logo
Trouvé 389 produits pour "

pvc power cable

"
Qualité XHWW-2 Conducteur en aluminium MC câble 3 noyau 4 noyau fil d'aluminium 600V Fabrique

XHWW-2 Conducteur en aluminium MC câble 3 noyau 4 noyau fil d'aluminium 600V

XHWW-2 Aluminium Conductor Cable 3 Core 4 Core MC cable Application TypeXHHW-2MC cable is suitable for use as branch,feeder and service power distribution.It is suitable for use in wet or dry locations at temperature not to exceed 90°C.If it should be directly buried in the earth,MC cable with PVC sheathis an optimal choice.Maximum voltage rating for XHHW-2 application is 600Volts . Construction Type XHHW-2 conductors which is constructed with 8000 Series Aluminium Alloy

Qualité Cable de transmission aérien à tension moyenne de 11 kV Fabrique

Cable de transmission aérien à tension moyenne de 11 kV

Medium Voltage 11kV Aerial Bundled ABC Cable Overhead Transmission Cable Application This product is suitable for overhead power lines that are easy to produce short circuit faults and safety hazards to humans and animals through dense forests and trees Construction Conductor : Aluminum (lightweight, cost-effective). Insulation :PE or PVC. Sheath : Typically low-smoke halogen-free (LSHF) compound for reduced toxicity and smoke emission during fires. Specifications No of cores

Qualité N2XBY NA2XBY câble à basse tension à trois cœurs 0.6/1kV 0.5~800MM2 lV Fabrique

N2XBY NA2XBY câble à basse tension à trois cœurs 0.6/1kV 0.5~800MM2 lV

N2XBY NA2XBY Low Voltage Cable 3 Core 0.6/1kV 0.5 ~ 800MM2 Construction Conductor: Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation: XLPE Filler: non-hygroscopic material Binder tape: non-hygroscopic material Sheath: PVC Characteristics Test Voltage: 3.5kV 5min No Breakdown The ambient temperature for installation: ≥0℃. Maximum conductor temperature in normal operation:≤90℃. Max operating temperature of con. When cable short-circuited(5s

Qualité BVR Conducteur de cuivre câble électrique PVC isolés fils de cuivre en conserve OEM Logo Fabrique

BVR Conducteur de cuivre câble électrique PVC isolés fils de cuivre en conserve OEM Logo

BVR Copper Conductor Electrical Wire PVC insulated Tinned Copper Wires Application Residential/Commercial Circuits ‌: Used for lighting, socket outlets, and power distribution in homes, offices, and hotels. ‌Control Systems ‌: Wiring for switches, sensors, and low-voltage control panels. Features High Flexibility: Stranded copper for easy bending and tight-space installation (e.g., conduits, concealed wiring). Safety: Flame-retardant PVC insulation, compliant with GB/T 5023

Qualité Le câble LSZH basse tension AL/ XLPE/AWA/SWA/PVC NA2XRH est conforme à la norme IEC 60502-1 Fabrique

Le câble LSZH basse tension AL/ XLPE/AWA/SWA/PVC NA2XRH est conforme à la norme IEC 60502-1

Low Voltage LSZH Cable AL/ XLPE/AWA/SWA/PVC NA2XRH IEC 60502-1 APPLICATION LSZH cable with steel wire armour (SWA) is used in power networks, underground, outdoor, indoor applications and in cable ducting. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. CONSTRUCTION Conductor :Class 2 stranded aluminium conductor Insulation :XLPE (Cross-Linked Polyethylene) Filler : LSZH (Low Smoke Zero Halogen) Armour :Single core:

Qualité Cable conducteur en aluminium de la série 8000 Al Alloy Cable concentrique 2X8awg 3X8awg Fabrique

Cable conducteur en aluminium de la série 8000 Al Alloy Cable concentrique 2X8awg 3X8awg

8000 Series Aluminium Conductor Cable Al Alloy Concentric Cable 2X8awg 2X10awg Application The 8000 series aluminum alloy concentric cable is used in electric service entrance from the power distribution network to the meter pannel(especially where it is required to prevent electricity theft), and as feeder cable from the meter pannel to the distribution pannel.This cable an be used in dry and wet places, outdoors or directly buried.It has a maximum operating temperature of

Qualité 0.6KV 1kv Basse tension câble aérien groupé 1 2 3 4 cœurs ABC fil XLPE isolé Fabrique

0.6KV 1kv Basse tension câble aérien groupé 1 2 3 4 cœurs ABC fil XLPE isolé

0.6/1kv Low Voltage Aerial Bundled Cable 1 2 3 4 Cores ABC Wire Applicatiom The aerial bundled cables designed for overhead distribution lines have all conductors made of aluminium, insulated with XLPE.Phase and neutral cores are laid up in a bundle with a left hand lay. Can be used for fixed installation as overhead power lines up to 1000V. Characteristics Voltage rating: 1kV Test voltage: 4kV, 5min no breakdown. Operating temperature PVC: -15°C to +70°C PE: -40°C to +70°C

Qualité Cable à tension moyenne en alliage d'aluminium 26kV 35kV XLPE / STA / PVC Fabrique

Cable à tension moyenne en alliage d'aluminium 26kV 35kV XLPE / STA / PVC

Aluminium Alloy Conductor Medium Voltage Cable 26/35kV XLPE/ STA/ PVC Application Used for tall building, Hospital, Theatre, Power station, Metro Tunnel or Petrochemical Industry or other special place required for low smoke , zero halogen clean and safe cable. Construction Conductor Conductor Shiel Insulation Metal Shield Layer Filler Binder Tape Armouring Outer sheath Laying Method Pipe laying, trench laying, tunnel laying, vertical shaft and bridge laying, etc. Specificati

Qualité Câble d'instrumentation blindé à paires torsadées multiples 2/4/5/12 paires 20awg 22awg 24awg Fabrique

Câble d'instrumentation blindé à paires torsadées multiples 2/4/5/12 paires 20awg 22awg 24awg

Multi Pair Twisted Shielded Instrument Cable 2/4/5/12 Pair 20awg 22awg 24awg APPLICATION Multi pair twisted cables are fundamental in modern communication and data transmission systems, offering reliable performance across various industries. Their structured design with individually twisted wire pairs minimizes electromagnetic interference (EMI) and crosstalk, making them indispensable in: Telecommunications Networking Infrastructure Industrial Automation Audio-Visual