500MM2 2500M2

66KV 69kv 110kv 132KV HV Cable XLPE Insulation High Voltage Cable 1000MM2 1500MM2 2500M2 APPLICATION For laying indoors,in tunnel cable trench,well or direct in ground,able to bear external mechanical forces and certain pulling force. CONSTRUCTION Conductor: Stranded circular or segmental (Milliken) compacted copper conductor Conductor shield: Semi-conductive shield Insulation: Cross-Linked Polyethylene(XLPE) Insulation shield: Semi-conductive shield Metal shielding layer:

Kualitas 110kV XLPE Kabel Tembaga Terisolasi 630mm2 Dengan Lapisan Aluminium Bergelombang Tersald Pabrik

110kV XLPE Kabel Tembaga Terisolasi 630mm2 Dengan Lapisan Aluminium Bergelombang Tersald

Dirancang untuk transmisi bawah tanah 110kV, kabel tembaga 630mm² berinsulasi XLPE ini dilengkapi dengan selubung aluminium bergelombang yang dilas untuk penguburan langsung yang 100% kedap air. Sesuai dengan IEC 60840, ideal untuk gardu induk, jaringan bawah tanah kota, dan industri berat. FAT pihak ketiga didukung.

Kualitas ACWU90 Aluminium Conductor Cable # 8 AWG THRU 750 kcmil XLPE/aluminium Armored/PVC Cable Pabrik

ACWU90 Aluminium Conductor Cable # 8 AWG THRU 750 kcmil XLPE/aluminium Armored/PVC Cable

ACWU90 Aluminium Conductor Cable #8 AWG THRU 750 kcmil XLPE/aluminium Armoured /PVC Cable APPLICATION Suitable for urban underground power grids, power station outgoing lines, internal power supply lines of industrial and mining enterprises, etc. CONSTRUCTION Conductor: 8 AWG. thru 750 kcmil aluminum (8000 series aluminum) compact class “B” strand Insulation: Cross-linked Polyethylene (XLPE) Type RW90 Bonding Conductor (Ground): One (1) bare stranded aluminum (ACM) conductor

Kualitas AWA Aluminium Wire Armored Flame-retardant Power Cable CU/XLPE/CTS/AWA Pabrik

AWA Aluminium Wire Armored Flame-retardant Power Cable CU/XLPE/CTS/AWA

AWA Aluminium Wire Armored Flame-retardant Power Cable CU/XLPE/CTS/AWA APPLICATION Industrial Power Networks‌: Suitable for factories, mining sites, and heavy machinery due to its armored design (AWA) and flame-retardant properties‌ Commercial Buildings‌: Ensures safe power transmission in shopping malls, hospitals, and high-rises, where fire safety is critical‌ Harsh Environments‌: Resists physical damage and moisture, making it ideal for outdoor installations or areas with

Kualitas Kabel Berlapis Baja SWA 1.5mm2 3.6-35kV AL/XLPE/CWS/CTS/SWA/PVC untuk Distribusi Daya Pabrik

Kabel Berlapis Baja SWA 1.5mm2 3.6-35kV AL/XLPE/CWS/CTS/SWA/PVC untuk Distribusi Daya

1.5mm2 SWA Armoured Cable 3.6-35kV AL/XLPE/CWS/CTS/SWA/PVC for Power Distribution Application The core application of this 1.5mm² SWA Armoured Cable 3.6-35kV AL/XLPE/CWS/CTS/SWA/PVC is ‌medium-voltage power underground direct burial, conduit installation, or fixed wiring‌. It is particularly suitable for occasions requiring ‌mechanical protection and tensile strength‌, such as ‌power distribution networks, industrial facilities, or infrastructure construction‌. Construction

Kualitas OEM 1 Core PVC Terisolasi Kabel Listrik Aluminium Konduktor 120mm 150mm Pabrik

OEM 1 Core PVC Terisolasi Kabel Listrik Aluminium Konduktor 120mm 150mm

Single Core PVC Insulated Power Cable Aluminium Conductor 120mm 150mm Description This single-core electric cable is designed for efficient and reliable power transmission in various industrial, commercial, and residential applications. It features a high-quality aluminum (AL) or copper (CU) conductor, ensuring excellent electrical conductivity and durability. The cable is insulated and sheathed with polyvinyl chloride (PVC), providing superior protection against moisture,

Kualitas Single Core HV High Voltage Power Cable  2XS(FL)2Y CU/XLPE/CWS/STA/PVC Pabrik

Single Core HV High Voltage Power Cable 2XS(FL)2Y CU/XLPE/CWS/STA/PVC

Single Core HV High Voltage Power Cable 2XS(FL)2Y CU/XLPE/CWS/STA/PVC APPLICATION Urban underground networks‌ (e.g., substation connections, industrial power distribution)‌ Harsh environments‌ requiring robust mechanical and chemical protection‌ CONSTRUCTION Conductor: Stranded circular or segmental (Milliken) compacted copper conductor Conductor shield: Semi-conductive shield Insulation: Cross-Linked Polyethylene(XLPE) Insulation shield: Semi-conductive shield Metal

Kualitas Kabel LSZH Perlindungan Kebakaran Tiga Inti MV 8.7/15kV XLPE Berinsulasi Pita Baja Lapis Baja Kabel Berselubung PVC Pabrik

Kabel LSZH Perlindungan Kebakaran Tiga Inti MV 8.7/15kV XLPE Berinsulasi Pita Baja Lapis Baja Kabel Berselubung PVC

Fire Protection LSZH Cable Three Core MV 8.7/15kV XLPE Insulated Steel Tape Armored PVC Sheathed Cable Product Overview Fire Rated Low Voltage Wire with 3 Core 1.5-400mm² is engineered to maintain circuit integrity during fire conditions, ensuring continuous power supply for critical emergency systems. Applications Suitable for power supply lines with flame retardant requirements, such as urban underground power grids, power station outgoing lines, and internal power lines of

Kualitas Kabel lapis baja bersertifikat CE AL/XLPE/STA/SWA/PVC 240mm2 Kabel Pabrik

Kabel lapis baja bersertifikat CE AL/XLPE/STA/SWA/PVC 240mm2 Kabel

CE Certified Aluminium Armoured Cable AL/XLPE/STA/SWA/PVC 240mm2 Cable Constuction ✔ XLPE Insulation (Cross-linked polyethylene) - Superior thermal stability (90°C rated) ✔ PVC Outer Sheath - UV resistant formulation (custom LSZH/Fire-resistant options availabl e)✔ Dual Certification - Compliant with IEC 60502-1 & GB/T 12706.1✔ Optional Armoring - Steel tape (YJLV22) or wire (YJLV32) for mechanical protection Advantages: ✔ Lower Power Loss – XLPE insulation ensures higher