aluminum conductor cable
"
عاري كل سبيكة الألومنيوم الموصل المتدفق AAAC AAC ACSR الموصل الهوائي
Overhead Bare Conductor All Aluminium Alloy Stranded AAAC,AAC,ACSR Cable AAC - All Aluminum Conductor Application This all aluminum conductor is a kind of aluminum product made through stranding aluminum wires. It is used for the electricity distribution lines with short span length and small load-carrying capability of the pole. The AAC provides reliable performance for overhead power transmission and distribution lines. This standard covers hard drawn circular aluminum
كابل طاقة بجهد عالٍ 38/66 كيلو فولت (72.5 كيلو فولت) موصل نحاسي عازل XLPE غلاف رصاص
38/66kV(72.5kV) High Voltage Cable Copper Conductor XLPE Insulation Lead Sheath Power Cable APPLICATION The cable is suitable for use in high voltage transmission networks, in systems of rated voltages from 60 kV grade up to and including 69 kV grade. CONSTRUCTION Conductor: Stranded circular or segmental (Milliken) compacted copper conductor Conductor shield: Semi-conductive shield Insulation: Cross-Linked Polyethylene(XLPE) Insulation shield: Semi-conductive shield Metal
64/110kv HV High Voltage Power Cable CU/XLPE/CWS/STA 123kV 300-2500mm Power Cable
64/110kv HV High Voltage Power Cable CU/XLPE/CWS/STA 123kV 300-2500mm Power Cable APPLICATION The cable is suitable for use in high voltage transmission networks, in systems of rated voltages from 110 kV grade up to and including 115 kV grade. CONSTRUCTION Conductor: Stranded circular or segmental (Milliken) compacted copper conductor Conductor shield: Semi-conductive shield Insulation: Cross-Linked Polyethylene(XLPE) Insulation shield: Semi-conductive shield Metal shielding
15kV 35kV ACSR موصل ABC كابل متكامل جوي كابل فوقي متوسط الجهد
15kV 35kV ACSR Conductor ABC Aerial Bundled Cable Medium Voltage Overhead Cable APPLICATION 1 phase:t o supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 1000 volts or lower at a conductor temperature of 75℃ maximum. 2 phase: t o supply power from the utility ’ s lines to the consumer ’ s weatherhead. For service at 1000 volts or less (phase to phase) at a conductor temperature of 75℃ maximum for polyethylen
3 النواة XLPE عازل الموصلات الألومنيوم STA سلك الطاقة المدرع NA2XBY
3 Core XLPE Insulated Aluminium Conductor STA Armoured Power Cable NA2XBY APPLICATION Primarily used in power supply stations, industrial facilities, and switchboards Suitable for indoor installation in cable ducts and outdoor environments Can be installed underground and in water applications Commonly employed in power distribution systems for industries Used in cable tray installations for various industrial applications CONSTRUCTION Conductor: Class 2 stranded aluminum
LSZH كابل إنذار الحريق السيليكوني كابل مقاوم للحريق 50-1200mm2 IEC60331
LSZH Silicon Fire Alarm Cable Fire Resistant Cable 50-1200mm2 IEC60331 APPLICATION Low-smoke, halogen-free medium-voltage cables (LSZH MV cables) are widely used in critical infrastructure and safety-sensitive environments due to their fire-resistant and environmentally friendly properties. Key application scenarios include: Urban Public Buildings Underground Transportation Systems Industrial Facilities Renewable Energy Projects CONSTRUCTION Conductor: Circular stranded,
كابل طاقة ABC ذاتي الدعم جوي مجمع IEC228 IEC208 IEC502 لخط توزيع علوي
ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228 IEC208 IEC502 For Overhead Distribution Line APPLICATION 1 phase:t o supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 1000 volts or lower at a conductor temperature of 75℃ maximum. 2 phase: t o supply power from the utility ’ s lines to the consumer ’ s weatherhead. For service at 1000 volts or less (phase to phase) at a conductor temperature of 75
الألومنيوم الملتوية ABC الهوائية حزمة كابل الخدمة أسلاك قطرة PVC معزولة للأسعار العالية
Aluminium Twisted ABC Aerial Bundle Cable Service Drop Wire PVC Insulated Overhead Application Cable Applicatiom Primarily used for overhead service application such as street lighting,outdoor lighting,and temporary service for construction, To be used at voltage of 600V to 2200V phase-to-phase or less at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross liked polyethylene insulated conductors. Construction Phase conductor:
الشاشة السلكية النحاسية MV كابل الطاقة XLPE معزول ثلاثة النواة 21/35kV
Copper Wire Screen Medium Voltage Cable XLPE Insulted Three Core 21/35kV Application Medium voltage power cable for static application in ground, within and outside facilities, outdoor, in cable canals,in water, in conditions where cables are not exposed to heavier mechanical stress and tensile strain. Construction C onductor : Stranded copper or aluminum conductor shield :: Extruded semi-conductive compound I nsulation : Cross-linked polyethylene (xlpe) I nsulation shield :