industrial control cable
"
Aluminum Conductor PVC Electric Cable AL/PVC/PVC for Electrical Installation NAYY
Aluminum Conductor PVC Electric Cable AL/PVC/PVC for Electrical Installation NAYY APPLICATION Aluminum Conductor PVC Insulated and Sheathed Electric Cable (AL/PVC/PVC) is primarily used for low-voltage electrical installations in buildings, industrial facilities, and infrastructure projects. Its applications include: Building Wiring: Suitable for internal wiring in residential, commercial, and public buildings due to its flexibility and ease of installation. Industrial
Philippine Standards Medium Voltage XLPE Insulated Power Cable for Industrial Use USE-2 Cable
Philippine Standards Medium Voltage XLPE Insulated Power Cable for Industrial Use USE-2 Cable APPLICATION Suitable for power supply lines with flame retardant requirements, such as urban underground power grids, power station outgoing lines, and internal power lines of industrial and mining enterprises. CONSUCTRUCTION Conductor:Class 2 stranded plain copper conductor Conductor screen:Semi-conducting material Insulation:XLPE Insulation Screen:Semi-conducting material Metallic
NA2XY – YJLV (AL/XLPE/PVC) Single Core 0.6/1kV – Aluminum Power Cable for Low Voltage Distribution
A2XY YJLV (AL/XLPE/PVC) Single Core 0.6/1kV Aluminum Power Cable for Low Voltage Distribution Product Overview The NA2XY YJLV (AL/XLPE/PVC) Single Core 0.6/1kV is a high-performance low voltage power cable designed for reliable and cost-effective electricity distribution in 0.6/1kV systems. This cable features an aluminum conductor, XLPE (cross-linked polyethylene) insulation, and a PVC outer sheath. Offering an excellent balance between cost efficiency and electrical
0.6/1kV Fire Resistant Power Cable EN 60332-3-24 for Critical Infrastructure
0.6/1kV Fire Resistant Power Cable EN 60332-3-24 for Critical Infrastructure Product Overview Designed for life safety and critical power continuity , this 0.6/1kV Fire Resistant Power Cable ensures circuit integrity during a fire event. Rated for 0.6/1kV (U/U), this cable combines XLPE insulation for high thermal performance with steel wire armor (SWA) for mechanical protection. Crucially, it complies with EN 60332-3-24 Category C for vertical flame spread on bunched cables
STA Shielded Instrument Cable Flame Retardant Computer Cable
STA Shielded Instrument Cable Flame Retardant Computer Cable APPLICATION Industrial automation systems (PLC, DCS, SCADA) Power plants, chemical plants, and mining facilities Data centers and computer rooms requiring EMI shielding Underground or hazardous locations requiring flame retardancy CONSTRUCTION C onductor: The first or second type of copper conductor In s u lation: Low density polyethylene (LLDPE) Fill er (optional): Filling rope Separate shielding: Braided shielding
Fire Resistant XLPE Insulated Power Cable 1.5-800mm2 1-5 Core CU/XLPE/PVC
Fire Resistant XLPE Insulated Power Cable 1.5-800mm2 1-5 Core CU/XLPE/PVC APPLICATION The cable is a fire-resistant , XLPE-insulated , and PVC-sheathed power cable rated for voltages up to 0.6/1 kV . It is widely used in: Power Distribution Systems Suitable for fixed installations in buildings, industrial plants, and infrastructure projects, delivering reliable power transmission in low-voltage networks. Fire Safety Critical Areas The "N" (fire-resistant)
64/110kV HV High Voltage Power Cable 1X630mm IEC 60840 IEC 62067
64/110kV HV High Voltage Power Cable 1X630mm IEC 60840 IEC 62067 APPLICATION Urban Power Distribution: Transmits electricity efficiently in densely populated areas. Industrial Power Supply: Supports large-scale industrial facilities with high energy demands. Renewable Energy Integration: Connects wind/solar farms to the grid. CONSTRUCTION Conductor: Stranded circular or segmental (Milliken) compacted copper conductor Conductor shield: Semi-conductive shield
Power Distribution Industrial MV Power Cable 26/35kV AL/XLPE/CTS/STA/PVC YJLV22 NA2XSEBY
Power Distribution Industrial MV Power Cable 26/35kV AL/XLPE/CTS/STA/PVC YJLV22 NA2XSEBY Application 1. Underground and outdoor power networks2. Cable duct installations3. Industrial substations4. Commercial power distribution5. Renewable energy systems6. Mining and heavy industry7. Telecommunications infrastructure8. Smart grid deployments Construction Conductor: Class 2 Aluminium conductor Conductor: Semi-conductive shield Insulation: Cross-Linked Polyethylene(XLPE)
24 Pairs Double Shielded Twisted Pair Computer Cable Armoured Overall Screen 12 Pair Instrument Cable
24 Pairs Double Shielded Twisted Pair Computer Cable Armoured Overall Screen 12 Pair Instrument Cable APPLICATION The cables are used in electric equipment, household, and electrical appliance. CONSTRUCTION Conductor: AS/NZS 1125:2001, Stranded,annealed plain copper wire Insulation: V-90 insulation Armouring: Aluminium Foil Jacket: PVC CHARA C TERISTIC Operating Temperature: max 90deg C Min Bending radius: 6 times cable diameter Phase Core: red, white or blue Neutral Core: