Aluminium Twisted ABC Aerial Bundle Cable Service Drop Wire PVC Geïsoleerd voor overhead
| Nominal Cross Section: | 10-500 m² mm | Conductor: | Aluminiumleider |
| Phase Conductor: | AL/ALOY | Size: | 10-150 mm2 |
| Oem: | Geaccepteerd | Range Of Application: | Overhead |
| High Light: | Aluminium-gewrongen ABC-aerial bundle kabel,PVC-geïsoleerde service-dropdraad |
||
Aluminium Twisted ABC Aerial Bundle Cable Service Drop Wire PVC Geïsoleerde Overhead Application Cable
Aanvraag
Voornamelijk gebruikt voor luchtverlichting, buitenverlichting en tijdelijke dienstverlening voor de bouw, To be used at voltage of 600V to 2200V phase-to-phase or less at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross liked polyethylene insulated conductors.
Bouw
- Fasegeleider: aluminiumdraad, 1350-H19
- Neutrale geleider: Aluminiumdraad 1350-H19, Alle legering Aluminiumgeleider 6201, Aluminiumgeleider Versterkt staal
- Isolatie: XLPE,PE,PVC
Specificatie
|
Aantal kernen x nominale doorsnede |
Algemene diameter |
Gewicht |
Maximale weerstand van de geleider |
Minimale breekbelasting |
Huidige rating |
|
Nr.x mm^2 |
mm |
Kg/Km |
Ω/Km |
KN: |
Een |
|
2x10 RM |
12.8 |
93 |
3.08 |
1.5 |
38 |
|
4x10 RM |
15.4 |
183 |
3.08 |
1.5 |
38 |
|
2x16 RM |
14.8 |
129 |
1.91 |
2.3 |
72 |
|
2x16 RN + 2x1.5 RE |
14.8 |
176 |
1.910/12.100 |
2.3 |
72 |
|
4x16 RM |
17.8 |
257 |
1.91 |
2.3 |
72 |
|
4x16 RN + 2x1,5 RE |
17.8 |
304 |
1.910/12.100 |
2.3 |
72 |
|
2x25 RM |
18 |
202 |
1.2 |
3.8 |
107 |
|
2x25 RM + 2x1,5 RE |
18 |
249 |
1.200/12.100 |
3.8 |
107 |
|
4x25 RM |
21.7 |
404 |
1.2 |
3.8 |
107 |
|
4x25 RM + 2x1,5 RE |
21.7 |
451 |
1.200/12.100 |
3.8 |
107 |
|
2x35 RM |
20.8 |
269 |
0.868 |
5.2 |
132 |
|
2x35 RM + 2x1,5 RE |
20.8 |
316 |
0.868/12.100 |
5.2 |
132 |
|
4x35 RM |
25.1 |
539 |
0.868 |
5.2 |
132 |
|
4x35 RM + 2x1,5 RE |
25.1 |
586 |
0.868/12.100 |
5.2 |
132 |
|
2x50 RM |
23.4 |
352 |
0.641 |
7.6 |
165 |
|
2x50 RM + 2x1,5 RE |
23.4 |
399 |
0.641/12.100 |
7.6 |
165 |
|
1x54,6 RM + 3x25 RM |
21.7 |
507 |
0.630/1.200 |
3.8 |
107 |
|
1x54,6 RM + 3x25 RM + 1x16 RM |
24.3 |
573 |
0.630/1.200/1.910 |
3.8/2.3 |
107/72 |
|
1x54,6 RM + 3x25 RM + 2x16 RM |
29.7 |
639 |
0.630/1.200/1.910 |
3.8/2.3 |
107/72 |
|
1x54,6 RM + 3x25 RM + 3x16 RM |
31.1 |
705 |
0.630/1.200/1.910 |
3.8/2.3 |
107/72 |
|
1x54,6 RM + 3x35 RM |
25.1 |
615 |
0.630/0.868 |
5.2 |
132 |
|
1x54,6 RM + 3x35 RM + 1x16 RM |
28.1 |
680 |
0.630/0.868/1.910 |
5.2/2.3 |
132/72 |
|
1x54,6 RM + 3x35 RM + 2x16 RM |
34.3 |
748 |
0.630/0.868/1.910 |
5.2/2.3 |
132/72 |
|
1x54,6 RM + 3x35 RM + 3x16 RM |
35.9 |
814 |
0.630/0.868/1.910 |
5.2/2.3 |
132/72 |
|
1x54,6 RM + 3x35 RM + 1x25 RM |
28.1 |
714 |
0.630/0.868/1.200 |
5.2/3.8 |
132/107 |
|
1x54,6 RM + 3x50 RM |
28.2 |
741 |
0.630/0.641 |
7.6 |
165 |
|
1x54,6 RM + 3x50 RM + 1x16 RM |
31.6 |
806 |
0.630/0.641/1.910 |
7.6/2.3 |
165/72 |
|
1x54,6 RM + 3x50 RM + 2x16 RM |
38.6 |
875 |
0.630/0.641/1.910 |
7.6/2.3 |
165/72 |
|
1x54,6 RM + 3x50 RM + 3x16 RM |
40.4 |
940 |
0.630/0.641/1.910 |
7.6/2.3 |
165/72 |
|
1x54,6 RM + 3x50 RM + 1x25 RM |
31.6 |
841 |
0.630/0.641/1.200 |
7.6/3.8 |
165/107 |
|
1x54,6 RM + 3x70 RM |
33 |
950 |
0.630/0.443 |
10.2 |
205 |
|
1x54,6 RM + 3x70 RM + 1x16 RM |
37 |
1014 |
0.630/0.443/1.910 |
10.2/2.3 |
205/72 |
|
1x54,6 RM + 3x70 RM + 2x16 RM |
45.2 |
1083 |
0.630/0.443/1.910 |
10.2/2.3 |
205/72 |
|
1x54,6 RM + 3x70 RM + 3x16 RM |
47.3 |
1148 |
0.630/0.443/1.910 |
10.2/2.3 |
205/72 |
|
1x54,6 RM + 3x70 RM + 1x25 RM |
37 |
1048 |
0.630/0.443/1.200 |
10.2/3.8 |
205/107 |
|
1x54,6 RM + 3x70 RM + 2x25 RM |
45.2 |
1150 |
0.630/0.443/1.200 |
10.2/3.8 |
205/107 |
|
1x54,6 RM + 3x70 RM + 3x25 RM |
47.3 |
1250 |
0.630/0.443/1.200 |
10.2/3.8 |
205/107 |
|
1x54,6 RM + 3x95 RM |
37.4 |
1176 |
0.630/0.320 |
13.5 |
240 |
|
1x54,6 RM + 3x95 RM + 1x16 RM |
41.9 |
1243 |
0.630/0.320/1.910 |
13.5/2.3 |
240/72 |
-
Ca new design cable for our projects, good quality
-
Tperfect