ACWU90 Aluminium Conductor Cable # 8 AWG THRU 750 kcmil XLPE/aluminium Armored/PVC Cable
| Conductor: | 8000 Paduan Aluminium | Insulation: | PVC |
| Voltage Rating: | 600/1000V | Outer Sheath Colour: | Hitam |
| Temperature: | Tetap -40 ° C hingga +80 ° C | AWG: | 8# |
| High Light: | kabel konduktor aluminium dengan isolasi XLPE,kabel PVC berpelindung untuk instalasi listrik,kabel aluminium AWG dengan pelindung |
||
ACWU90 Aluminium Conductor Cable # 8 AWG THRU 750 kcmil XLPE/aluminium Armored/PVC Cable
Aplikasi
Cocok untuk jaringan listrik bawah tanah perkotaan, saluran keluar pembangkit listrik, saluran pasokan listrik internal perusahaan industri dan pertambangan, dll.
Konstruksi
- Konduktor: 8 AWG. melalui 750 kcmil aluminium (aluminium seri 8000) kelas kompak
- Isolasi: Polyethylene Cross-linked (XLPE) tipe RW90
- Konduktor ikatan (Bumi): Satu (1) konduktor aluminium bergelombang (ACM)
- Armor:: Aluminium Interlocked Armor (AIA)
- Jaket: rendah gas asam, tahan api, kelembaban dan tahan sinar matahari Polyvinyl Chloride (PVC),

CHARACTeroris
- Beroperasi di lingkungan basah dan kering dengan suhu terus menerus 90 °C
- Ketahanan yang lebih baik terhadap penghancuran, minyak, dan bahan kimia yang keras (misalnya, asam, pelarut)
- Dirancang untuk memperpanjang umur layanan di bawah kondisi yang menuntut, mengurangi frekuensi penggantian
- Alternatif yang hemat biaya terhadap instalasi di saluranAku tidak tahu.
- Memenuhi uji lentur dingin dan benturan pada (-40°C)
Spesifikasi
| Tidak ada Kondisi. |
Kondisi. Ukuran |
Tanah Ukuran kawat |
MIN.AVG. Isolasi |
Nominal diameter (OVER) | NET | Kekuatan | ||||||
| (AWG/ kcmil) |
(AWG /kcmil) |
Ketebalan | Inti yang diputar | Perisai | Kabel | Berat badan | AT 90°C | |||||
| Inch | mm | Inch | mm | Inch | mm | Inch | mm | KG/KM | ||||
| 3 | 8 | 8 | 0.045 | 1.14 | 0.533 | 13.5 | 0.783 | 19.89 | 0.870 | 22.10 | 422 | 45 |
| 3 | 6 | 8 | 0.045 | 1.14 | 0.565 | 14.4 | 0.845 | 21.46 | 0.932 | 23.67 | 498 | 55* |
| 3 | 4 | 6 | 0.045 | 1.14 | 0.675 | 17.1 | 0.925 | 23.50 | 1.012 | 25.70 | 619 | 75 |
| 3 | 3 | 6 | 0.045 | 1.14 | 0.744 | 18.9 | 0.994 | 25.25 | 1.081 | 27.46 | 690 | 85 |
| 3 | 2 | 6 | 0.045 | 1.14 | 0.785 | 19.9 | 1.070 | 27.18 | 1.157 | 29.39 | 794 | 100 |
| 3 | 1 | 4 | 0.055 | 1.40 | 0.902 | 22.9 | 1.152 | 29.26 | 1.239 | 31.47 | 951 | 115 |
| 3 | 1/00 | 4 | 0.055 | 1.40 | 1.107 | 28.1 | 1.357 | 34.47 | 1.314 | 33.38 | 1085 | 135 |
| 3 | 2/00 | 4 | 0.055 | 1.40 | 1.066 | 27.1 | 1.316 | 33.43 | 1.403 | 35.64 | 1246 | 150 |
| 3 | 3/00 | 4 | 0.055 | 1.40 | 1.170 | 29.7 | 1.420 | 36.07 | 1.507 | 38.28 | 1450 | 175 |
| 3 | 4/00 | 4 | 0.055 | 1.40 | 1.281 | 32.5 | 1.531 | 38.89 | 1.636 | 41.55 | 1697 | 205 |
| 3 | 250 | 2 | 0.065 | 1.65 | 1.391 | 35.3 | 1.641 | 41.68 | 1.771 | 44.98 | 2072 | 230 |
| 3 | 300 | 2 | 0.065 | 1.65 | 1.496 | 38.0 | 1.836 | 46.63 | 1.966 | 49.94 | 2378 | 260 |
| 3 | 350 | 2 | 0.065 | 1.65 | 1.593 | 40.5 | 1.903 | 48.34 | 2.000 | 50.80 | 2681 | 280 |
| 3 | 400 | 2 | 0.065 | 1.65 | 1.686 | 42.8 | 1.996 | 50.70 | 2.101 | 53.37 | 2946 | 305 |
| 3 | 500 | 1 | 0.065 | 1.65 | 1.852 | 47.0 | 2.152 | 54.66 | 2.280 | 57.91 | 3585 | 350 |
| 3 | 600 | 1 | 0.080 | 2.03 | 2.077 | 52.8 | 2.267 | 57.58 | 2.518 | 63.96 | 4286 | 385 |
| 3 | 750 | 1/00 | 0.080 | 2.03 | 2.329 | 59.2 | 2.639 | 67.03 | 2.770 | 70.36 | 5058 | 435 |
TANAMAN KAMI

Aplikasi

Kemasan

Mitra


FAQ
T. Apa kabel ACWU90 terbuat dari?
A. ACWU90 memiliki konduktor paduan aluminium, isolasi XLPE, armor aluminium yang terkoneksi, dan selubung PVC, memberikan daya tahan dan ketahanan korosi.
T. Apa aplikasi utama ACWU90?
A. Cocok untuk bangunan distribusi listrik, fasilitas industri, tambang, instalasi luar ruangan, dan pengeboran langsung, menawarkan alternatif yang hemat biaya untuk kabel tembaga.
Q. Apa rentang suhu ACWU90 tahan?
A. Beroperasi dengan andal dari -40°C sampai +90°C (basah/kering), membuatnya ideal untuk iklim ekstrim.
Q. Apakah ACWU90 tahan api?
A. Ya, memenuhi standar tahan api Kelas B, memastikan keamanan di lingkungan berbahaya.
Q. Dapatkah ACWU90 dipasang tanpa saluran?
A. Ya, armornya yang terkunci memungkinkan pemakaman langsung atau instalasi baki, menghilangkan biaya saluran.
Q. Bagaimana ACWU90 dibandingkan dengan kabel tembaga?
A. Ini menawarkan kinerja yang sama dengan biaya 30~50% lebih rendah, dengan berat yang lebih ringan dan ketahanan korosi yang lebih baik.
T. Apa tegangan peringkat ACWU90 mendukung?
A. Cocok untuk sistem 600V sampai 35kV, yang mencakup aplikasi tegangan rendah hingga menengah.
Q. Apakah ACWU90 tahan terhadap bahan kimia dan minyak?
A. Ya, lapisan PVC dan insulasi XLPE memberikan ketahanan yang sangat baik terhadap minyak, asam, dan pelarut.