Halogeenkabel met weinig rook
0.6/1kV LSZH stroomkabel CU/XLPE/AWA/LSZH.
0.6/1kV LSZH Power Cable CU/XLPE/AWA/LSZH | IEC 61034-2 Certified Low Smoke Emission Product Overview Reliable Low Smoke Zero Halogen Armoured Power Cable for Indoor & Underground Installation The 0.6/1kV CU/XLPE/AWA/LSZH Power Cable is a high-performance low voltage power cable designed for safe power transmission in buildings, industrial plants, public infrastructure, and underground distribution systems. Manufactured with copper conductor, XLPE insulation, aluminum wire
Cu/XLPE/CTS/LSZH/FR/PE 19/33kV 3×300mm² Middenspanningskabel
Cu/XLPE/CTS/LSZH/FR/PE 19/33kV 3×300mm² Medium Voltage Power Cable Product Overview The Cu/XLPE/CTS/LSZH/FR/PE 19/33kV 3×300mm² is a high-performance medium voltage power cable designed for critical power distribution networks. This three-core copper cable is manufactured to the highest international standards, featuring cross-linked polyethylene (XLPE) insulation and a copper tape screen (CTS) for superior electrical performance. Rated at 19/33kV, this cable is specifically
LSZH-laagspanningskabel AL/ XLPE/AWA/SWA/PVC NA2XRH IEC 60502-1
Low Voltage LSZH Cable AL/ XLPE/AWA/SWA/PVC NA2XRH IEC 60502-1 APPLICATION LSZH cable with steel wire armour (SWA) is used in power networks, underground, outdoor, indoor applications and in cable ducting. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. CONSTRUCTION Conductor :Class 2 stranded aluminium conductor Insulation :XLPE (Cross-Linked Polyethylene) Filler : LSZH (Low Smoke Zero Halogen) Armour :Single core:
LSZH brandwerend meerkernig elektrisch kabeldraad XLPE afgeschermd PVC geïsoleerd stroomkabel
LSZH Fireproof Multi-Core Electric Cable Wire XLPE Shielded PVC Insulated Power Cable APPLICATION The cable is commonly used in environments that require high safety standards, especially in situations where fire hazards need to be minimized, and the cable must ensure reliable power transmission. CONSTRUCTION C onductor: The first or second type of copper conductor In s u lation:XLPE Sheath: LSZH STANDARD VDE 0276 part 604, VDE 0482-266-2, DIN EN 60332-3 / EN50266-2 ADVANTAGE
Vlamvertrager, rookvrije halogeenkabel, ideaal voor industriële elektrische bedrading en toepassingen voor de naleving van veiligheidsvoorschriften
Product Description: The LSZH Power Cable, also known as Low Smoke Zero Halogen Cable, represents a significant advancement in cable technology designed to enhance safety and environmental performance in various electrical installations. This type of cable is engineered to emit very low levels of smoke and no halogen gases when exposed to fire or extreme heat, making it an ideal choice for applications where fire safety and air quality are of paramount importance. The Low
Vlamvertrager, rookarme halogeenkabel, geschikt voor industriële elektrische bedrading en toepassingen voor de naleving van veiligheidsvoorschriften
Product Description: The Low Smoke Zero Halogen Cable is an advanced wiring solution designed to enhance safety and performance in various electrical and electronic applications. This cable is engineered with materials that produce minimal smoke and no halogen gases when exposed to fire or high temperatures, making it an ideal choice for environments where fire safety is a critical concern. The Zero Halogen Low Smoke Wire offers superior resistance to fire hazards, significan
LSZH besturingskabel koperen geleider XLPE geïsoleerde koperdraad afgeschermd CU/XLPE/CWS/PVC NYCY N2YCY
LSZH Control Cable Copper Conductor XLPE Insulated Copper Wire Screened CU/XLPE/CWS/PVC NYCY N2YCY APPLICATION LSZH Control Cable with Copper Conductor, XLPE Insulated, and Copper Wire Screened is primarily used in electrical control systems where safety and fire resistance are critical. It is suitable for wiring in power distribution units, industrial control panels, and monitoring circuits (rated voltage up to 450/750V AC) CONSTRUCTION Conductor Circular solid
Brandwerende LSZH-kabel met drie aders MV 8.7/15kV XLPE-geïsoleerde staalbandgepantserde PVC-mantelkabel
