xlpe insulated cable
"
66KV 69kv 110kv 132KV cavo HV XLPE isolamento cavo ad alta tensione 1000MM2 1500MM2 2500M2
66KV 69kv 110kv 132KV HV Cable XLPE Insulation High Voltage Cable 1000MM2 1500MM2 2500M2 APPLICATION For laying indoors,in tunnel cable trench,well or direct in ground,able to bear external mechanical forces and certain pulling force. CONSTRUCTION Conductor: Stranded circular or segmental (Milliken) compacted copper conductor Conductor shield: Semi-conductive shield Insulation: Cross-Linked Polyethylene(XLPE) Insulation shield: Semi-conductive shield Metal shielding layer:
Cavo in rame isolato XLPE da 110 kV da 630 mm² con guaina in alluminio ondulato saldato
Progettato per la trasmissione sotterranea da 110 kV, questo cavo in rame isolato XLPE da 630 mm² è dotato di una guaina in alluminio ondulato saldato per l'interramento diretto impermeabile al 100%. Conforme alla norma IEC 60840, ideale per sottostazioni, interramento di reti urbane e industria pesante. FAT di terze parti supportato.
Cavo conduttore in alluminio ACWU90 #8 AWG fino a 750 kcmil XLPE/alluminio armato/PVC
ACWU90 Aluminium Conductor Cable #8 AWG THRU 750 kcmil XLPE/aluminium Armoured /PVC Cable APPLICATION Suitable for urban underground power grids, power station outgoing lines, internal power supply lines of industrial and mining enterprises, etc. CONSTRUCTION Conductor: 8 AWG. thru 750 kcmil aluminum (8000 series aluminum) compact class “B” strand Insulation: Cross-linked Polyethylene (XLPE) Type RW90 Bonding Conductor (Ground): One (1) bare stranded aluminum (ACM) conductor
AWA Cavo di alimentazione ignifugo blindato a filo di alluminio CU/XLPE/CTS/AWA
AWA Aluminium Wire Armored Flame-retardant Power Cable CU/XLPE/CTS/AWA APPLICATION Industrial Power Networks: Suitable for factories, mining sites, and heavy machinery due to its armored design (AWA) and flame-retardant properties Commercial Buildings: Ensures safe power transmission in shopping malls, hospitals, and high-rises, where fire safety is critical Harsh Environments: Resists physical damage and moisture, making it ideal for outdoor installations or areas with
Cavo armato SWA 1.5mm2 3.6-35kV AL/XLPE/CWS/CTS/SWA/PVC per distribuzione di energia
1.5mm2 SWA Armoured Cable 3.6-35kV AL/XLPE/CWS/CTS/SWA/PVC for Power Distribution Application The core application of this 1.5mm² SWA Armoured Cable 3.6-35kV AL/XLPE/CWS/CTS/SWA/PVC is medium-voltage power underground direct burial, conduit installation, or fixed wiring. It is particularly suitable for occasions requiring mechanical protection and tensile strength, such as power distribution networks, industrial facilities, or infrastructure construction. Construction
OEM 1 Core PVC Cablo di alimentazione isolato di alluminio Conduttore 120mm 150mm
Single Core PVC Insulated Power Cable Aluminium Conductor 120mm 150mm Description This single-core electric cable is designed for efficient and reliable power transmission in various industrial, commercial, and residential applications. It features a high-quality aluminum (AL) or copper (CU) conductor, ensuring excellent electrical conductivity and durability. The cable is insulated and sheathed with polyvinyl chloride (PVC), providing superior protection against moisture,
Single Core HV High Voltage Power Cable 2XS(FL)2Y CU/XLPE/CWS/STA/PVC
Single Core HV High Voltage Power Cable 2XS(FL)2Y CU/XLPE/CWS/STA/PVC APPLICATION Urban underground networks (e.g., substation connections, industrial power distribution) Harsh environments requiring robust mechanical and chemical protection CONSTRUCTION Conductor: Stranded circular or segmental (Milliken) compacted copper conductor Conductor shield: Semi-conductive shield Insulation: Cross-Linked Polyethylene(XLPE) Insulation shield: Semi-conductive shield Metal
Cavo LSZH antincendio tripolare MV 8.7/15kV isolato in XLPE con armatura in nastro d'acciaio e guaina in PVC
Fire Protection LSZH Cable Three Core MV 8.7/15kV XLPE Insulated Steel Tape Armored PVC Sheathed Cable Product Overview Fire Rated Low Voltage Wire with 3 Core 1.5-400mm² is engineered to maintain circuit integrity during fire conditions, ensuring continuous power supply for critical emergency systems. Applications Suitable for power supply lines with flame retardant requirements, such as urban underground power grids, power station outgoing lines, and internal power lines of
Cable blindato in alluminio certificato CE AL/XLPE/STA/SWA/PVC 240mm2
CE Certified Aluminium Armoured Cable AL/XLPE/STA/SWA/PVC 240mm2 Cable Constuction ✔ XLPE Insulation (Cross-linked polyethylene) - Superior thermal stability (90°C rated) ✔ PVC Outer Sheath - UV resistant formulation (custom LSZH/Fire-resistant options availabl e)✔ Dual Certification - Compliant with IEC 60502-1 & GB/T 12706.1✔ Optional Armoring - Steel tape (YJLV22) or wire (YJLV32) for mechanical protection Advantages: ✔ Lower Power Loss – XLPE insulation ensures higher