품질 맨 알루미늄 합금 선도자 스트랜드 AAAC AAC ACSR 공기선 선도자 공장

맨 알루미늄 합금 선도자 스트랜드 AAAC AAC ACSR 공기선 선도자

Overhead Bare Conductor All Aluminium Alloy Stranded AAAC,AAC,ACSR Cable AAC - All Aluminum Conductor Application This all aluminum conductor is a kind of aluminum product made through stranding aluminum wires. It is used for the electricity distribution lines with short span length and small load-carrying capability of the pole. The AAC provides reliable performance for overhead power transmission and distribution lines. This standard covers hard drawn circular aluminum

품질 38/66kV(72.5kV) 고압 케이블 구리 도체 XLPE 절연체 납 피복 전력 케이블 공장

38/66kV(72.5kV) 고압 케이블 구리 도체 XLPE 절연체 납 피복 전력 케이블

38/66kV(72.5kV) High Voltage Cable Copper Conductor XLPE Insulation Lead Sheath Power Cable APPLICATION The cable is suitable for use in high voltage transmission networks, in systems of rated voltages from 60 kV grade up to and including 69 kV grade. CONSTRUCTION Conductor: Stranded circular or segmental (Milliken) compacted copper conductor Conductor shield: Semi-conductive shield Insulation: Cross-Linked Polyethylene(XLPE) Insulation shield: Semi-conductive shield Metal

품질 64/110kv HV High Voltage Power Cable CU/XLPE/CWS/STA 123kV 300-2500mm Power Cable 공장

64/110kv HV High Voltage Power Cable CU/XLPE/CWS/STA 123kV 300-2500mm Power Cable

64/110kv HV High Voltage Power Cable CU/XLPE/CWS/STA 123kV 300-2500mm Power Cable APPLICATION The cable is suitable for use in high voltage transmission networks, in systems of rated voltages from 110 kV grade up to and including 115 kV grade. CONSTRUCTION Conductor: Stranded circular or segmental (Milliken) compacted copper conductor Conductor shield: Semi-conductive shield Insulation: Cross-Linked Polyethylene(XLPE) Insulation shield: Semi-conductive shield Metal shielding

품질 15kV 35kV ACSR 선도자 ABC 에어리얼 펀들드 케이블 중압 오버헤드 케이블 공장

15kV 35kV ACSR 선도자 ABC 에어리얼 펀들드 케이블 중압 오버헤드 케이블

15kV 35kV ACSR Conductor ABC Aerial Bundled Cable Medium Voltage Overhead Cable APPLICATION 1 phase:t o supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 1000 volts or lower at a conductor temperature of 75℃ maximum. 2 phase: t o supply power from the utility ’ s lines to the consumer ’ s weatherhead. For service at 1000 volts or less (phase to phase) at a conductor temperature of 75℃ maximum for polyethylen

품질 3심 XLPE 절연 알루미늄 도체 STA 아머드 전력 케이블 NA2XBY 공장

3심 XLPE 절연 알루미늄 도체 STA 아머드 전력 케이블 NA2XBY

3 Core XLPE Insulated Aluminium Conductor STA Armoured Power Cable NA2XBY APPLICATION Primarily used in power supply stations, industrial facilities, and switchboards Suitable for indoor installation in cable ducts and outdoor environments Can be installed underground and in water applications Commonly employed in power distribution systems for industries Used in cable tray installations for various industrial applications CONSTRUCTION ‌Conductor: Class 2 stranded aluminum

품질 LSZH 실리콘 화재 경보 케이블 내화 케이블 50-1200mm2 IEC60331 공장

LSZH 실리콘 화재 경보 케이블 내화 케이블 50-1200mm2 IEC60331

LSZH Silicon Fire Alarm Cable Fire Resistant Cable 50-1200mm2 IEC60331 APPLICATION Low-smoke, halogen-free medium-voltage cables (LSZH MV cables) are widely used in critical infrastructure and safety-sensitive environments due to their fire-resistant and environmentally friendly properties. Key application scenarios include: ‌Urban Public Buildings ‌Underground Transportation Systems ‌Industrial Facilities ‌ Renewable Energy Projects CONSTRUCTION Conductor: Circular stranded,

품질 ACSRC 자립형 공중 번들 ABC 전력 케이블 IEC228 IEC208 IEC502 가공 배전선용 공장

ACSRC 자립형 공중 번들 ABC 전력 케이블 IEC228 IEC208 IEC502 가공 배전선용

ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228 IEC208 IEC502 For Overhead Distribution Line APPLICATION 1 phase:t o supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 1000 volts or lower at a conductor temperature of 75℃ maximum. 2 phase: t o supply power from the utility ’ s lines to the consumer ’ s weatherhead. For service at 1000 volts or less (phase to phase) at a conductor temperature of 75

품질 알루미늄 트위스트 ABC 에어리얼 펀들 케이블 서비스 드롭 와이어 PVC 오버헤드용 단열 공장

알루미늄 트위스트 ABC 에어리얼 펀들 케이블 서비스 드롭 와이어 PVC 오버헤드용 단열

Aluminium Twisted ABC Aerial Bundle Cable Service Drop Wire PVC Insulated Overhead Application Cable Applicatiom Primarily used for overhead service application such as street lighting,outdoor lighting,and temporary service for construction, To be used at voltage of 600V to 2200V phase-to-phase or less at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross liked polyethylene insulated conductors. Construction Phase conductor:

품질 구리 와이어 스크린 MV 전원 케이블 XLPE 단열 3 코어 21/35kV 공장

구리 와이어 스크린 MV 전원 케이블 XLPE 단열 3 코어 21/35kV

Copper Wire Screen Medium Voltage Cable XLPE Insulted Three Core 21/35kV Application Medium voltage power cable for static application in ground, within and outside facilities, outdoor, in cable canals,in water, in conditions where cables are not exposed to heavier mechanical stress and tensile strain. Construction C onductor : Stranded copper or aluminum conductor shield :: Extruded semi-conductive compound I nsulation : Cross-linked polyethylene (xlpe) I nsulation shield :