Fire Protection LSZH Cable Three Core MV 8.7/15kV XLPE Insulated Steel Tape Armored PVC Sheathed Cable Product Overview Fire Rated Low Voltage Wire with 3 Core 1.5-400mm² is engineered to maintain circuit integrity during fire conditions, ensuring continuous power supply for critical emergency systems. Applications Suitable for power supply lines with flame retardant requirements, such as urban underground power grids, power station outgoing lines, and internal power lines of
LSZH Silicium Brandmeldkabel Brandbestendige kabel 50-1200mm2 IEC60331
LSZH Silicon Fire Alarm Cable Fire Resistant Cable 50-1200mm2 IEC60331 APPLICATION Low-smoke, halogen-free medium-voltage cables (LSZH MV cables) are widely used in critical infrastructure and safety-sensitive environments due to their fire-resistant and environmentally friendly properties. Key application scenarios include: Urban Public Buildings Underground Transportation Systems Industrial Facilities Renewable Energy Projects CONSTRUCTION Conductor: Circular stranded,
Middenspanningslaagrookhalogeenkabel LSZH 19/33 (36) kV CU/XLPE/SWA/LSZH EN60228
Medium Voltage Low Smoke Zero Halogen Cable LSZH 19/33 (36)kV CU/XLPE/SWA/ LSZH EN60228 APPLICATION For installation in ground, outdoors, indoors and in cable ducts forpower station, industry and distribution networks. CONSTRUCTION Conductor: Circular stranded, compacted copper conductor or aluminum conductor, class 2 Conductor Screen: Semi-conducting Compound Insulation: XLPE (Cross-linked polyethylene) Insulation Screen: Semi-conducting Compound Metallic Screen: Copper Tape
Kabel met lage rookontwikkeling en zonder halogenen LSZH IEC 60502 N2XH 4-aderig 5-aderig Meeraderig EN 60332-3
Low Smoke Zero Halogen Cable LSZH IEC 60502 N2XH 4 Core 5 Core Multi Core EN 60332-3 APPLICATION Low-smoke zero-halogen (LSZH) cables are widely used in environments where fire safety and air quality are critical CONSTRUCTION C onductor: The first or second type of copper conductor In s u lation:XLPE Sheath: LSZH STANDARD VDE 0276 part 604, VDE 0482-266-2, DIN EN 60332-3 / EN50266-2 ADVANTAGE Halogen-free: Prevents acidic gas formation Low smoke: Maintains visibility in
IEC 60502 N2XH Low Smoke Zero Halogen LSZH Kabel XLPE Geïsoleerd 0.6KV 1kV
IEC 60502 N2XH Low Smoke Zero Halogen Cable XLPE Insulated 0.6/1kV Application Low smoke zero halogen cables are becoming more popular in military applications, aircraft, railway and maritime. This is because in these areas it is often difficult to ventilate in the event of a fire.. Besides, Low smoke halogen free material is also widely used in high pressure underground tunnels or track marking lines in railway system. when using them, reduces the possibility of harmful
Single Core Low Voltage Low Smoke Zero Halogen Cable LSZH TUV gecertificeerd
Single Core Low Voltage Low Smoke Zero Halogen Cable LSZH TUV Certificated Application The Cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit
Hoogtemperatuurbestendige, rookvrije, halogeenvrije LSZH-kabel kopergeleider
High Temperature Resistant Low Smoke Zero Halogen Cable Copper Conductor Screen Application The Cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial,aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short
6/10 KV Medium Voltage Low Smoke Zero Halogen LSZH Draad Brandwerend
6/10 KV Medium Voltage Low Smoke Zero Halogen Cable LSZH Fire Resistant Application Medium-voltage low-smoke zero-halogen (LSZH) cables are engineered for applications prioritizing fire safety, minimal toxic emissions, and environmental protection. Construction Conductor :Class 2 stranded copper conductor Insulation :XLPE (Cross-Linked Polyethylene) Bedding :LSZH (Low Smoke Zero Halogen) Armour :STA (Steel Tape Armour) Sheath :LSZH (Low Smoke Zero Halogen) Advantage Enhanced
Middenspanningslaagrook Halogeenstroomkabel 18/30 36kV 19/33 36 KV 3 Core
Medium Voltage Low Smoke Zero Halogen Cable 18/30 36kV 19/33 36 KV 3 Core Application Industrial Automation & Process Control : Hazardous Environments Public Infrastructure Building Management Systems Transportation Networks Renewable Energy Characteristics LSZH sheathing resists flame spread and reduces smoke density. Copper/aluminum shielding ensures signal accuracy in noisy environments. Halogen-free construction aligns with IEC 60092 , IEEE 802.3
Vlamvertrager met weinig rook en geen halogeenkabel 0,6kV 1kV XLPE geïsoleerd YJY23
