pvc power cable
"
XHWW-2 Aluminiumleiter MC-Kabel 3 Kern 4 Kern 600 V Aluminiumdraht
XHWW-2 Aluminium Conductor Cable 3 Core 4 Core MC cable Application TypeXHHW-2MC cable is suitable for use as branch,feeder and service power distribution.It is suitable for use in wet or dry locations at temperature not to exceed 90°C.If it should be directly buried in the earth,MC cable with PVC sheathis an optimal choice.Maximum voltage rating for XHHW-2 application is 600Volts . Construction Type XHHW-2 conductors which is constructed with 8000 Series Aluminium Alloy
Mittelspannung 11 kV-Aufbündelungskabel ABC-Übertragungskabel
Medium Voltage 11kV Aerial Bundled ABC Cable Overhead Transmission Cable Application This product is suitable for overhead power lines that are easy to produce short circuit faults and safety hazards to humans and animals through dense forests and trees Construction Conductor : Aluminum (lightweight, cost-effective). Insulation :PE or PVC. Sheath : Typically low-smoke halogen-free (LSHF) compound for reduced toxicity and smoke emission during fires. Specifications No of cores
N2XBY NA2XBY 3 Kern Niederspannungskabel 0,6/1kV 0,5~800MM2 lV Kabel
N2XBY NA2XBY Low Voltage Cable 3 Core 0.6/1kV 0.5 ~ 800MM2 Construction Conductor: Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation: XLPE Filler: non-hygroscopic material Binder tape: non-hygroscopic material Sheath: PVC Characteristics Test Voltage: 3.5kV 5min No Breakdown The ambient temperature for installation: ≥0℃. Maximum conductor temperature in normal operation:≤90℃. Max operating temperature of con. When cable short-circuited(5s
BVR Kupferleiter Elektrokabel PVC Isolierte ausgestopfte Kupferdrähte OEM Logo
BVR Copper Conductor Electrical Wire PVC insulated Tinned Copper Wires Application Residential/Commercial Circuits : Used for lighting, socket outlets, and power distribution in homes, offices, and hotels. Control Systems : Wiring for switches, sensors, and low-voltage control panels. Features High Flexibility: Stranded copper for easy bending and tight-space installation (e.g., conduits, concealed wiring). Safety: Flame-retardant PVC insulation, compliant with GB/T 5023
Niederspannungs-LSZH-Kabel AL/ XLPE/AWA/SWA/PVC NA2XRH IEC 60502-1
Low Voltage LSZH Cable AL/ XLPE/AWA/SWA/PVC NA2XRH IEC 60502-1 APPLICATION LSZH cable with steel wire armour (SWA) is used in power networks, underground, outdoor, indoor applications and in cable ducting. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. CONSTRUCTION Conductor :Class 2 stranded aluminium conductor Insulation :XLPE (Cross-Linked Polyethylene) Filler : LSZH (Low Smoke Zero Halogen) Armour :Single core:
Aluminiumleiterkabel der Serie 8000 Allegierung Konzentrikkabel 2X8awg 3X8awg
8000 Series Aluminium Conductor Cable Al Alloy Concentric Cable 2X8awg 2X10awg Application The 8000 series aluminum alloy concentric cable is used in electric service entrance from the power distribution network to the meter pannel(especially where it is required to prevent electricity theft), and as feeder cable from the meter pannel to the distribution pannel.This cable an be used in dry and wet places, outdoors or directly buried.It has a maximum operating temperature of
0.6KV 1kv Niederspannung Aerial Bundled Kabel 1 2 3 4 Kerne ABC Draht XLPE isoliert
0.6/1kv Low Voltage Aerial Bundled Cable 1 2 3 4 Cores ABC Wire Applicatiom The aerial bundled cables designed for overhead distribution lines have all conductors made of aluminium, insulated with XLPE.Phase and neutral cores are laid up in a bundle with a left hand lay. Can be used for fixed installation as overhead power lines up to 1000V. Characteristics Voltage rating: 1kV Test voltage: 4kV, 5min no breakdown. Operating temperature PVC: -15°C to +70°C PE: -40°C to +70°C
Aluminiumlegierung Leiter Mittelspannungskabel 26kV 35kV XLPE / STA / PVC Isolierung
Aluminium Alloy Conductor Medium Voltage Cable 26/35kV XLPE/ STA/ PVC Application Used for tall building, Hospital, Theatre, Power station, Metro Tunnel or Petrochemical Industry or other special place required for low smoke , zero halogen clean and safe cable. Construction Conductor Conductor Shiel Insulation Metal Shield Layer Filler Binder Tape Armouring Outer sheath Laying Method Pipe laying, trench laying, tunnel laying, vertical shaft and bridge laying, etc. Specificati
Mehrfach-Paar verdrilltes, geschirmtes Instrumentenkabel 2/4/5/12 Paar 20awg 22awg 24awg
Multi Pair Twisted Shielded Instrument Cable 2/4/5/12 Pair 20awg 22awg 24awg APPLICATION Multi pair twisted cables are fundamental in modern communication and data transmission systems, offering reliable performance across various industries. Their structured design with individually twisted wire pairs minimizes electromagnetic interference (EMI) and crosstalk, making them indispensable in: Telecommunications Networking Infrastructure Industrial Automation Audio-Visual