armoured power cable
"
Cáp điện cách điện PVC, Bọc thép băng, Dây điện bọc PVC
PVC Insulated Power Cable Steel Tape Wire Armoured PVC Sheathed Electrical Power Wire APPLICATION This product is suitable for rated voltage not exceeding 0.6/1kV . In the line, for transmission and distribution of energy. CONSTRUCTION Conductor: Class 1/ Class 2 stranded Copper conductor Insulation: Polyvinyl chloride (PVC) Filler ( options) : Polypropylene mesh tearing rope I nner sheath: Polyvinyl chloride (PVC) A rmour: Stainless steel tape( single core ) galvanized steel
MV Steel Wire Armoured Cable CU/XLPE/CTS/STA/PVC Flame-retardant Power Cable
MV Steel Wire Armoured Cable CU/XLPE/CTS/STA/PVC Flame-retardant Power Cable APPLICATION Industrial & Utility Power Distribution Underground & Trench Laying Flame-Retardant Environments High-Temperature & Corrosive Conditions Medium-Voltage Networks (Up to 35kV) CONSUCTRUCTION Conductor: Compacted conductors Conductor Shield: Semi conductive shielding material (below 500mm 2 ) Semi conductive tape+semi conductive shielding material (500 mm 2 and above) Insulation:
IEC 60502-2 XLPE Cáp điện chống cháy bằng nhôm cách nhiệt 3X300mm 3X150mm
IEC 60502-2 XLPE Insulated Aluminium Armoured 3X300mm 3X150mm Flame Retardant Power Cable Applications The cables arewidely used in places such as wind farms and solar power stations to meet the power transmission needs of these places Main Technical Properties 1. DC resistance of conductor at 20°C : not exceed ing 0.1 Ω/km; 2. 4h Power Frequency Voltage Test (4U₀) : No breakdown occurred; 3. 50Hz AC Withstand Voltage Test: 65 kV for 30 min ; No breakdown occurred; 4.
3.6/6kV26/35kV Cáp điện áp trung bình XLPE băng kim loại cách nhiệt Cáp điện bọc thép
3.6/6kV~26/35kV Medium Voltage Cable XLPE Insulation PVC Sheath Metal Tape Armouring Power Cable Application Suitable for urban underground power grids, power station outgoing lines, internal power supply lines of industrial and mining enterprises, etc. CONSTRUCTION Conductor: Round compacted conductors Conductor Shield: Semi conductive shielding material (below 500mm Semi conductive tape+semi conductive shielding material (500 mm 2 and above) Insulation: Polyvinyl chloride
YJLHV62 YJLHV22-18/30kV Luminum Alloy Conductor XLPE Insulation PVC Sheath Metal Tape Bọc thép Cáp điện
YJLHV62 YJLHV22-18/30kV luminium Alloy Conductor XLPE Insulation PVC Sheath Metal Tape Armouring Power Cable Application The AA-8000 series aluminum alloy cables (e.g., AA-8030, AA-8176) are widely used in electrical systems due to their lightweight, cost-efficiency, and superior mechanical/electrical performance compared to pure aluminum. 1. Power Distribution Building Wiring: Branch circuits, feeders, and service entrance cables (NEC Article 310 compliant). Utility Grids:
Cáp điện lực chống cháy bọc giáp dây nhôm AWA CU/XLPE/CTS/AWA
AWA Aluminium Wire Armored Flame-retardant Power Cable CU/XLPE/CTS/AWA APPLICATION Industrial Power Networks: Suitable for factories, mining sites, and heavy machinery due to its armored design (AWA) and flame-retardant properties Commercial Buildings: Ensures safe power transmission in shopping malls, hospitals, and high-rises, where fire safety is critical Harsh Environments: Resists physical damage and moisture, making it ideal for outdoor installations or areas with
MV AWA Cáp điện bọc thép 3.6/6kV26/35kV AL/XLPE/AWA/SWA/LSZH Độ dài tùy chỉnh
MV AWA Armoured Electrical Cable 3.6/6kV~26/35kV AL/XLPE/AWA/ SWA/LSZH Customized Length APPLICATION Widely used in industrial power grids, energy infrastructure, underground substations, and cross-border power engineering projects CONSTRUCTION Conductor : Aluminium Insulation :XLPE Filler : LSZH Armour :Single core: AWA (Aluminium wire armour) All other sizes: SWA (Galvanized round steel wire) Sheath : LSZH STANDARD EN 60502-2 CHARACTERISTICS Voltage Rating Uo/U: 3. 8 /6 .6
Cáp điện lực có vỏ bọc chống cháy AWA 26/35kV CU/XLPE/AWA/PVC/PE
26/35kV AWA Armoured Cable CU/XLPE/AWA/PVC/PE Sheathed Flame-retardant Power Cable Application The 26/35kV AWA (Aluminium Wire Armoured) copper conductor power cable is designed for medium voltage power transmission and distribution systems up to 35kV. It is widely used in applications requiring high reliability, mechanical protection, and fire safety performance. Main Construction Conductor: Compacted conductors Insulation: PVC Metal Screen: Copper Tape Armouring: Aluminium
Đồng nhôm dẫn điện cáp điện XLPE cách nhiệt PVC vỏ băng kim loại đeo giáp
Aluminium Alloy Conductor Cable XLPE Insulation PVC Sheath Metal Tape Armouring Power Cable Application Aluminum alloy cables are widely utilized in various industries due to their lightweight, cost-effectiveness, corrosion resistance, and excellent electrical conductivity. Construction Conductor: AA-8000 Series AL-Alloy Conductor Shield Insulation Binder Tape Outer sheath: PVC Specification YJLHV62 YJLHV22-18/30kV C able S tructure P arameters Specs mm² Conductor diameter mm