Flame Retardant Low Smoke Zero Halogen Cable 0.6/1kV XLPE Insulated YJY23 Application Industrial Factory Power Distribution Systems High-Risk Buildings Transportation Infrastructure Hazardous Environments Emergency Systems Construction Conductor :Class 2 stranded copper conductor Insulation :XLPE (Cross-Linked Polyethylene) Bedding :LSZH (Low Smoke Zero Halogen) Armour :SWA (Steel Wire Armour) Sheath :LSZH (Low Smoke Zero Halogen) Advantage Composite high
Stalen band STA Halogeenvrije kabel van lage rookkwaliteit Klasse 2 Leider N2X2Y Vlamvertrager
Steel Tape STA Low Smoke Zero Halogen Cable Class 2 conductor N2X2Y Application Flame-retardant low-smoke zero-halogen (LSZH/LSOH) cables are widely applied in various critical scenarios due to their enhanced safety and environmental features: Transportation Systems:Deployed in metro systems, light rail transit, and aviation facilities to ensure safe power transmission while minimizing toxic emissions during fire incidents Public Infrastructure: Used in hospitals, schools,
Drie-kern LSZH Halogeenkabel met lage rook en nul met koperen geleider 600V spanning
Three core Low Smoke Zero Halogen Cable Copper Conductor For 600V Voltage Application Low smoke zero halogen cables are becoming more popular in military applications, aircraft, railway and maritime. This is because in these areas it is often difficult to ventilate in the event of a fire.. Besides, Low smoke halogen free material is also widely used in high pressure underground tunnels or track marking lines in railway system. when using them, reduces the possibility of
XLPE geïsoleerde halogeenvrije kabel met een lage rookwaarde met een enkele kern van 1900 3300 V
XLPE Insulated Low Smoke Zero Halogen Cable Amoured 1900 3300V Application Low smoke zero halogen cables are becoming more popular in military applications, aircraft, railway and maritime. This is because in these areas it is often difficult to ventilate in the event of a fire.. Besides, Low smoke halogen free material is also widely used in high pressure underground tunnels or track marking lines in railway system. when using them, reduces the possibility of harmful gases
LSZH Flexible Screened Low Smoke Zero Halogen Cable voor buiten en ondergronds
LSZH Flexible Screened Low Smoke Zero Halogen Cable For Outdoor and Underground Application Low smoke halogen-free flexible screened cable for instrumentation and control equipment in tooling machinery, production lines, and flexible applications with free movement without tensile load. Suitable for use in dry, ambient and wet rooms. The screen protects against external interference pulses for interference-free transmission. These cables are not used for outdoor or undergroun
Gepantserde koperblazers met weinig rook en geen halogeenstroomkabel SWA 0.6/1 KV 3x4mm
Armored Copper Low Smoke Zero Halogen SWA 0.6/1 KV 3*4mm Application Low Smoke Zero Halogen (LSZH) cables are a reliable and high-performance solution for applications demanding superior safety, environmental protection, and compliance with stringent standards. Their low smoke emission, zero halogen properties, and flame-retardant characteristics make them ideal for public buildings, transportation infrastructure, industrial facilities, high-rise buildings, and data centers,
Multi Core LSZH Low Smoke Zero Halogen Cable XLPE Steel Wire Gepantserd
Multi Core Low Smoke Zero Halogen Cable XLPE Steel Wire Armoured Application For fixed installation of the transmission and distribution systems, tunnels and pipelines and other occasions .For situation not suppose to bear the external mechanical force. Constructions Conductor: Plain circular stranded copper conductor, conform to IEC 60228 class 2 Insulation: XLPE Amour: Steel Wire armour Core Conductor :annealed copper (stranded core) Popular sizes: 2~5 core x1.5~630mm²
Olieweerstand LSZH Beschermde stroomkabel Gepantserde Cu XLPE Swb PVC elektrische draad
Oil Resistance LSZH Shielded Instrument Cable Armoured Cu/XLPE/Swb/PVC Application It is suitable for a wide range of applications, including industrial, commercial and residential power distribution systems. Parameter Voltage Rating :300V Operating Temperature :Fixed: -40°C to +80°C Flexed: 0°C to +50°C Minimum internal bending radius 6*cable Diameter Conductor :0.5mm² - 0.75mm²: Copper 1mm² and above: Copper Construction Insulation :XLPE Collective Screen :Al/PET (Aluminium